Tourism Department Tender

View complete overview of Chandigarh DTCA Tender

Tourism Department - DTCA Tender

Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Mar 2023
Closing Date20 Mar 2023
Tender Amount₹ 87,63,289 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 2,29,000
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 2,360

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of following minimum capacity 4-way flow VRF/VRV Cassette Type Indoor ceiling mounted units equipped with synthetic washable media pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control & Occupancy/Human sensor. The indoor Units shall have automatic force shut provision in case of fire on receiving signal from BMS/fire alarm or key card adaptor. The unit price also includes the Refrigerant Piping Y-Joints or Headers as required to connect the above outdoor units with indoor units. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 Degree C WB temperature. Approved Make : O General, Mitsubishi Electric, Daikin, Toshiba & Hitachi.

-

-

-

... More
4.63 TR Ceiling Mounted Cassette Type VRV

2

131768

65884

... More
4.13 TR Ceiling Mounted Cassette Type VRV

2

126368

63184

... More
3.3 TR Ceiling Mounted Cassette Type VRV

8

496216

62027

... More
2.65 TR Ceiling Mounted Cassette Type VRV

9

548523

60947

... More
2 TR Ceiling Mounted Cassette Type VRV

8

444368

55546

... More
1.6 TR Ceiling Mounted Cassette Type VRV

8

435112

54389

... More
1.2 TR Ceiling Mounted Cassette Type VRV

3

158769

52923

... More
1 TR Ceiling Mounted Cassette Type VRV

2

99830

49915

... More
0.8 TR Ceiling Mounted Cassette Type VRV

3

134469

44823

... More
Supply of Centrailsed Controller for controlling the indoor units. Approved Make : O General, Mitsubishi Electric, Daikin, Toshiba & Hitachi.

1

23383

23383

... More
SITC of Non VRF/VRV Split unit 2.2 TR inverter type 5 star energy rating including outdoor Floor/Wall stand. Approved Make O General, Mitsubishi Electric, Daikin & Hitachi.

2

125308

62654

... More
SITC of Sequence timer for Non VRV split AC.

1

11199

11199

... More
Installation, testing & Commissioning of following minimum capacity 4-way flow VRF/VRV Cassette Type Indoor ceiling mounted units equipped with synthetic washable media pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control & Occupancy/Human sensor. The indoor Units shall have automatic force shut provision in case of fire on receiving signal from BMS/fire alarm or key card adaptor. The unit price also includes the Refrigerant Piping Y-Joints or Headers as required to connect the above outdoor units with indoor units. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 Degree C WB temperature. Approved Make : O General, Mitsubishi Electric, Daikin, Toshiba & Hitachi.

-

-

-

... More
0.8 TR Ceiling Mounted Cassette Type VRV

3

11199

3733

... More
1 TR Ceiling Mounted Cassette Type VRV

2

7466

3733

... More
1.2 TR Ceiling Mounted Cassette Type VRV

3

11199

3733

... More
1.6 TR Ceiling Mounted Cassette Type VRV

8

34840

4355

... More
2 TR Ceiling Mounted Cassette Type VRV

8

34840

4355

... More
2.65 TR Ceiling Mounted Cassette Type VRV

9

39195

4355

... More
3.3 TR Ceiling Mounted Cassette Type VRV

8

39816

4977

... More
4.13 TR Ceiling Mounted Cassette Type VRV

2

9954

4977

... More
4.63 TR Ceiling Mounted Cassette Type VRV

2

11198

5599

... More
Remote Controller

-

-

-

... More
Installation , testing and commissioning of corded remote controller suitable for Indoor units and suitable to work on single phase 230 volt (+)(-) 10% 50 Hz AC supply.

25

46650

1866

... More
Installation , testing and commissioning of centralized remote controller.

1

11199

11199

... More
Installation , testing and commissioning of imported Y-joints fittings and header to all indoor units at all floors including alignments of joints complete as required.

42

78372

1866

... More
installation, testing & commissioning of Outdoor Unit - 120 HP including Lifting, shifting, positioning, vaccumising.

1

253841

253841

... More
GAS CHARGING of full VRV/VRF system with R-410 Gas.

1

54128

54128

... More
Refrigerant Piping:- SITC of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported-(Makes:MANDEV/MEXFLOW/RR SHRAMIK)

-

-

-

... More
41.3 mm O.D. (insulation : 19mm)

45

156240

3472

... More
38.1 mm O.D. (insulation : 19mm)

-

-

2172

... More
34.9 mm O.D. (insulation : 19mm)

80

200720

2509

... More
31.8 mm O.D. (insulation : 19mm)

-

-

1528

... More
28.6 mm O.D. (insulation : 19 mm)

145

248095

1711

... More
25.4 mm O.D. (insulation : 19 mm)

-

-

1101

... More
22.2 mm O.D. (insulation : 13 mm)

70

92610

1323

... More
19.1 mm O.D. (insulation : 13 mm)

107

128935

1205

... More
15.9 mm O.D. (insulation : 13 mm)

350

383250

1095

... More
12.7 mm O.D. (insulation :13 mm)

196

158368

808

... More
9.5 mm O.D. (insulation : 13 mm)

310

190960

616

... More
6.4 mm O.D. (insulation : 13 mm)

170

69870

411

... More
Copper piping for split AC

20

22000

1100

... More
Drain Piping:- Providing and laying of rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. (Makes: Diplast/Supreme/Prime)

-

-

-

... More
25 mm dia

340

63580

187

... More
32 mm dia

160

31840

199

... More
Transmission Wiring:- SITC of control cum transmission wiring of 2 core x0.75sq mm copper wire in suitable PVC conduits between indoor & outdoor units. (Makes: Havell's/BCH/Finolex/Polycab)

1450

271150

187

... More
OutdoorUnits Stand -Supply and install the MS Enamel Painted finish MS stand for VRV Outdoor Units.

9

44793

4977

... More
Supply and installation of of GI-Perforated Cable Tray 12 inch for Copper Pipe Supporting from Indoor unit to indoor unit (without cover) including required assessories for installation and finish with enamel paint or dicco paint shade of paint is approved by compitent authority.

580

541140

933

... More
Supply of GI-Perforated Cable Tray 12 inch for Copper Pipe Supporting from Terrace outlet to outdoor unit (with cover). Including required assessories for laying.

10

10950

1095

... More
SUB TOTAL

-

8732846

-

... More
Electrical Pannel

-

-

-

... More
Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55)..Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc..The fabrication should be such that all the member.i.e. vertical/horizontal should be detachable type.i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition..Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work ..Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports..Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator, Neutral failure relay, Time delay relay, surge protection, over voltage relay, etc..Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site..Detail of capacities of MCCB's to be installed in the cubical panel Enclosure as per following:-.LT Panel enclosure having 1No. Incomer MCCB Four Pole 250 Amp. microprocessor type with rotary handle and 8 Nos. outgoing MCCB's 40amp., 2 Nos. 63 amp TPN MCB, 20 Nos. Single pole MCB according to the requirement at site as per entire satisfaction of the engineer-in-charge.

1

150114

150114

... More
Supply Installation Testing & Commissioning of 100 kvar APFC Panel as per entire satisfaction of the engineer-in-charge.

1

100476

100476

... More
Supply and erection of sheet metal busbar chamber with required 400 amp aluminium bus bar. The chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper busbar strips of suitable length and crosssectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site: Bus Bar Chamber 400amp., 415volts Overall Dimensions (610mm x 510mm x 215mm).

1

25000

25000

... More
Supply, laying and erection of Copper conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade to be laid loose in the existing trench or pipe/cable tray as per PWD General Specifications. Overall size 10sq.mm (4Core) Armoured (Loose). Approved makes are Havells, KEI, RR cable, Finolex.

350

367850

1051

... More
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 6 sq.mm (Un-sheathed)

350

24570

70.2

... More
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-

-

-

-

... More
Overall size 2.5sq.mm (50/0.25mm), 3Core

650

64220

98.8

... More
Overall size 4.0sq.mm (84/0.3mm), 3Core

650

95485

146.9

... More
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-

-

-

-

... More
Overall size 95sq.mm (4Core) Un-armoured (Loose)

40

19150

478.75

... More
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-

-

-

-

... More
Medium Gauge PVC Conduit Pipe 20mm dia. (On Surface)

1300

49140

37.8

... More
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-

-

-

-

... More
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with GI. pipe 20mm dia. (A-class),3metre long.

10

80416

8041.6

... More
SUB TOTAL

-

976421

-

... More
CORE CUTTING

-

-

-

... More
Providing the core cutting with 4 inch dia. and making it is good condition after the finish of work.

7000

434000

62

... More
Providing the core cutting with 6 inch dia. and making it is good condition after the finish of work.

4500

301500

67

... More
Providing the core cutting with 8 inch dia. and making it is good condition after the finish of work.

4500

391500

87

... More
SUB TOTAL

-

1127000

-

... More
TOTAL (1 + 2 + 3 )

-

10836267

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.