Municipal Corporation Tender
View complete overview of Chandigarh Municipal Corporation Tender
Municipal Corporation Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Jul 2024
Closing Date7 Aug 2024
Tender Amount₹ 5,75,131
Costs
EMD
₹ 11,503Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MCC_81546_1Bid Award Id
ViewTender No
63/E/MCC/2024Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://http://mcchandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and Fixing Voltage stabilizer 4 KVA for AC upto 1.50 TR with MCB, TDR volt meter copper winding input range 180–250-volt single phase including cost of copper wire from stabilizer to A.C unit with M.S body of 22 gauge sheet powder coated. Make DEOL/Jewel/V-guard.
2
8666
4333
Providing and fixing of 28 gauge copper piping between indoor & outdoor unit complete with sleeve type Kini insulation including the cost of chasing of brick wall, RCC & repairing the same in good conditions as per site requirement to the size & design of manufacture.size of copper pipe 5/8"x3/8".
95
110865
1167
Providing & Fixing PVC rigid drain pipe 20mm (3/4") dia of Diplast/ finolex/supreme make of complete in all respects from indoor unit to disposal points as directed by EIC.
105
16905
161
Supplying and Erection of DP 32 amps. rating, 240 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles alongwith enclosure MCB DB complete with connections, testing & commissioning etc. as required Double Pole 32 Amps L&T/Havells/ABB Make.
5
2765
553
S/I/T/C of 3 Core 2.5 Sq. mm copper conduuctor wire make Finolex/ Havells/ Kalinga/BCH complete in all respect to the entire satisfaction of Engineer in charge.
110
8030
73
P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) recess/ surface type including driver with system Lumens 3600-4000 Im having efficacy of minimum 100 lm/W. THD 10%, PF 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Havells/ Surya/Philips/Wipro/ Twinkle alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 5 years of installations.
8
23496
2937
Supply & Erection of 1x18 watt retrofit LED tube rod with batten Supply & Erection of 1x18 watt retrofit LED tube rod with batten made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should be Phillips/ GE/ Surya/Osram/ Twinkle. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
10
8810
881
S/E of Ceiling Fans 1400mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Usha/ Bajaj/ Khaitan including making connection with 23/.076' flexible wire to be adjacent fan point with regulator . The work shall be executed to the entire satisfaction of Engineer in charge.
4
10332
2583
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. ISI marked
-
-
-
3 x 1.5 sq. mm
35
1820
52
3 Core 2.5 Sq. mm Wire
40
2920
73
3 Core 4 Sq. mm Wire
30
3420
114
Supplying and fixing of following size of PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size 25mm
20
1620
81
Supply & erection of Exhaust Fan (heavy duty12” sweep (300mm) 900 RPM of Bajaj/Usha/Khaitan/Havells make complete with motor blades along with louver to be installed on existing hole in wall/glazing with suitable arrangement. The rate includes cost of all labour,carriage to site, testing, commissioning of Exhaust fan & connection to existing light panel. The job shall be executed to the entire satisfaction of Engineer-in-charge.
2
6282
3141
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per existing model of modular plate.
-
-
-
15/16 amps switch outlet
7
980
140
3 pin 5/6 amp socket outlet
5
560
112
15/16 amps socket outlet
7
1267
181
3 pin 5/6 amp switch outlet
25
1950
78
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
8
2688
336
Supplying and fixing brass batten/ angle holder including connection etc. as required.
5
530
106
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2
2348
1174
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
8
1528
191
Providing and fixing 63 Amps, Ics=100% Icu at 415 V 20 KA MCCB Complete With Connections Testing and Commissioning Etc complete to the entire satisfaction of Engineer-in-charge. The MCCB is to be fixed inside the existing Distribution Box. Make: Havells/ABB/ Schneider/L&T
1
4200
4200
Providing and fixing 100 Amps, Ics=100% Icu at 415 V 20 KA MCCB Complete With Connections Testing and Commissioning Etc complete to the entire satisfaction of Engineer-in-charge. The MCCB is to be fixed inside the existing Distribution Box. Make: Havells/ABB/ Schneider/L&T
1
4601
4601
Erection of LED Street Light/ Flood Light/ Globe Light on wall/poles complete in all respect to the entire satisfaction of Engineer-in-charge.
10
1470
147
Evaluation Notes How It Works ?