Military Engineer Services Tender

View complete overview of Chandigarh MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 May 2024
Closing Date12 Jun 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Schedule A Notes, Schedule of Credit, Schedule B C D ,Special conditions, Particular specification and other connected documents.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L rewinding to ceiling fan motor of 1400/1500mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves& paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conductor cable of size 23/.0076 upto connector block ( winding wire exc 350 gm and n-exc 750gm ) Complete all as specified and as directed by Engineer-in-charge. Note for item No 3 & 4 :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account

180

-

-

... More
Supply only Ball bearing suitable for celing fans of any sweep.

750

-

-

... More
Supply only gun metal bush suitable for celing fans of any sweep.

250

-

-

... More
Supply only Mild steel shaft suitable for celing fans of any sweep.

250

-

-

... More
Rewinding to exhaust / pedestal/ wall mounting fan motor of 225 to 380mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cable of copper conductor of size 23/.0076 up-to connector block Complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
All as per above item No 08 here-in –before but 450 mm sweep Note for item No 8 & 9 :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account (ii) Spare parts like as Ball bearings, Bush & shaft shall be measured & paid as Supply only separately under respective item No 10 to 12 of this schedule . Fixing charges of these spare parts shall be deemed to be included in the unit rate of this item without entertaining extra cost on this account.

20

-

-

... More
Supply only ball bearing suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan

100

-

-

... More
Supply only gun metal bush suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan

50

-

-

... More
Supply only mild steel shaft suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan

50

-

-

... More
M&L circuit kit plate including diode, IC, transistor, rectifier and invertor as per existing make and model for BLDC remote/non-remote ceiling fan 1200/1400 mm sweep Complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
M&L lathe work for taking out bush from the lower body part of ceiling fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft Complete all as specified and as directed by Engineer-in-charge.

60

-

-

... More
M&L replacement to unserviceable capacitor 4 mfd in lieu of provided with new capacitor dry type 4 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge. Make :- DENFOS/ INDOFOS /EPCOS /HAVELLS

200

-

-

... More
M&L replacement to unserviceable capacitor 2.5/3.15 mfd in lieu of provided with new capacitor oil type 2.5/3.15 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge. Make :- DENFOS/ INDOFOS /EPCOS/HAVELLS

1000

-

-

... More
Preparation surfaces, cleaning thoroughly with kerosene oil ceiling fans 1200mm/1400mm/1500mm sweep to remove only dust and any type of spots and painted with synthetic enamel paint (white colour) with help of spray gun machine, including writing MES No, complete all as specified and as directed by Engineer-in-charge.

200

-

-

... More
M&L for replacement to unserviceable fan blades (set of three blades) suitable for 1200/1400/1500mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
M&L for replacement to unserviceable rusted MS rod up to 3 feet including clamp, nut, bolt, washer & split pin suitable for any sweep ceiling fan Complete all as specified and as directed by Engineer-in-charge.

100

-

-

... More
M&L for replacement to unserviceable rubber reels with new suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.

1300

-

-

... More
M&L for replacement to unserviceable PVC canopy suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.

450

-

-

... More
Shifting only Exhaust fan any sweep,suitable for AC single phase, 240 volts, 50 Hz, connecting up including provision of PVC insulated, unsheathed copper conductor flexible cable 3core, 23/0.0076 and fixed on wall by using 4 Nos, 100 mm long, 12 mm dia bolts, nuts and washers and grouted in wall in cm(1:3) including making opening in wall of suitable) size for exhaust fan & making good to disturbed surface of wall with PCC(1:2:4) Type –B-1 or Cement mortar CM(1:3) complete all as specified and as directed by Engineer-in-Charge.

25

-

-

... More
Taking down desert cooler of any make & size fixed at different site / location and repair to desert cooler to stop any type of leakage, tightening / replacing rusted screw nuts, bolts & washers with new of same size etc including floor cleaning, scraping all scales from internal & external surfaces and painted to desert cooler with two coats of synthetic enamel paint on external surface & black Japan paint on internal surfaces with help of spray gun machine including writing of MES/ SM No in 5cm height and re-fixing the desert cooler after necessary oiling and greasing of fan and water lifting pump at site/location complete all as specified and as directed by Engineer-in -Charge. NOTE : Spare parts shall be measured & paid seperatly under respective item of this schedule .

135

-

-

... More
Replacement of fan motor of 1/6 HP 50Hz’s suitable 230volt AC Make: Khaitan/CG/Bajaj

75

-

-

... More
Replacement of submersiable Tulu pump / water fitting pump.Make: Khaitan/CG/Bajaj

100

-

-

... More
Replacement of Wooden pads ( set of three )

100

-

-

... More
Replacement of 15mm bore High density polythene pipe

100

-

-

... More
Replacement of PVC Water distributor 3-way

100

-

-

... More
Replacement of Selector switch ( three speed )

100

-

-

... More
Replacement of PVC Bend right angle

50

-

-

... More
Replacement of 3-Pin plug top, 5 Amp, 230volt AC

100

-

-

... More
Replacement of Flexible cable copper conductor sizes 23/.0076, 3-core PVC Insulated sheathed

200

-

-

... More
Replacement of 15mm bore Ball valve with float ball PTMT

100

-

-

... More
Replacement of 15mm bore, 450mm to 600mm long PVC Connection pipe with PVC Union nut.

100

-

-

... More
Replacement of 15mm bore stop cock PTMT Make for item No 33 to 35:-- PARYAG /Pearl /SHAKTI

100

-

-

... More
M& L for Replacement of existing unserviceable MS steel stands of desert coolers at different locations with cooler stand made out MS angle iron 35mm x 35mm x 3mm thick embedded in wall with PCC (1:2:4) type B-1 block including applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.

25

-

-

... More
Taking down window type Air conditioner capacity 1.5 to 2.0 Ton strip opening, general cleaning of filter, washing complete unit with detergent and chemical including re-fixing in the same opening or shifted to other opening /room complete all as specified and as directed by Engineer-in-Charge.

25

-

-

... More
All as per above item No 37 here-in-before but split type Air Conditioner 1.5 to 2.0 Ton.

21

-

-

... More
All as per above item No 37 here-in-before but cassette type Air Conditioner 2.0 Ton.

7

-

-

... More
Taking out PCB unit from AC’s split / window / cassette type carry to workshop for repair and refixing PCB unit after repair to existing AC complete all as specified and as directed by Engineer-in-Charge.

25

-

-

... More
S&F PCB/Mother Board Unit alongwith Remote Control Unit suitable for 1.5/2/3 Ton window/ Split/ cassette/ package Type Air Conditioning(including inverter type) complete all as directed.

3

-

-

... More
Disconnection and removing the unserviceable Display Unit and S&F Digital Display for indicating Temperature, Temperature Sensor for 1.5/2/3 Ton window/ Split/ cassette/ package Type Air Conditioning(including inverter type) complete all as directed. Make :- LG/Hitachi/Voltas

2

-

-

... More
Disconnection and removing the Old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 1/2" dia or 1/4" dia connecting alongwith Insulation Sleeves to the existing position incl leak testing complete all as directed by Engineer in charge.

25

-

-

... More
Replacement of unserviceable sealed compressor of 1.5 Ton capacity window type AC with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning & testing for leakage etc complete all as specified and directed by Engineer-in-charge Make :SRI-RAM/ TEKAM SHAH/ KIRLOSKER / WHIRLPHOOL/VOLTAS

17

-

-

... More
All as per above item No 44 here-in-before but 2.0 Ton capacity window type AC.

5

-

-

... More
All as per above item No 44 here-in-before but 1.5 Ton capacity split type AC (including inverter type).

12

-

-

... More
All as per above item No 44 here-in-before but 2.0 Ton capacity split type AC (including inverter type).

2

-

-

... More
All as per above item No 44 here-in-before but 2.0/3.0 Ton capacity cassette/package type AC. Note for item No 44 to 48:--- (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured & paid separately under respective item of BOQ.

4

-

-

... More
S&F for replacement of unserviceable condenser unit with new of existing make and model suitable for split type AC 1.5 Ton capacity, complete all as specified and as directed by Engineer-in-Charge Make-Voltas/whirlpool/LG/Kirlosker

10

-

-

... More
All as per above item No 49 here-in-before but 2.0 Ton capacity split type AC (including inverter type). Make-Voltas,whirlpool,LG,Kirlosker

2

-

-

... More
All as per above item No 49 here-in-before but 2.0/3.0 Ton capacity cassette /package type AC Make-Voltas/whirlpool/LG/Kirlosker

2

-

-

... More
S&F for replacement unserviceable cooling coil unit with new of existing make and model suitable for window/split type AC 1.5 Ton capacity, complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
All as per above item No 52 here-in-before but 2.0 Ton capacity split type AC (including inverter type).

2

-

-

... More
All as per above item No 52 here-in-before but 2.0/3.0 Ton capacity cassette /package type type AC

2

-

-

... More
Recharging of gas R-22/134 in air conditioner unit window type/ split type/ cassette type 1.5 /2.0 ton complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S&F replacement of unserviceable thermostat switch with new of existing make and model suitable for window type/ split type/ cassette/package type AC 1.5/2/3.0 Ton capacity, complete all as specified and as directed by Engineer-in-Charge. Make :- RENUTROL/INDFOS/BAJAJ

25

-

-

... More
S&F replacement of unserviceable starting capacitor 100 -120 mfd with new suitable for window type/ split type/ cassette/package type AC 1.5/2 Ton capacity & water cooler of any capacity, complete all as specified and as directed by Engineer-in-Charge. Make : USHA / SIEMEN/EPCOS

40

-

-

... More
S&F replacement of unserviceable running capacitor 36mfd with new suitable for window type/ split type/ cassette/package type AC 1.5/2 Ton capacity & water cooler of any capacity complete all as specified and as directed by Engineer-in-Charge . Make : USHA / SIEMEN/BAJAJ

45

-

-

... More
S&F replacement of unserviceable front grill with new as per existing suitable for window type/ split type AC 1.5/2.ton capacity complete all as specified and as directed by Engineer-in-Charge.

20

-

-

... More
S&F replacement of unserviceable blower motor with new blower motor suitable for window type AC of 1.5/2 Ton capacity as per exising capacity motor complete all as specified and as directed by Engineer-in-Charge. Make : USHA/AUE/BAJAJ

20

-

-

... More
S&F replacement of unserviceable blower motor with new blower motor suitable for split type AC of 1.5/2 Ton capacity as per exising capacity motor complete all as specified and as directed by Engineer-in-Charge. Make : USHA / AUE/BAJAJ

15

-

-

... More
S&F replacement of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 70/0.0076 for AC of any capacity complete all as specified and as directed by Engineer-in-Charge .

150

-

-

... More
S&F replacement of unserviceable knob with new knob suitable for window type / split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.

15

-

-

... More
S&F replacement of unserviceable selector switch with new selector switch (ON/OFF five steps) suitable for window type / split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.

40

-

-

... More
S&F replacement of unserviceable air filter with new air filter suitable for window type / split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.

40

-

-

... More
S&F replacement of unserviceable over load protector with new over load protector suitable for split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.

40

-

-

... More
Carried out of Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler complete. Note :- The leakage to be observed for 24 Hours and after confirmation only the refrigerant is to be provided to the unit.

15

-

-

... More
Disconnection and removing the old u/s Outdoor Stand and S&F New Outdoor Stand made of Iron bracket to accomodate the air conditioner along with fixing materials complete

3

-

-

... More
Uninstalling 1.5/2.0 Ton window/Split Air Conditioner from one place and installing to another place including cutting and making opening in wall or cutting to steel window / glass pane make a opening for fixing of AC’s of any capacity and cover unused space with 4 mm thick PVC sheet fixed to wooden / steel frame with mild steel screw/nails complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Taking down carefully dismantling voltage stabilizer of capacity 03 KVA to 5 KVA, single phase 240 volt AC of any make and any size opening up for inspection necessary repair and replacement of worn out/defective spare parts, rewinding of main transformer with supper enameted copper wire of existing gauge and weight reassembling, connecting up, testing etc complete all as directed by Engineer-in-Charge (Necessary spare parts required for replacement shall be measured and paid for separately as supply only) and fixing is included under this item. Make of winding wire : Devi Dayal/Atlas/BPL

5

-

-

... More
S&F relay condenser and electronic circuit suitable for voltage stabilizer of capacity 3 KVA to 5 KVA of existing make and size complete all as specified and as directed by Engineer-in-charge.

3

-

-

... More
Disconnecting, opening and taking out unserviceable sealed compressor of water cooler of capacity 150/180 litres and replaced with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leakage etc complete all as specified and as directed by Engineer-in-charge. Make : SRI-RAM/ TAKAM SHAH/ KIRLOSKER .

10

-

-

... More
All as per above item No 72 hereinbefore but water cooler of capacity 40/80 litres. Note for item No 72 & 73: (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured &paid separately under respective item of BOQ.

8

-

-

... More
Cleaning the system with CTC and charging the refrigerant gas R-22/134 including replacing strainer and rectification of leakage of the system from water cooler of150 litres capacity complete all as specified and as directed by Engineer-in-charge.

25

-

-

... More
All as per above item No 74 here-in-before but water cooler of capacity 40/80 litres

8

-

-

... More
S&F for internal wiring for water coolers 150/80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.

15

-

-

... More
S&F replacement of unserviceable starting relay assembly with new starting relay assembly suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge

15

-

-

... More
All as per above item No 77 here-in-before but water cooler of capacity 40/80 litre

4

-

-

... More
S&F replacement of unserviceable over load protector with new over load protector suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
All as per above item No 79 hereinbefore but water cooler of capacity 40/80 litre

5

-

-

... More
S&F replacement of unserviceable fan motor with new fan motor suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
All as per above item No 81 hereinbefore but water cooler of capacity 40/80 liter

8

-

-

... More
M&L 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler as in repair Complete all as specified and as directed by Engineer-in-Charge.

40

-

-

... More
M&L cleaning to water coolers upto 150 ltrs capacity internal & external surfaces of suitable repairs to body & stop leakage etc, replacing unserviceable nut bolts & washers etc including preparation of external surfaces and bottom body and painted with anticorrosive synthetic enamel paint with help of spray gun machine and writing SM / MES No in 5cm height Complete all as specified and as directed by Engineer-in-Charge.

30

-

-

... More
All as per above item No 84 here-in-before but water cooler of capacity 40/80 liter

8

-

-

... More
S&F replacement of unserviceable thermo-state switch with new thermo-state switch suitable for water cooler any capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
Disconnecting & opening of deep freezers and taking out unserviceable sealed compressor of capacity 300/320 liters and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leaking etc complete all as specified and as directed by Engineer-in-charge. Make :-- SRI-RAM/ TAKAM SHAH/ KIRLOSKER. Note for item No 87 & 88: (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. ( ii) Recharging with refrigerant gas shall be measured & paid separately under respective item of BOQ.

11

-

-

... More
All as per above item No 87 here-in-before but 205 Litre

1

-

-

... More
Cleaning the system with CTC and charging the refrigerant gas R-134/22 including replacing strainer and rectification of leakage of the system from deep freezer upto 320 litres capacity complete all as specified and as directed by Engineer-in-charge.

5

-

-

... More
M&L for internal wiring for deep freezer upto 320 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.

5

-

-

... More
S&F replacement of unserviceable starting relay assembly with new starting relay assembly suitable for deep freezer water cooler of 320 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge

5

-

-

... More
S&F replacement of unserviceable over load protector with new over load protector suitable for deep freezer 320 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
S&F replacement of unserviceable fan motor with new fan motor suitable for deep freezer upto 320 liter capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
Disconnecting & opening refrigerator of capacity 210/320 litre and taking out unserviceable sealed compressor and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & the leakage etc complete all as specified and as directed by Engineer-in-charge. Make :SRI-RAM/ TIKAMSHAH/ KIRLOSKER / WHIRLPOOL .

18

-

-

... More
All as per above item No 94 here-in-before but 180 litres

5

-

-

... More
Recharging of gas F-12 in refrigerant cap 180/210/320 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.

25

-

-

... More
Replacement of freezer door plastic with tension spring as per existing model suitable 160/200 liter cap.

10

-

-

... More
Replacement of Fruit /vegetable tray of any capacity as per existing make & model

20

-

-

... More
Replacement of Pigmy lamp (bulb)

20

-

-

... More
Replacement of Door liner ( Plastic ) for upto 310 liter capacity

8

-

-

... More
Replacement of Door magnetic gaskest for upto 310 litre cap.

8

-

-

... More
Replacement of Relay box type for any cap.

8

-

-

... More
Replacement of over load protector for any Cap.

10

-

-

... More
Replacement of refrigerator freezer of capacity 180 to 320 ltr Complete all as specified and as directed by Engr-in-Charge. .

4

-

-

... More
Scraping paint completely, preparing internal and external steel surfaces and applying synthetic enamel paint over a coat of red oxide primer with spray gun after filing the cavities with filler of capacity 320 litre refrigeator complete all as specified and as directed by Engr-n-Charge.

5

-

-

... More
Disconnecting & taking down unserviceable geyser of 25/50 litre capacity of any make from the wall and opening carefully including descaling the inner surface by scrapping, carrying out soldering/ brazing/gas welding to prevent the leakage, filling of glass wool & replacement of any other defective spares , including replacement of required number of stainless steel screws, nuts & bolts,assembling the the same after repair work and fixing in its orginal place, connecting to water mains and electric supply, testing after repairs, complete all as specified and as directed by Engineer-in-charge. Note :spare parts and glass wool shall be measured and paid separtaly under respective items of BOQ.

350

-

-

... More
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.

100

-

-

... More
All as per above item No 107 here-in-before but 50 litre capacity.

10

-

-

... More
S&F replacement of unserviceable Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembling & fixed at site complete all as specified and as directed by Engineer-in-Charge.

30

-

-

... More
All as per above item No 109 here-in-before but 50 ltr capacity.

10

-

-

... More
Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 2000 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc complete and all as specified.

250

-

-

... More
Replacement of unserviceable Geyser thermostat switch any type/size with new thermostat switch ISI marked of range 0-100 degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc complete and all as specified

150

-

-

... More
Supply and fix in repairs 06/08 hole Assembly for water heateer ISI Marked complate all as specified and as directed. MAKE:-Crampton/Havells/ Venus.

50

-

-

... More
Replacement of unserviceable Safety valve

70

-

-

... More
Replacement of unserviceable indicator lamp assy with new indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting complete and all as specified

100

-

-

... More
Replacement of unserviceable 23 to 30 cm long ,10 mm bore C.P Connection with brass union

100

-

-

... More
Replacement of unserviceable Gun metal non return valve ,15 mm bore

50

-

-

... More
S&F in repair PVC connection 450mm long for cold / hot water heavy duty PK Aqua made out of double layer at Nylon & wire fabric at pressure 6Kg / CM both side, CP brass 15mm bore coupling or nuts complete and all as specified.

60

-

-

... More
Replacement of unserviceable Apparatus plate for Syphon Assy for 25 litre

70

-

-

... More
Replacement of unserviceable Apparatus plate for Syphon Assy 50 litre

4

-

-

... More
Replacement of bottom/top plates made out of MS sheet of 1mm thick made to shape of required size factory made complete fitted with machining screws duly painted with synthetic enamelled white paint complete and all as specified.

50

-

-

... More
S&F sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP,20Amp(C-series) as in repair complete all as specified and as directed by Engineer-in-Charge.

70

-

-

... More
Replacement of Rubber O ring /gaskit for 25 ltrs

100

-

-

... More
M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.

100

-

-

... More
M&L for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
Cutting chasing in brick walls for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge

200

-

-

... More
S&F in repair for 15mm bore long shank stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S&F in repair for 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S&F in repair for 20mm bore stop valve cast copper alloy chromium plated fancy type, long shank cup concealed high pressure with cutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S&F for 15mm bore steel water tubing medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors including taking out unserviceable pipe complete all as specified and directed by Engineer-in-charge.

100

-

-

... More
All as per above item No 130 here-in-before but 20mm bore

50

-

-

... More
S&F replacement of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 40/0.0076 for AC of any capacity complete all as specified and as directed by Engineer-in-Charge .

300

-

-

... More
Taking down carefully u/s point wiring and M&L for Point wiring complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc, including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc all as specified and as directed for One 3 pin socket outlet 5 Amps on independent board .(for Desert Coolers)

50

-

-

... More
All as per Item No 133 here in above but for One ceiling fan/ exhaust fan point controlled by one, one way 5 Amps switch

200

-

-

... More
Taking down carefully u/s point wiring and M&L for Point wiring complete with 4 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc all as specified and as directed for One 3 pin socket outlet 5 Amps on independent board. (for geyser & AC Point)

50

-

-

... More
Taking down carefully u/s point wiring and M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and modular type metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc all as specified and as directed for one switch socket outlet 15 Amps on independent board complete all as specified and as directed by Engineer-in-charge.(Water coolers and Refrigerators)

50

-

-

... More
Supply and Fixing switch socket combination flush type universal 2 in 1, 3 pin 5 Amps

50

-

-

... More
Supply and Fixing switch socket combination flush type universal 2 in 1, 3 pin 15 Amps

50

-

-

... More
Supply and fix MCB SPN 230 volts 32 Amps with 10KA breaking capacity.

17

-

-

... More
Supply and fix MCB SP 230 volts 16/20 Amps with 10KA breaking capacity.

25

-

-

... More
Supply and fix MCB DB SPN 4 way double door with 200 amps rated bus bar complete all as spfd and directed.

10

-

-

... More
Disconnection and removing the u/s 3X1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and M&L for 3X1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor drawn in the existing metal/ PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete. Note : Three runs of cable measured as one unit.

100

-

-

... More
All as per Item No 142 here in above but of 3X2.5 Sqmm.

120

-

-

... More
All as per Item No 142 here in above but of 3X4 Sqmm.

80

-

-

... More
All as per Item No 142 here in above but of 2X6 Sqmm.

75

-

-

... More
Disconnection and removing the u/s regulator and Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type.

500

-

-

... More
Disconnection and removing the u/s ceiling rose and S&F Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body.

25

-

-

... More
Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete.

100

-

-

... More
M&L for 4mm thick PVC sheet of white colour including,cutting & fixing around AC’s / Desert cooler for insulation purposes complete all as specified and as directed by Engineer-in-Charge. Note :-- PVC Sheet shall be measured & paid equal to window opening without deduction of cutting area for grill opening for desert cooler & AC .

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.