Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date9 Sep 2024
Closing Date19 Oct 2024
Tender Amount₹ 1,40,17,000
Costs
EMD
₹ 2,15,200Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673364_1Bid Award Id
ViewTender No
CWE/TKD/CHD/TOKEN-46 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Removing excavated materials to a distance not exceeding 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as specified and directed.
17.5
-
-
Removal of excavated spoil to a distance exc 1.5km but not exc 5 km complete all as specified and directed by the Engineer -In –charge.
583.84
-
-
Demolition of brick work built in cement mortar in any position and in any location complete all as specified and directed by the Engineer -In –charge.
275
-
-
M&L brick work with sub Class ‘B’ Flyash bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 in any location, complete all as specified and directed by the Engineer -In –charge
220
-
-
All as per item No 07 here-in-before above but except bricks complete all as specified and directed by the Engineer -In –charge.
80
-
-
Taking down cement plaster on any surfaces including raking out joints, hacking for key,scrubbibg down with water etc. complete all as specified and directed by Engr-in-Charge.
5885
-
-
M & L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement with WPC @1% complete all as specified and directed by Engr-in-Charge.
8276.3
-
-
Supply only Integrated WPC complete all as soecified and directed.
778.8
-
-
M&L preparation of new plaster surface applying two coats of cement base paint on walls complete all as specified and directed by Engr-in -charge.
8001.3
-
-
Demolition of 150/200 mm bore SGSW/NP2 drain pipes including PCC haunching and bedding jointed in cement mortar and taking out including removal, complete all as specified and directed by the Engineer -In –charge.
3794
-
-
H.D.P.E. Double Wall Corrugated (DWC) Pipes (ISI marked) 150mm bore SN-4 Class as per IS 16098 part II for nonpressure Underground drainage and Sewerage applications with and including cost of special O rubber ring couplers etc. , Laid in trenches on concrete bed to level/ gradient jointing and testing with appropriate class fittings as per manufacturer's instructions including jointing accessories and fittings complete, all as specified and directed by Engineer-in-Charge.
400
-
-
H.D.P.E. Double Wall Corrugated (DWC) Pipes (ISI marked) 200mm bore SN-4 Class as per IS 16098 part II for nonpressure Underground drainage and Sewerage applications with and including cost of special O rubber ring couplers etc. , Laid in trenches on concrete bed to level/ gradient jointing and testing with appropriate class fittings as per manufacturer's instructions including jointing accessories and fittings complete, all as specified and directed by Engineer-in-Charge.
300
-
-
M&L Plain cement concrete type C-2, 1:3:6 ( using 40mm graded stone aggregate) as in concrete bed including packing under & haunching against sides of pipes after the pipe are laid and tested for 150mm complete all as specified and directed by the Engineer -In –charge.
380
-
-
S&F 150mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars, in repair complete all as specified and directed by Engr-in-Charge.
1317
-
-
S&F Plain cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in concrete bed to drain pipes for 150mm bore pipe including forming cradles, (Thickness & width as per SSR) complete all as specified and directed by the Engineer -In –charge.
1251.15
-
-
S&F 200mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars, in repair complete all as specified and directed by Engr-in-Charge .
1777
-
-
S&F Plain cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in concrete bed to drain pipes for 200mm bore pipe including forming cradles, (Thickness & width as per SSR) complete all as specified and directed by the Engineer -In –charge.
1688.15
-
-
M&L Plain cement concrete type C-2, 1:3:6 using 40mm graded stone aggregate as in concrete bed including packing under & haunching against sides of pipes after the pipe are laid and tested for 150mm complete all as specified and directed by the Engineer -In –charge.
285
-
-
Demolition of cement concrete (reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed by the Engineer -In –charge.
22.16
-
-
M & L for Providing, precast (Factory Made) cement concrete (1:2:4) Type B1 (20 mm graded aggregate in landings, cover slabs (for manholes etc.) set in cement mortar 1:6 chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed by the Engineer -In –charge.
18.16
-
-
M & L for Providing, cement concrete (1:2:4) Type B1 (using 20 mm graded aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed by the Engineer -In –charge.
4
-
-
M & L for TMT bar 10mm and cut to length, bent to shape required including cranking bending, spirally for hoping for column hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and as directed by the Engineer -In - Charge.
471
-
-
Cutting into existing manhole for connecting new drain, making good to pipes and rendering cutting out existing benching for and forming branch channel (½ round of ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150/200 mm bore pipe complete all as specified and directed by the Engineer -In –charge.
64
-
-
Demolition of cement concrete (unreinforced) below or above ground level n exc 15 cm thick complete all as specified and directed by the Engineer -In –charge
201.38
-
-
M & L 75 mm thick PCC 1:3:6 type B-2, (using 20 mm graded stone aggregate ) finishing cement concre surface even and smooth with using extra cement complete all as specified and directed by the Engineer -In –charge. Note : PCC shall be laid in alternate bays
885
-
-
M & L 100 mm thick PCC 1:4:8 type D-2, (40 mm graded stone agg ) finishing cement concre surface even and smooth without using extra cement complete all as specified and directed by the Engineer -In –charge
885
-
-
M & L 50mm thick PCC 1:4:8 type B-2, (40 mm graded stone agg ) finishing cement concre surface even and smooth without using extra cement complete all as specified and directed by the Engineer -In –charge
930
-
-
M&L in repairs machine pressed pre polished precast concrete interlocking colour paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-30 grade with grey cement and pigment including old dismantling, complete.
756
-
-
All as per srl item no. 31 here-in-before above but except paver complete all as specified and directed.
189
-
-
M&L 40 mm thick sand screed bed for interlocking tiles including well rammed and consolidation all as per direction by Engr-in- Charge.
37.8
-
-
S&F in repair110mm PVC (SWR) pipes single socket in any length with rubber ring joints, laid in trenches, wall, floors or laid in sunken floors, walls etc. complete all as specified and directed by Engr-in-charge.
1050
-
-
S&F in repair 110 mm PVC bends,branch piece or similar fitting as reqd to make the system functional complete all as specified and directed by Engr-in-charge.
355
-
-
S&F 100 mm cast iron soil waste and vent pipe, sand cast pipes in any length with or without ears jointed with cement mortar (1:3) laid in trenches or in floors or on wall fixed in repair including taking down existing pipes complete all as specified and directed by Engr-in-Charge .
65
-
-
All as per Srl item 36 here-in-before above but 75 mm complete all as specified and directed by Engr-in-Charge.
40
-
-
S&F 100 mm cast iron bends in repairs complete all as specified and directed by Engr-in-Charge
30
-
-
All as per Srl item No 38 here-in-before above but 75 mm complete all as specified and directed by Engr-in-Charge .
30
-
-
S&F Rotational moulded PVC water storage tanks of capacity 500 lts ISI Marked, triple layer (cylindrical vertical with closed top), hoisted and fixed in position with 20mm bore ball valve, including dismantling existing water storage tanks (PVC/RCC) complete all as specified and directed by Engr-in-charge.
45
-
-
Taking up or down steel tubing / KITEK and connections 20mm bore complete all as specified and directed by Engr-in-charge.
3110
-
-
S&F Steel water tubes, medium grade, ISI marked, galvanised, 20mm bore with all fittings, fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engr-in-charge.
3110
-
-
Taking down /out the old unserviceable galvanized iron steel water tubing 25mm bore on the wall/floor or earth including all fittings and fixture complete all as specified and directed.
8750
-
-
Taking down /out the old unserviceable galvanized iron steel water tubing 15/20 mm bore on the wall/floor including all fittings and fixture complete all as specified and directed.
4500
-
-
Supplying ,laying jointing and testing galvanizes iron steel water tubing 25mm bore medium grade laid in trenches, including all fittings and fixtures complete all as specified and directed.
8700
-
-
Supplying ,laying jointing and testing galvanizes iron steel water tubing 20mm bore medium grade laid in trenches, including all fittings and fixtures complete all as specified and directed.
4500
-
-
S&F in repairs of Gun metal gate valve ISI marked CLASS-2 with spindle and iron wheel, both ends screwed, for 20mm bore iron pipe including fittings and fixtures, as required,complete all as specified and as directed.
150
-
-
S&F in repairs of Gun metal gate valve ISI marked CLASS-2 with spindle and iron wheel, both ends screwed, for 25mm bore iron pipe including fittings and fixtures, as required,complete all as specified and as directed.
150
-
-
Cutting existing steel tubing of size 20mm bore for alterations or additions (Each cut measured) complete all as specified and as directed.
150
-
-
Cutting existing steel tubing of size 50mm bore for alterations or additions(Each cut measured) complete all as specified and as directed.
150
-
-
Screwing existing steel tubing of 20mm bore for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and as directed.
150
-
-
Screwing existing steel tubing of 25mm bore for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and as directed.
150
-
-
Taking out old unserviceable water meter and depositing of MES store yard ,supplying fixing and testing of water (cold water flow) 15mm dia,ISI marked Class B, screwed end including coupling and all necessary fittings/accessories, nipples (including cutting existingsteel tubing for alterations or fixing water meter and screwing steel tubingg upto 40mm bore)to make operational,complete all as specified and as directed by Engr-in-Charge. Note:-The water meter shall be tested from water supply department of UT chandigarh before incorporation in the work and OK/Satisfactory report shall be provided with each meter.Testing cost there of shall be deemed in quoted rates.
150
-
-
Supply and fixing MS sheet cover (Not less than 2mm) for water meter fabricated on MS angle iron (25mm X25mm X4mm) with hold fast and locking arrangement including painting with a coat of Red oxide primer complete all as directed by Engineer-in-Charge.
150
-
-
Note :- 1. Excavation and earth work for taking out GI pipe from the trench shall be measured and paid separately. 2. Cutting of road for laying /jointing of pipe line of any size and description shall be measured and paid for in the respective item of schedule including making good the distrubed surface with existing specification. 3. The charge as applicable and payable to U.T. Administrative against cutting of road /drain etc shall be paid by the contractor for each of the block of nomied accomadation within the quoted rate as applicable to the pipe line under respective items.
-
-
-
Schedule of Credit
-