Indian Oil Corporation Limited Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.
Indian Oil Corporation Limited - IOCL Tender
Civil And Construction
Eprocure
Opening Date13 Sep 2024
Closing Date27 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 7,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Supply, Installation, Testing And Commissioning Of High Mast Tower, Cctv Camera And Boundary Fencing On Additional Land At Serpl, Raipur
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ERBBS_180520_1Tender No
SERPL/BBS/TS/2024-25/040Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Bidders_help_Document_for_Preferencial_ Bidding_20230207_v1
Special_Instructions_to_the_Bidders_20230207_version_1a
BOQ Items
1:2:4 (Coarse Sand & Aggregate-20mm)1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
5
9064
7682.17
RCC Pipes (NP-3 Class, MD): Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
-
-
-
450mm dia RCC pipes450 mm dia R.C.C. pipes
12
3103
2629.79
Excavation over areas: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed by the Engineer-in-Charge :
-
-
-
In all kinds of soilIn all kinds of soil
1000
242
205.79
Precast RCC Elements: Casting, supplying and erecting in position precast reinforced cement concrete elements (with proper lifting lugs) for trench & drain covers, shelves, partitions, post, slabs etc. for all leads and levels including making necessary moulds, vibrating, tamping, curing, finishing the top surface with cement mortar 1:3 (1 cement : 3 fine sand) to give a smooth and even surface, transportation to Site, aligning and fixing in position with cement mortar 1:3 (1 cem ent: 3 find sand,) including making recess in brick wall for placing the precast element in position and making good the same etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. [Note: Payment for Reinforcement shall be made as per relevant item of SOR.] :
-
-
-
With cement concrete 1:1.5:3With cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 10 mm nominal size
52
21192
17960.05
Reinforcement for RCC-Above Plinth Level: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level :
-
-
-
TMT Bars (Fe-500D grade or more)Thermo-Mechanically Treated bars of grade Fe-500 D or more
3017
111
94.49
Steel work (single section) with epoxy paint Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint "EPILUX 155" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer’s recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work).
0.5
150960
127932.37
G.I. Barbed Wire Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 Kg/100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. [Notes: (1) Cost of posts, struts, earth work and concrete work to be paid for separately. (2) Payment to be made per metre cost of total length of barbed wire used].
2000
25
21.56
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, up to 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per the directions of Engineer-in-Charge, with reinforced barbed tape (R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre. [Note: Cost of M.S. angle, C.C. blocks shall be paid separately].
420
388
329.07
SITC of CCTV Camera
-
-
-
Day-Night Colour IP PTZ Dome Camera with 25X to 35X Optical Zoom, minimum 10X Digital Zoom alongwith IP 66 weatherproof , industrial grade power supply, camera interfacing junction box as applicable, lightning & surge protection and suitable mount complete with cables, connectors, required interfaces etc. as per tender specifications.
1
157015
133063.86
CCTV Armored Cat 6 UTP Networking Cable as per specifications
100
79
67.45
SITC of Highmast
-
-
-
Supply of high mast tower as per technical specification enclosed IOCL-PL-PJ-ELEC-HMT-1.0. The job includes supply of (1) 30 m/20 m high mast structure with lantern carriage with raising/lowering mechanism by FLP motor, minimum steel plate sheet thickness shall be 5 mm. (2) LED flood light fixtures & lamps- 350 W (120 Lumens/W min. efficiency) - 12 nos. & LED Aviation obstruction lights - 02 n os. (3) Lightning arrestor-1200 mm length finial (4) FLP feeder pillar board with cables from feeder pillar to base compartment of h igh mast (5) Foundation bolts. The vendor will submit the foundation design based on soil strata (soil report shall be provided by I OCL) of locations. Further vendor shall provide supervision for testing & commissioning of high Mast.High Mast Shaft with cables, FL P/WP motor, cables and accessories - For 20 M Height
1
418410
354584.78
Erection, Installation,Testing & Commissioning of the Owner supplied high mast tower with the help of suitable tools and plants, wir ing of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour. Scope of work shall include erection & installation of high mast tower, cable connections, erecti on & installation of luminaries & aviation lights, lightning finial, all accessories, cables, etc., erection, foundation casting & g routing of owner supplied FLP feeder pillar, end connection termination & laying of Owner supplied cable from feeder pillar to base compartment of high mast complete with all materials and labour as per instruction of Site Engineer/EIC. Earthing works for High Mas t tower including construction of earth pits to be operated in relevant separate item.For 20 M Height High Mast Tower
1
88599
75084.2
Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth complete with all materials and labour as per instruction of Site Engineer/EIC. Design of foundation shall be provided by IOCL. Piling work if required as per soil strata in foundation of high mast is not covered in this scope of work and shall be taken up separately.For 20 M Height High Mast Tower
1
177725
150614.55
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overal l sheathed, Stranded, FRLSH, C2, Smoke density40% AL,3.5CX25 mm²,A2XFY
250
146
124.22
Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable r acks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and install ation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the co nduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tool s, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engin eer / Engineer-in-Charge: Power cables LT : OD upto 20 mm
250
41
35.3
Evaluation Notes How It Works ?