Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Dec 2023
Closing Date20 Jan 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_633216_1Bid Award Id
ViewTender No
GE (AF) MC CHD/T-45/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
One ceiling fan point controlled by one way Modular switch 5 amp and one regulator complete.
20
-
-
One exhaust fan point controlled by one way Modular switch 5 amp complete.
8
-
-
One 3 pin 5 Amps socket point controlled by one Modular switch on same board.
10
-
-
One 3 pin 5 Amps socket point controlled by one Modular switch on independent board.
20
-
-
Material only for Sub Main Wiring with two runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roof with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge.(02 run 6 Sq mm single core cable, one run of 6 Sq mm earth wire & One run of PVC conduit will measured as one RM).
60
-
-
Supply only in replacement ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified.
50
-
-
Supply only in replacement Modular switch 6 Amps single pole one-way, 1 Module complete all as specified.Make SSK/Anchor/Havells.
100
-
-
Supply only in replacement Modular switch 16 Amp single pole one way,1 Module all as specified.
100
-
-
Supply only in replacement Bell Multi Music type, 230 Volts complete with connection all as specified & directed.
26
-
-
Supply only in replacement Modular fan Regulator electronic step type 120watt , 2 Module complete all as specified.
50
-
-
Supply only in replacement Lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified.
20
-
-
Supply only in replacement Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified.
30
-
-
Supply onlly Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified.
100
-
-
Supply and Fixing switch piano flush type 5 Amps single pole one-way, complete all as specified.
30
-
-
Supply only in replacement switch piano flush type 15 Amp single pole one way, all as specified.
50
-
-
Supply only in replacement socket outlet flush type 2-in-1, 3 pins 5 Amps multipurpose complete all as specified.
50
-
-
Supply only in replacement socket outlet flush type 2-in-1,3 and 5 pins 15 Amps multipurpose complete all as specified.
100
-
-
Supply and Fixing Modular bell Push switch flush type 6 Amps single pole one-way complete all as specified.Make SSK/Anchor/Havells.
20
-
-
Supply only in replacement capacitor 2.5 to 3.5 MFD suitable for ceiling fan / exhaust fan complete all as specified and directed.
250
-
-
Supply only in replacement indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 20 watt LED Tube fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, 100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified.
1105
-
-
Supply only in replacement in replacement of Energy saving 20 watts Retro fit LED tube rod T8 1200 mm long complete all as directed by Engineer-in-Charge.
500
-
-
Supply only in replacement of 02 feet10 Watt LED Batten with extruded aluminimum housing with high quality PC diffuser colour temp, 6500K ,PF 0.9 complete all as specified and directed by Engg-in- Charge.
200
-
-
Supply only in replacement of Recess mounting 36 watt LED of size 2x2 feet slim ceiling light with extruded aluminium housing powder coated, milky diffuser, operating voltage 120V-280V, power factor0.95, inbuilt Short circuit protection and surge protection, soft and uniform light distribution, system lumen more than 100lm/W,CRI80, integrated constant current electronic driver with 2 year warranty all as specified and directed.
200
-
-
Supply only in replacement indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 5watt LED Tube fitting suitable for mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K,100Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified.
20
-
-
Supply only in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 7 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and as directed.
20
-
-
Supply only in replacement self adhesive PVC insulation tape, 1.8 cm x 6.5 mtr, good quality complete all as specified.
300
-
-
Taking down old unserviceable existing DB / enclousers any size and type / any descriptions as iron sheet scrap including MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed.
31
-
-
Supply only in replacement MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.
8
-
-
Suply only MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified. Make Havells/Legrand/ABB / C&S.
8
-
-
Supply only in replacement MCB SP 6 - 32 Amps, ' B' series ,bracking cap10KA complete all as specified.
40
-
-
Supply only in replacement SPN 63 Amps,' C' series , bracking cap10KA, 240V complete all as specified.
10
-
-
Supply only in replacement SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts complete with all connection as directed.
15
-
-
Material only for submain wiring alongwith earth wire with 2 x 4.0 Sqmm + 1 x 4.0 Sqmm FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.
Note : Two runs of 4.0 Sqmm(P&N), one run of 4.0 (earth) Sqmm copper cable and one run of PVC Casing and Caping shall be measured as one unit length.
60
-
-
Supply only in replacement of PVC insulated copper wire FRLS of size 1.5 Sqmm (nominal area), single core for repair of no light complaint as required at site.
200
-
-
Supply only in replacement of PVC insulated copper wire FRLS of size 2.5 Sqmm (nominal area) single core for repair of no light complaint as required at site complete all as specified and as dirceted.
600
-
-
Supply only in replacement of PVC insulated copper wire FRLS of size 4.0 Sqmm (nominal area), single core for repair of no light complaint as required at site complete all as specified and as directed.
200
-
-
Supply only in replacement of PVC insulated copper wire FRLS of size 6 Sqmm (nominal area) single core for repair of no light complaint as required at site complete all as specified and as directed.
300
-
-
Supply only in replacement of PVC insulated copper wire FRLS of size 10 Sqmm (nominal area) single core for repair of no light complaint as required at site complete all as specified and as dircetd.
80
-
-
Supply only in replacement 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way complete all as specified.
15
-
-
Supply & replacement of 3 mm thick laminated mica sheet top cover suitable for switch board 8 way to 12way complete all as specified.
15
-
-
Supply only in replacement of non - return valve 15 mm dia horizontal / verticle type ISI Marked,for any cap geysers complete all as specified and as directed.
10
-
-
Supply only in replacement modular metal flush box ,1 / 2 module.
20
-
-
Supply only in replacement modular metal flush box, 3 module.
25
-
-
Supply only in replacement modular metal flush box, 4 module.
40
-
-
Supply only in replacement modular metal flush box, 6 module.
10
-
-
Supply only in replacement modular metal flush box, 8 module.
30
-
-
Supply only in replacement modular white cover plate with frame, 1/2module.
10
-
-
Supply only in replacement modular white cover plate with frame, 3 module.
25
-
-
Supply only in replacement modular white cover plate with frame, 4 module.
20
-
-
Supply only in replacement modular white cover plate with frame, 6 module.
10
-
-
Supply only in replacement modular white cover plate with frame, 8 module.
30
-
-
Supply only in replacement the following items suitable for electric geyser of capacity 25/50 Liters :-
-
-
-
Heating element 1.5 / 2 KW ISI marked including rubber Gasket as per existing type.
50
-
-
Thermostat suitable for 25 Ltrs Geyser (as per the existing type).
50
-
-
Supply only Hot water / cold water pipe 600mm long as per existing type.
10
-
-
Supply only in replacement in replacement of safety valve ISI Marked for any cap geysers complete all as specified and as directed.
10
-
-
Supply only in replacement in replacement of indicator lamp any size / type 230 Volts.for geyser complete all as specified ISI marked.
10
-
-
M&L for submain wiring alongwith earth wire with 2 x 2.5 Sqmm + 1 x 2.5 Sqmm FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.
Note: Two runs of 2.5 Sqmm(P&N), one run of 2.5 Sqmm (earth) copper cable and one run of PVC Casing and Caping shall be measured as one unit length.
200
-
-
Provision of services for maintenance of internal electricity comprising of internal electric wiring, switches, sockets, ceiling rose, regulators, electrical fittings & fixtures,MCB's geyser accesories like heating element, thermostat, taking down and refixing of all type of fans and all other electric work related to buildings all as specified and directed.
Notes:-
(a) All electric points, fixtures & fittings and all other connected electric components should be checked and defective parts to be rectified/replaced/made serviceable.
(b) Defective spares will be measured and paid separately.
(c) The contractor should employ two skilled electricians and two helpers for carrying out day to day maintenance in General Shift from 0900 hrs to 1700 hrs for technical and domestic area of 3 BRD.
(d) T&P items and testing lamp shall be provided by the Contractor at his own cost.
(e) Any spare required for rectification/replacement will be paid under relevent item. (f) The Contractor or his authorized representative (with mobile phone) shall remain in the complaints cell for collection of complaint slip from JE E/M. (g) All complaints slip shall be returned by the contractor in the complaints cells of GE (AF) MC Chd located in Technical/domestic area on same day to the JE E/M or his representive after necessary repair/replacement have been carried out and signature of the user on the complaint slip.
(h) It is responsibility of the contractor for rectification of complaint to the entire satisfaction of the user.
11
-
-
Note:- Amount of credit of Rs. 70685.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner