Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date2 Sep 2024
Closing Date28 Sep 2024
Tender Amount₹ 21,00,000
Costs
EMD
₹ 42,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669714_1Bid Award Id
ViewTender No
GE/CHD-38/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Schedule A Notes, Schedule of Credit, Schedule B C D ,Special conditions, Particular specification and other connected documents.
BOQ Items
M&L for earth work in excavation in any type of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m depth, as directed by Engineer-in-charge
67
-
-
M&L for earth work in excavation in ordinary rock by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift from 1.5m to 3.0m depth, as directed by Engineer-in-charge
35
-
-
M&L for earth work excavation in Ordinary rock by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift from 3.0m to 4.5m depth, as directed by Engineer-in-charge
1
-
-
M&L for earth work in excavation in soft/disintegrated rock over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m depth, as directed by Engineer-in-charge
47.2
-
-
Returning and filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick using soft/disintegrated rock complete all specified and as directed.
94.94
-
-
Removal of excavated soil to a distance exc 250 metre and n.exc 500m depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified.
130.28
-
-
M&L RCC Nominal Mix Type B1 (1:2:4) using 20mm graded aggregates in Foundations, including rafts, footings, foundation
beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
1.42
-
-
M&L RCC Nominal Mix Type B1 (1:2:4) using 20mm graded aggregates in Columns, pillars, piers, posts and struts complete all specified and as directed.
1.94
-
-
M&L RCC Nominal Mix Type B1 (1:2:4) using 20mm graded aggregates in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all specified and as directed.
1.89
-
-
M&L RCC (nominal mix) Type B1 1:2:4 (20 mm graded
aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
1.34
-
-
M&L RCC Nominal Mix Type B1 (1:2:4) using 20mm graded aggregates in Chajjas complete all as specified.
0.13
-
-
Formwork for fair finished surface to flat faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter with fair finished surfaces.
37.8
-
-
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, including attached pilaster and buttresses etc., complete all as specified and as directed.
15.64
-
-
Formwork to sides of pillars, posts, struts, piers, columns and stanchions with fair finished surfaces complete all as specified.
14.4
-
-
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping complete all as specified and as directed.
14.85
-
-
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.with fair finished surfaces complete all specified and as directed.
2.93
-
-
M&L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work complete all as specified and directed.
13
-
-
M&L for plain cement concrete (1:2:4), type B-2, using 40 mm graded crushed stone aggregate as in foundations, filling , mass concrete, complete, all as specified and directed.
3.74
-
-
Brickwork with old Size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1 :4 with all as specified and directed.
5.69
-
-
S&F 0.50mm thick pre painted galvalume aluminium zinc coating GI based corrugated steel sheeting having 550 Mpa as in roof covering/cladding to walls fixed with self tapping screws as specified
45
-
-
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
211.99
-
-
S&F MS Fe-410- W(Gde- E-250) quality-B Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment as in covering the duct complete all as specified and as directed.
93
-
-
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc(Fe 410-W (GdeE- 250) qualityA) complete all as specified and as directed.
472.33
-
-
M&L for 20 mm thick granite machine cut stone slab (table rubbed polished) as in cooking platform,jamb,cill setted and jointed with cement slurry and bedded over & including 15mm thick bedding layer of cement sand mortar (1:4), & pointed with white/ coloured cement including grinding, rounded and chamfered edges and granite polishing etc complete all as specified and as directed.
0.85
-
-
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar1:6, complete all as specified and as directed by Engr-in-Charge.
15
-
-
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces, in cement mortar1:4, , complete all as specified and as directed by Engr-in-Charge.
23.03
-
-
M&L for Two coats of cement base paint on new wall surfaces including all necessary preperation of new wall surfaces wetting and curing and priming, complete all as specified.
33.03
-
-
M&L for two coats of distemper oil emulsion (OBD) on new plastered wall surfaces of any description over and including 2mm thick wall care putty complete all as specified including preperation of surfaces
15
-
-
M&L Earth filling under floors or in foundations incl spreading, levelling, watering, and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
0.74
-
-
M&L 75 mm thick Cement concrete type D2,1:4:8 (40mm graded stone aggregate) as in sub base,path,floor, hardstanding complete as as specified and directed.
415
-
-
M&L 75mm thick Plain cement concrete (1:4:8), type D-2, using 40 mm graded stone aggregate as foundations,
filling and mass concrete, complete all as specified and directed.
2.07
-
-
M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed of mortar 15 mm thick in CM (1:6) complete all as specified and as directed.
5
-
-
M&L Glazed ceramic coloured,,tiles 450x300x7mm thick in vertical surfaces such as skirting,dados and risers to steps over and including 10mm thick plaster in CM (1:4) complete all as specified and as directed.
4
-
-
M&L TMT bars 10mm dia and over cut to length , bent to shape required including , cranking hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
413.99
-
-
M&L TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and as directed by Engr-in-Charge.
520
-
-
Material & labour for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
53.88
-
-
M&L for Hard core with broken stone or boulders of gauge not exceeding 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed/rolled to a true surface complete all as specified.
49.2
-
-
Hardcore (Broken Bricks) of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified.
2.1
-
-
M&L for plain cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate as in Plinth protection, 75mm thick finished even and fair complete including necessary form work all as specified .
10
-
-
Forming contraction (dummy) joints 25 mm deep x 10mm wide, filled with sealing compound Grade A, complete all as specified and as directed.
4
-
-
S&F factory made box type steel windows steel frames 80mmx60mm(peripheral) and 80mm x75mm(internal members)made out of cold rolled 1.25mm thick sheet having steel window/ventilator shutter of MS tabular section of size 50mmx20mmx1.1mm thick fixed with box type hollow tabular section beading of glazed and wire shutter handle of 100mm size made out of Z-section 02 Nos M stove enameled black tower bolt of size 120mmx 2 Nos, 150mm mild steel hooks and eyes including a shop coat of primer fixed in repairs all as specified and directed by Engr-in-Charge.
2.4
-
-
All as per item no 44 above item but without glazing bar
2.4
-
-
S&F 4mm sheet glass ordinary quality and glazing with oil putty in squares exc 0.5 sqm in each pane complete all as specified and directed.
1.8
-
-
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and and average width of aperture not more than 1.40mm fixed with stainless steel wire staples.
1.8
-
-
M&L for plain cement concrete (1:2:4) Type -B2 using 40 mm graded crushed stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts, (including caps and bases) , complete all as specified and directed
16.2
-
-
M&L for excavating in post holes (or similar holes) in hard/dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
4
-
-
M&L Cement concrete type B -0, 1:2:4 (12.5 mm graded stone aggregate) 40 mm thick, as in leveling concrete in floor finished even & rough to receive top floor layer/finish complete all as specified & directed.
30
-
-
Material & labour for 80mm thick non skid pre polished coloured interlocking paver block made with electro vibro technology with rubber/ PVC moulded of not less than compresive strength 30 Kg/Cm and shape and size confirming to IS 15658-2006 of M-40 Grade with grey cement and pigment, complete all as specified and directed by Engineer in Charge.
385
-
-
M&L for sand filling under floors or in foundations including watering and consolidation,complete all as specified and directed by Engineer in Charge.
11.55
-
-
M&L for Stone kerb of roughly squared stones lime or sand stone of size 15cm x 30cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar1:6 and struck flush , complete, all as specified and directed.
100
-
-
Material & labour for providing cement concrete Type B1 1:2:4 (20mm graded crushed stone aggregate) kerbs or mut stops, rounded or chamfered on edges etc complete including necessary form work complete all as specified and directed.
8
-
-
Supply and fix mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed.
402
-
-
M&L for cement concrete in surface channels and drains in cement concrete 1:3:6 type C2 (40 mm graded stone aggregate) complete all as specified and directed.
4
-
-
Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
8
-
-
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:4) with old size bricks disignation 7.5 complete all as specified and directed.
23
-
-
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement mortar1:4, complete all as specified and as directed by Engr-in-Charge.
48
-
-
M&L providing for PCC 1:3:6 Type C-1 using 20mm graded crushed stone aggregate as in bed plates,complete all as specified and directed.
0.2
-
-
S& F 150mm SGSW pipe, laid in trenches and jointed,complete all as specified and as directed by Engr-in-Charge.
55
-
-
M&L for Concrete bed (1:4:8 type D-2) to 150mm SGSW pipe, (grade ‘A’) including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed by Engr-in-Charge.
50
-
-
S&F 100 MM dia Cast iron soil, wast and vent pipe in any length with or without ears, with cement joints, fixed in floors , complete all as specified and directed.
4
-
-
S&F Cast iron 100mm bore cowls, complete all as specified and directed.(Sand cast pipes), complete all as specified and directed.
2
-
-
Supplying and filling brick bats (broken brick coarse
aggregate ) of size not less than 63mm, complete all as specified and as directed.
3
-
-
M & L Honey combing brick work of thickness 345mm with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:4) with old size bricks designation 7.5 complete all as specified and directed.
3
-
-
M&L for point wiring using approved colour coding as per IS ( for Phase and neutral) with copper conductor 1.5 sqmm ( Cross sectional area) single core multistranded FRLS ,PVC insulated and unsheathed cable 1100 volts grade,conforming to IS drawn and including PVC concealed coduit with fittings ISI marked ,terminated in modular switch boxes incl 1.5 sqmm (cross sectional area ) single core ,multistranded ,FRLS PVC insulated and sheathed cable as earth continuity conductor connected to earth dolly for one light/fan point control by one way switch complete all as specified and directed. 1. Modular switch sockets fan regulators shall be measured and paid separately.
3
-
-
All as per item No. 67 above but for one 3 pin 5 amp socket on indipendant board complete all as specified and directed.
1
-
-
All as per item No. 67 above but with 4 sqmm copper conductor for 15 amp socket with 2.5 sqmm earth continuity conductor
1
-
-
S&F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal complete all as specified and directed.
1
-
-
S&F of socket outlet 3-pin,6A flush type of suitable size complete all as specified and directed.
1
-
-
S&F of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
1
-
-
S & F stepped type electronic fanregulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
1
-
-
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
1
-
-
S&F of Switch piano type single pole one way 6 Amp complete all as specified and directed.
3
-
-
S&F of isolator SP, 6-40 Amps, 230 Volts complete all as specified and directed.
3
-
-
Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 2 way , 240 volts without bus bar, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections complete all as directed.
1
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section in service connections 2 core Stranded conductor complete all as specified and directed.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements