Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Jun 2024
Closing Date3 Sep 2024
Tender Amount₹ 39,84,000
Costs
EMD
₹ 79,680Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_662587_1Bid Award Id
ViewTender No
CWE/CHD-42/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and as directed by Engneer-in-charge.
270
-
-
Removal of surplus excavated spoil (Soils) not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
180
-
-
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables as specified in SSR Part-I in trenches/ ducts for cable protection complete all as specified and directed by Engineer-in-Charge.
Note:- Only punned thickness shall be measured and paid.
98
-
-
Supplying & Laying un-reinforced, precast concrete cable protection cover of class HV, type I, flat of size 300mm x 180mm x 40mm, factory made, complete all as specified and directed by Engineer-in-Charge.
6000
-
-
Relaying PCC cable cover/ bricks retrieved from item No 01 here-in-before for cable protection complete all as specified and directed by Engineer-in-Charge.
500
-
-
Taking down exiting unserviceable PCC pole of any description and setting aside, complete all as specified and directed by Engineer-in-Charge.
5
-
-
Dismantling of ACSR or AAC conductors and setting aside at place as directed by Engineer-in-Charge for resue or issue under sch of credit complete all as specified and directed by Engineer-in-Charge.
5
-
-
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use within 50m for reuse or issue under schedule of credit complete all as specified and directed by Engineer-in-Charge.
5
-
-
Dismantling insulators any type, any size complete all as specified and directed by Engineer-in-Charge.
30
-
-
Dismantling stay assembly complete incl demolition of concrete, etc. complete all as specified and directed by Engineer-in-Charge.
5
-
-
Dismantling & taking down of existing worn out/ unserviceable GI wire of any description/ size & in any position from existing HT Lines including cradle guard wires complete all as specified and directed by Engineer-in-Charge.
0.5
-
-
Dismantling air break gang operated switches vertical/ horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/ worn out components and insulators etc. complete all as specified and directed by Engineer-in-Charge.
10
-
-
Disconnecting & taking out old existing serviceable HT cable of size upto 120 Sqmm 3 core of any description and in any position from trench/ duct and stacking properly for relaying after repairing and making joints etc. or issue under schedule of credit, complete all as specified and directed by Engineer-in-Charge.
1200
-
-
Fixing only old serviceable cross arm of MS channel or angle section dismantled under item Ser No 10.00 here-in-before complete including preparation of surface and painting with two coats of synthetic enamelled paint complete all as specified and directed by Engineer-in-Charge.
0.5
-
-
Fixing only old serviceable insulators dismantled under Serial item ser No 11.00 here-in-before complete all as specified and directed by Engineer-in-Charge.
8
-
-
Fixing only of old serviceable aluminium conductor, steel reinforced (ACSR) retrived from item No 09.00 here-in-before of any size/ description on HT poles/ lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified and directed by Engineer-in-Charge.
0.5
-
-
Supply, laying, jointing and testing 11 KV (Earthed), aluminium conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having cross sectional area 120 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
Note :- Earth work, sand cushioning, pipe and PCC cable protection cover shall be measured and paid separately.
400
-
-
All as per serial Item No.19 here-in-before but cable of size 95 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge.
400
-
-
Relaying only old existing serviceable HT cable retrieved from item No 15.00 here-in-before of size upto 120 Sqmm 3 core in any position after repairing and making joints etc. complete all as specified and directed by Engineer-in-Charge.
100
-
-
Supply, jointing and testing of cable jointing kit of 11 KV grade cable for indoor end termination, Heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm. including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
5
-
-
Supply, jointing and testing cable jointing kit of 11 KV grade cable for outdoor end termination, Heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
5
-
-
Supply, jointing and testing cable jointing kit of 11 KV grade cable for indoor end termination, Heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 Sqmm including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
5
-
-
Supply, jointing and testing cable jointing kit of 11 KV grade cable for outdoor end termination, Heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
5
-
-
Supply, jointing and testing cable jointing kit of 11 KV grade cable for straight through, Heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
3
-
-
Supply, jointing and testing cable jointing kit of 11 KV grade cable for straight through, heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 Sqmm including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and fixing for cable route indicator for HT 11 KV cable of size 4" dia Cast Iron Round plate not less than 2.5 mm thick with stand of angle Iron duly marked with HT 11 KV/ MES including necessary PCC work for fixing complete all as specified and directed by Engineer-in-Charge.
100
-
-
Supply and fixing on HT pole danger notice plate for HT 11KV/ 33KV of size 25 cm x 20 cm, 1.6mm thick mild steel sheet vitreous enamelled, white with letters, figure and conventional skull & bones “DANGER” etc. in signal red colour and fixed with MS clamps made out of 25mm x 3mm MS flat iron, nut, bolts complete all as specified and directed by Engineer-in-Charge.
50
-
-
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP–55), 11 metre long, complete with cast iron base plate, pole cap/ finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal welded throughout entire length of pole with and including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
5
-
-
Note:- Earthwork, PCC work in foundation & coping of pole, Cross arms, danger notice board and anti climbing device shall be measured and paid separately.
-
-
-
Material & labour for fabrication of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, driling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of synthetic enamel paint over one coat of primer complete all as specified and directed by Engineer-in-Charge.
5
-
-
Material and labour for anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed by Engineer-in-Charge.
1
-
-
Material and labour for HT 11 KV grade insulation sleeve 20 mm dia heat shrinkable type complete all as specified and directed by Engineer-in-Charge.
50
-
-
Supply and fixing pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 150 mm height and 150 mm dia suitable for working pressure upto and including 11000 volts grade for HT lines fixed on poles complete all as specified and directed by Engineer-in-Charge.
10
-
-
Supply and Fixing disc type insulator, porcelain, vitreous 145 mm height and 225 mm dia ball and socket type white/ brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts grade for HT lines fixed on poles complete all as specified and directed.
20
-
-
Deployment of manpower/ tools etc for Re-stretching / refixing the existing LT/HT OH Lines of existing ACSR conductor of any type and size including disconnecting binding wire on insulator, rebinding properly to avoid tension/ fitting bending of poles, complete all as specified and directed by Engineer-in-Charge. Note : Four lines of conductor will be considered as one RM length.
2000
-
-
Triming of tree branches and making clearances from electric lines and poles ACSR conductors approx 10 mtrs from electric lines complete all as specified and directed by Engineer-in-Charge.
3000
-
-
Supply and fixing of aluminium conductor, steel reinforced (ACSR) of any size/ description on HT poles/ lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified and directed by Engineer-in-Charge.
1
-
-
Supplying, stringing and fixing GI continuous GI earth wire of size 4 mm/ 3.15 mm dia on HT poles as in cradle guards/ earth wires etc complete all as specified and directed by Engineer-in-Charge.
0.5
-
-
Supply, installation and testing of 11 KV outdoor type, gang operated Air-break switch, triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with suitable dia of GI pipe (Medium grade) operating rod of suitable length with an ON-OFF position capacity 200 amps with dropout fuse & 12 insulator connected with new ACSR conductor (jumper) duly Logged incoming and out going with Steel nut bolts and washers including taking down of old unserviceable air break switch complete all as specified and directed by Engineer-in-Charge.
5
-
-
M&L for servicing of the outdoor type HT 11 KV, 200 amps/ 400 amps capacity gang operated air break switch mounted on HT two pole/ four pole structure by properly adjusting the mountings for ON/ OFF operation by working from ground level, adjusting the length of operation rod, lubricating the moving parts, tightening of all nuts/ bolts, checking of all jumper connections for proper contact of male/ female contacts, replacing worn out spares refixing in position & testing to check the system on full load complete all as specified and as directed by Engineer-in-charge.
5
-
-
Note :- (a) Contractor should visit the site to asses the repair involved before quoting the rate.
(b) Spares/ material required in repair will be masured & paid separately under relevant item as the supply only.
-
-
-
Supply only post top insulator suitable for 11 KV Air break switch 11 KV Drop out fuse refixing in position & testing to check the system on full load complete all as specified and as directed by Engineer-in-charge.
20
-
-
Suppy only Tinned copper flexible strip (Jumper) suiatble for 11 KV Air break Switch complete all as specified and as directed by Engineer-in-charge.
50
-
-
Supply only male contact for 11 KV Air break switch complete all as specified and as directed by Engineer-in-charge.
50
-
-
Supply only female contact for 11 KV Air break switch complete all as specified and as directed by Engineer-in-charge.
50
-
-
Supply only MS Strip operating mechanism (Jumper Carrier) for GOD insulator complete all as specified and as directed by Engineer-in-charge.
20
-
-
Supply only terminal clamp suitable for 11 KV out door AB switch complete all as specified and as directed by Engineer-in-charge.
20
-
-
Supply and fixing MS sheet 5 mm thick for transformer HT/ LT side cable box cover, including cutting as per site requirement, drilling, welding, painting with two coats of synthetic enamelled paint over a coat of primer complete all as specified and as directed by Engineer-in-charge.
50
-
-
Note:
MS box, cover shall be provided with PU gasket and suitable size cable gland to ensure IP 66 protection. Rate quoted shall be deemed to be inclusive of the said provision.
-
-
-
S&F Mild steel, screw bolt machine made with hexagonal or square heads at one end and screwed the other end with washer and one hexagonal or square nut exc 5 cm and n exc 10 cm long and 5 to 10 mm dia complete all as specified and as directed by Engineer-in-charge.
10
-
-
Supply and fixing in repair Lightening arrester, single pole, zinc oxide (Gap less) surge type suitable for use in effectively earthed system with nominal voltage 12 KV and shall comply with IS : 3070 (part -3) 1993 complete all as specified and as directed by Engineer-in-charge.
10
-
-
Material and labour for stay assembly for HT poles comprising of 20mm dia, 2.15 mtr long galvanized stay rod, having 7/ 3.15mm GI stay wire stranded and 300 mm X 500 mm X 6 mm thick MS stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/ accessories like loop type insulator overall dimensions 90 mm x 140 mm, clearance of hole 25.5 mm, shackle & stay clamps made out of 50 x 6mm MS flat iron, necessary excavation and earth work in soft/ loose soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
10
-
-
Note:- Cost of excavation and earth work in soft/ loose soil and PCC work in 1:3:6 type C-2 (using 40mm graded curshed stone aggregate) shall deemed to be included in quoted rate.
-
-
-
Material and labour for cleaning and preparation of all existing steel surfaces of steel tubular poles 11 mtrs long for painting including mild steel cross arms, clamps and street light brackets, MS boxes etc and applying one coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 metre from the plinth of the pole and applying one coat of synthetic enamelled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of pole including writing pole No and other sign works with white paint over black painted base in the pattern and style as approved by the Engineer-in-Charge complete all as specified & directed. Note:- Size of black painted base for numbering shall be 100 mm x 25 mm and the size of numbers shall not be exceeding 10 cm height.
25
-
-
All as per Item No. 53.00 here-in-before but double pole (Two pole structure) complete all as specified and as directed by Engineer-in-charge.
10
-
-
All as per Item No. 53.00 here-in-before but four pole (Four pole structure) complete all as specified and as directed by Engineer-in-charge.
2
-
-
Disconnecting and taking out old existing unserviceable/ corroded GI tubing 100mm bore of any description and Supplying, laying & jointing GI tubing, 100 mm bore, Light grade, as in sleeving etc laid in trenches/ ducts/ horizontal bore hole complete all as specified and directed by Engineer-in-Charge.
40
-
-
All as per Serial Item No. 56.00 here-in-before but of size 80 mm bore complete all as specified and as directed by Engineer-in-charge.
40
-
-
Material & Labour for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) for foundation of the pole including necessary form work complete all as specified and as directed by Engineer-in-charge.
4
-
-
Material & Labour for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) for coping of the pole including necessary form work complete all as specified and as directed by Engineer-in-charge.
2
-
-
Material & Labour for cement concrete, 100 mm thick Type D-2, 1:4:8 (40 mm graded stone aggregate) as in path for installations incl demolition of existing PCC complete all as specified and as directed by Engineer-in-charge.
200
-
-
Material & labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for inserting of pipe upto 100 mm diea bore complete all as specified and as directed by Engineer-in-charge.
100
-
-
Note 1. Length of bore hole under road/ pavement shall be as per site reqirement.
2. GI pipe shall be measured and paid separately under respetive items.
-
-
-
Material and labour for taking out old exhausted/ unusable silica gel from the silica gel container and filling new silica gel complete all as specified and as directed by Engineer-in-charge.
10
-
-
Material and Labour for Testing of transformer oil before and after dehyderation and filteration of transformer oil, installed in different sites for its dielectric strength and submitting the test report to the department complete all as specified and as directed by Engineer-in-charge.
20
-
-
Disconnecting defective outdoor/ indoor power distribution transformer of capacity 50 KVA to upto and including 200 KVA from HT/ LT sides draining out complete transformer oil & storing the same in suitable containers (to be arranged by contractor ) opening the top cover and lifting up the core assembly carefully to check the condition of transformer winding core retanking the same after repair refilling the transformer oil after dehydration and filteration (dehydration and filteration to be paid separately) including checking of leakage of transformer body and welding works required for making transformer body leak proof transportation of transformer to and from site to work shop and re-installation the same at any site complete all as specified and as directed by Engineer-in-charge.
Note :- Dehydration and filtration and topping up of transformer oil shall be measured and paid separately under respective items.
1
-
-
All as per serial Item No 63.00 here-in-before but transformers of cap 250 KVA to 500 KVA.
1
-
-
Material & Labour for replacement of burnt/ defective HT copper coil with new one made out of super enamelled heavy duty copper wires of size matching to the existing one including varnishing, drying and insulating material in transformer complete all as specified and as directed by Engineer-in-charge.
150
-
-
All as per Serial Item No. 65.00 here-in-before but LT copper coil complete all as specified and as directed by Engineer-in-charge.
50
-
-
Replacement of existing defective HT tap changer of suitable size with tapping arrangement 2.5% to 7.5% and one normal tapping including connecting up with HT coil and testing of transformer capacity up to 200 KVA complete all as specified and as directed by Engineer-in-charge.
1
-
-
All as per Serial Item No. 67.00 here-in-before but Tap Changer for 250 KVA to 500 KVA complete all as specified and as directed by Engineer-in-charge.
2
-
-
Material & Labour for replacement of synthetic rubberised cork sheet gasket 1/4" thick suitable for main body top cover of transformer of capacity up to 200 KVA complete all as specified and as directed by Engineer-in-charge.
4
-
-
All as per Serial Item No. 69.00 here-in-before but cork sheet gasket for 250 KVA to 500 KVA complete all as specified and as directed by Engineer-in-charge.
3
-
-
Material & Labour for replacement of defective/ cracked HT porcelain bushing (set of three) of suitable size for transformer upto 200 KVA including washers of good quality complete all as specified and as directed by Engineer-in-charge.
8
-
-
All as per item serial Item No. 71.00 here-in-before but HT porcelain bushing for 250 KVA to 500 KVA complete all as specified and as directed by Engineer-in-charge.
3
-
-
Material & Labour for replacement of defective/ cracked LT porcelain bushing (set of four) of suitable size of transformer upto 200 KVA including washers of good quality complete all as specified and as directed by Engineer-in-charge.
7
-
-
All as per Serial Item No. 73.00 here-in-before but LT porcelain bushing for 250 KVA to 500 KVA complete all as specified and as directed by Engineer-in-charge.
3
-
-
Supply and fix in repair HT bush rod, made out of brass with brass nuts and washers of required length and dia (as per existing) including connecting up with HT coil of transformer upto 200 KVA complete all as specified and as directed by Engineer-in-charge.
6
-
-
All as per item serial Item No 75.00 here-in-before but HT bush rod for 250 KVA to 500 KVA complete all as specified and as directed by Engineer-in-charge.
6
-
-
Supply and fix in repair LT bush rod, made out of brass with brass nuts and washers of required length including and dia (as per existing) connecting up with LT coil of transformer upto 200 KVA complete all as specified and as directed by Engineer-in-charge.
6
-
-
Supply and fix in repair LT bush rod, made out of brass with brass nuts and washers of required length including and dia (as per existing) connecting up with LT coil of transformer of capacity 250KVA and upto 500 KVA complete all as specified and as directed by Engineer-in-charge.
6
-
-
Supply and fix in repair breather with transparent body of suitable size duly filled with fresh silica gel complete for transformers of cap 250 KVA upto 500 KVA complete all as specified and as directed by Engineer-in-charge.
6
-
-
Supply and fix in repair breather with transparent body of suitable size duly filled with fresh silica gel complete for transformers of cap upto 200 KVA complete all as specified and as directed by Engineer-in-charge.
5
-
-
Taking down silica gel container from transformer and heating the silica gel at sufficient temperature to remove the moisture from it including refixing the same as per position complete all as specified and as directed by Engineer-in-charge.
6
-
-
Deployment of manpower/ tools/ machinery/ plant for Dehydration/ filtration of transformer oil of voltage grade 11/ 0.433 KV of transformers, of various capacities installed at different locations by disconnecting plants electrically for recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength achieves to min 50 kV when measured at 2.5 mm gap to bring the acidity within the permissible limit complete all as specified and as directed by Engineer-in-charge.
6500
-
-
Note:- (a) Filtration/ dehydration of transformer oil shall be carried out at the location where transformer is installed with trolley mounted filtration plant and necessary filter/ dehydration plant having pressure gauge, hour meter, temperature gauge to be brought at site by the contractor including electric supply arrangement to run the dehydration equipment and rate deemed to be included in the quoted rate.
-
-
-
M&L for topping up/ replacement of old transformer oil with new transformer oil suitable for working voltage 11000 volts grade conforming to relevent IS-335 (Transformer oil to be supplied in sealed container) complete all as specified and as directed by Engineer-in-charge. Note :- New transformer oil to be brought in company sealed ISI marked container with test certificate.
650
-
-
Material and Labour for painting of transformer upto 200 KVA capacity with good quality synthetic enamelled paint using spray gun with compressed air on complete external portion of transformer including preparation of surface by scrubbing, cleaning ,stains greasy spots, dusts etc, The painting of transformer shall be carried out in situ i.e. on four pole structure or in sub station at different places including writting SM/ MES number complete all as specified and as directed by Engineer-in-charge.
10
-
-
All as per Serial Item No. 85.00 here-in-before but Painting to transformer of capacity 250 KVA and upto 500 KVA capacity complete all as specified and as directed by Engineer-in-charge.
5
-
-
Material and Labour for repair to arresting of leakage / from worn out spindle (rod)/ bushing/ tap changer etc of any capacity transformer indoor/ outdoor type of any make & model, in position by disconnecting electric connection as required from HT/ LT side cable box or bushing or jumper, opening of top cover with the help of mechanical Machine/ men power, drain out tranformer oil upto required level and to replace worn out spare/ component with new one incuding replacement of UNSV gas kit set of top cover and making necesary inetrnal & external connection, refilling drain out oil etc complete all as specified and as directed by Engineer-in-charge.
4
-
-
All as per Serial Item No 86.00 here-in-before but arresting of oil leakages from body/ tubes fins etc.
Note for item No 87.00 & 88.00:- any spares required will be measured and paid separately under respective items of this schedule.
4
-
-
Supply and fixing of PG clamp suitable for upto 50 Sqmm copper conductor complete all as specified and as directed by Engineer-in-charge.
20
-
-
Material and Labour for disconnecting indoor/ outdoor transformer of capacity 200 KVA to 500 KVA 11KV/430 volts from HT/LT side, lifting the transformer from the existing sub station/ plinth and shifting of transformer to new location not exceeding 750 metre and refixing the transformer at new location and making all the HT/ LT side connections and testing complete all as specified and as directed by Engineer-in-charge.
2
-
-
Note :- cost of Installation of transformer, testing and connecting the both HT & LT cables, commissioning of transformer after checking voltage and loading the transformer at full load all as specified and directed shall be deemed to be included in quoted rates.
-
-
-
Supply, installation, commissioning and testing of indoor epoxy resin type 11 KV current transformer copper wound having ratio of 150-/5A having burden of 10 VA and breaking cap of 18.4 KA for 1.0 second including taking out existing unserviceable current transformer of any description and in any position complete all as specified and as directed by Engineer-in-charge.
3
-
-
Supply, testing and installation Potential transformer copper wound indoor epoxy resin type of ratio √11KV/ √0.433KV and burden of 10 VA including Disconnection of unsv potential transformer from metering box complete all as specified and as directed by Engineer-in-charge.
3
-
-
Supply, installation, commissioning and testing of indoor epoxy type 11 KV current transformer having ratio of 60-5-/5A having protection core class IP10, IL-28/ 75kv burden of 10 VA and breaking cap of 18.4 KA for 1.0 second including disconnection and taking out existing unserviceable current transformer of any description and in any position complete all as specified and as directed by Engineer-in-charge.
3
-
-
All as per Serial Item No. 92.00 here-in-before but Current Tranformer ratio 60-1/1A and 2.5VA complete all as specified and as directed by Engineer-in-charge.
3
-
-
All as per Serial Item No. 92.00 here-in-before but Current Transformer ratio 40-1/1A and 2.5VA complete all as specified and as directed by Engineer-in-charge.
3
-
-
Material & Labour for earthing complete with galvanised steel earth electrode plate of size 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32 x 6mm upto test point with suitable GI nuts/ bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel wire mesh and light grade GI strip protection pipe 40 mm bore up to main board complete as shown in electrical plate No. 3 of MES schedule Part-I 2009, connected to earthing testing point including testing on completion including taking out existing unserviceable earthing any type complete all as specified and as directed by Engineer-in-charge.
12
-
-
Note - (i) The quoted rate shall be deemed to include the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (medium grade) for watering 40mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
(ii) Quoted rates shall be deemed to include for earthing strip with protection pipe up to 7.5 M length.
-
-
-
All as per Serial Item No. 95.00 here-in-before but connected with GI strip 25x4 mm complete all as specified and as directed by Engineer-in-charge.
12
-
-
All as per Serial Item No. 95.00 here-in-before but copper earth plate of size 600mm x 600mm x 3.15 mm and connected with copper strip of size 25 x 3 mm complete all as specified and as directed by Engineer-in-charge.
15
-
-
Taking down unserviceable Earth lead any including Supplying and fixing earth continuity conductor or main earthing lead 32mm X 6mm, GI strip/ earth lead, laid in pipe/ fixed on walls or any other position including jointing by GI nuts, bolts and washers, Insulators at every joint complete all as specified and as directed by Engineer-in-charge.
60
-
-
All as per Serial Item No. 98.00 here-in-before but GI strip of size 25 x 4 mm complete all as specified and as directed by Engineer-in-charge.
60
-
-
All as per Serial Item No. 98.00 here-in-before but copper strip of size 25 x 3 mm complete all as specified and directed.
60
-
-
Supply, Installation, Testing and commissioning of 24 Volt DC, low maintenance type chargeable stationary battery set comprising of 02 Nos, 12 volts each having 180 Amp hour capacity batteries including battery charging set of adequte capacity and control equipment in sheet steel cabinet of 2.0 mm thick floor mounted type suitable for input of 230 volts single phase 50 Hz AC complete with internal & External wiring of all components accessories, all as specified for 11 KV VCB panels, with complete control wiring (for connecting the DC tripping system to HT 11 KV VCB panel board of TOP N AREA complete) wiring shall be of copper conductor single core and size not less than 2.5 Sqmm including disconnectiong and taking out old U/S battery charger complete all as specified and as directed by Engineer-in-charge. Note. Cost of control wiring up to VCB panel shall deemed to be inclusive in quoted rates.
1
-
-
Material & Labour for minor repair like replacement of fuse of suitable capacity, re-stretching, restringing, tightening & jointing of broken HT conductors in routine/ natural calamity to ensure uninterrupted power supply of the HT overhead lines from MRS to various distribution transformers of Tech/ Residential area of DEAL and replacement of spares of VCB’s, etc. complete all as specified and as directed by Engineer-in-charge.
20
-
-
NOTE:-
Replacement of burnt parts (PG Clamp, ACSR Conductor, Fuse wires of suitable capacity, Tripping coil and closing coil, Locking pin, LED type Indicators (Spare parts shall be paid separately under appropriate item of sch ‘A’.
-
-
-
Taking down the existing relays (Three phase over current and earth fault relays) fixed in 11KV HT panels and supply and fixing, and testing self powered Three phase over current and earth fault relays model No M 61A Aux supply 110 volt with (2NO+2NC ) CT rating current 1 Amp to 5 Amp ccomplete all as specified and as directed by Engineer-in-charge.
3
-
-
Material and Labour for locating of HT 11 KV under ground cable fault by providing fault locating machine (hiring of machines) and qualified licence holder Engineers at N area, K Area & Hallomajra Area complete all as specified and as directed by Engineer-in-charge.
2
-
-
Servicing, caliberation and testing of 11 KV, 400 Amps/ 630 Amps VCB/ SF-6 indoor type along with control panel and control wiring protection system and relays by primary & secondary injection system all as directed including testing of battery bank/ battery charges/ DC system, rectification of fault if any complete all as specified and as directed by Engineer-in-charge.
10
-
-
Material and labour for maintenance and servicing of 100 KVA Compact substation MAKE- ABB, by cleaning complete Transformer, HT Input side including replacement of 11KV HT load break switch as per existing, renewal of burnt/ heated thimbles etc, servicing LT side by renewal of all thimbles as per existing size, cleaning the panel with carbon tetra chloride solution, renewal of door hinges and making doors properly operational incuding welding job as required at site all as directed by Engineer in charge.
1
-
-
Disconnecting & taking out non functional VCB of any description and any make of rating 11 KV, 400 Amps/ 630 Amps dismantling/ opening of the VCB for servicing/ overhauling, taking out and removing unserviceable/ defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and its testing complete all as specified and directed by Engineer-in-Charge.
3
-
-
Note:-1. The quoted rates of the contractor shall deemed to be included for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. 2. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only'.
-
-
-
Supply only following spare parts for 11 KV Sub stn and VCB, 800/ 630 Amps capacity indoor type
Note :
(i) Fixing & testing element of following item is deemed to be included under Sch `A’ item No 107 and 108 above. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
-
-
-
Vaccum Interrupter type WL-33379
3
-
-
Charging motor as per Existing Make and specification
3
-
-
Set of 6 Nos flexible connectors
2
-
-
Closing coil assembly 30 Volt to 110 Volt
5
-
-
Tripping coil assembly 30 Volt to 110 Volt
5
-
-
PG Clamp
12
-
-
LED Indicator lamp (RYG) 110 Volt
10
-
-
LED Indicator lamp (RYG) 30 Volt
10
-
-
Heating element with thermostat switch 150 Watt compact type
4
-
-
Operating handle for trolly, lowering/ raising suitable for any capacity of VCB as per sample
2
-
-
Tinned copper fuse wire 18/20 SWG
2
-
-
Gear assembly suitable for VCB 400/ 630 Amp
2
-
-
Material & Labour for Informatory sign board of size 1000mm x 600mm made out of 2mm thick Stainless steel sheet fixed on Stainless steel sheet frame of rectangular hollow section of 45mm x 25mm fixed on stainless steel pipe 50mm dia 2.25mtr long vertical member -2 nos, including letter writing (100 to 150 words), logo/ drawing/ schematic diagram made with computerized printing of fully retro reflective with high intensity prismatic tape pasted on sheet with single side writing including vertical pipe emmebedded in 0.30x0.45mtr in PCC (1:3:6 ) type C-1 including Taking down existing any type of sign board complete all as specified and directed by the Engineer-in-charge
1
-
-
Note :
(i) The cost of Excavation postholes, earth work, PCC for foundation etc shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account.
(ii) The letter size of Main heading shall be minimum100mm x 10mm and sub heading letter size shall be minimum 50mm x 5mm.
(iii) The drawing and colour of writing work shall be got approoved by Engineer in charge.
-
-
-
Material and labour for chemical earthing complete with copper plate electrode 90cm x 60cm x 5mm thick buried diretly in ground earth pit of size 1800 x 900mm and depth of 4500 mm below ground level with top edge of plate not less than 3.750 mtrs surrounded from all side at least 15 cm with packed layer of charcoal dust and common salt in alternate layers of 15 cm and top layer of 150 mm with copper sulphate after charcoal and common salt layer and electrode connetion with copper earth strip of size 25 x 4mm including test point on wall of bld made of copper strip of 32 x 6 mm by means of tinned copper/ brass volts nut, chuck nut and copper washers besides brassing at all joints all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, 40 mm dia GI pipe light grade for protection of earth lead from top of plate to test terminal, 20mm dia GI watering pipe medium grade with funnel wire mesh , PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate as in pit with 25 x 25 x 3 mm mils steel angle iron frame for cover, precast 50mm thick RCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate as in cover, reinforced with 8mm dia TMT Bar @ 100mm C/C both complete as specified and testing on completion.
1
-
-
Note:
(a) Earth electrode to be tested on completion and earth resistance of earth electrode should not be more than 2 ohm.
(b) Unit rate quoted by the contracator are deemed to be included the cost of copper strip 32x6 mm upto test point. (c) protection pipe 40 mm dia GI light grade upto test point from top edge of the electrode.
-
-
-
Supply and fixing in repair Energy Meter tamper proof LED Display with out optical port, single phase, AC 230 Volts 10 to 40 Amps cap in position complete with incoming and outgoing cable connection with suiable size of copper cable and copper lugs complete with tampre proof ploycarbonate enclosure with non breakable glass in front complete all as specified and as directedby Engineer-in-charge.
10
-
-
Material & Labour for Informatory LED Glow sign display board with all necessary electrical wiring and conection with battery back up of 6 hrs of size 2.00 Mtr x 1.20 Mtrs LED display in red colour as (E/M COMPLAINT CELL AGE E/M (CHANDIGARH) duly supported with MS sheet from the back side and stiffened with angle iron of size 25 x 25 x 4mm to withstand wind pressure, LED glow sign board to be fixed on Chromium plated Stainless steel Pipe frame of 50mm Dia, at 2.5 mtr height including taking down old U/S any type of sign board any type and from any position complete all as per ground requirement and as directed by Engr-in-Charge. Note : The cost of Excavation post hole, earth work, PCC for foundation etc shall be deemed to be included in the unit rate of this item, Nothing extra shall be admissible on this account.
1
-
-
Dismantling of old unsv RCC security/ cattle fencing post any type including demolition of PCC from foundations and stacking where directed, complete all as per ground requirement and as directed by Engr-in-Charge.
15
-
-
Material & labour for mild steel work as of posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including painting with two coats of synthetic enamel black paint over one coat of red oxide as primer all as specified and as directed by Engineer-in-charge.
80
-
-
Material and Labour for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including painting with two coats of synthetic enamel black paint over one coat of red oxide as primer all as specified and as directed by Engineer-in-charge.
50
-
-
Material and Labour for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240 complete including painting with two coats of synthetic enamel black paint over one coat of red oxide as primer all as specified and as directed by Engineer-in-charge.
100
-
-
supply and fixing in repair Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
60
-
-
Supply only MS galvanised Chain link fencing conforming to IS-2721- 1979, any size or type complete all as specified and as directed by Engineer-in-Charge.
150
-
-
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed. Note. Weight of chain link fencing shall be ascertained by BOO convened by GE.
70
-
-
Material & Labour for interlocking tiles, factory made, machine pressed, 60mm thick, precast cement concrete (Design Mix M-35 Grade) any colour and shape (confirming to ISI-15658-2006) over and including 50 mm thick sand cushioning and joint filled with sand complete all as specified and directed by Engineer-in-charge including demolition of unserviceable paver block etc. any type all as specified and as directed by Engineer-in-charge.
Note Serviceable interlocking tiles shall be relayed and shall be measured and paid separately.
100
-
-
All as per Serial Item No. 121.00 here-in-before but of 80 mm thick complete all as specified and as directed by Engineer-in-charge.
100
-
-
Material and labour for laying only interlocking tiles 60mm thickness retrieved from Serial Item no 119.00 here-in-before bedded over and including 50 mm thick sand cushioning and joint filled with fine sand complete all as specified and directed.
50
-
-
Supply and fixing in repairs LED type solar street light fitting with following features/specification:- 1. Luminaire:- Aluminium housing LEDs for light source optics with high effeciency driver & MPPT charge controller, Excellent heat dessipation IP-65 protection, High birghtness and high efficiency of more than 120 lm/W new age LEDs, individual peanut optical lenses for uniform light distribution system output: 2200 Lm. 2. Solar Panel:- Polycrystaline solar cells. 3. Battery:- Inbuilt (LiFePO4) 12.8 Volts 40 AH Lithium battery, weather proof, long back-up ideal for cloudy conditions. 4. Pole:- Galvanised pole, Rigid and safe, corrossion free length 6 mtr With optimum thermal management and heat sink design and microprocessor based charge controller and led driver maximizes the performance of panel & battery complete all as specified and directed.
1
-
-
Supply and laying High voltage Insulating electrical mat of thickness 3 mm for system voltage 11 KV and breakdown volatage 65 KV made of elastomeric polymers material having high insulation resistance of size 1Mtr x 5 Mtr complete all as per IS 15652 : 2006.
1
-
-
Servicing of 11 KV load break switch after taking proper shut down and make sure that naional safety norms are followe, Carrying out visual inspection, Inspeting of HT Load break switch cleaning of all movable and fixed parts using vaccuum cleaner, mild alkaline cleaning agent etc all as specified and as directed by Engineer-in-charge.
2
-
-
Laying Only of XLPE insulated, armoured heavy duty, electric cable with stranded aluminum conductor of size 3 core 120 sqmm 11000 volts grade, laying in trenches, passing through pipes, fixed along walls and/ or poles completeall as specified and as directed by Engineer-in-charge. Note:- XLPE cable will be issued free of cost by the department under Schedule B.
200
-
-
Laying Only of XLPE insulated, armoured heavy duty, electric cable with stranded aluminum conductor of size 3 core 95 sqmm 11000 volts grade, laying in trenches, passing through pipes, fixed along walls and/ or poles complete all as specified and as directed by Engineer-in-charge. Note:- XLPE cable will be issued free of cost by the department under Schedule B.
200
-
-