Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date20 Dec 2023
Closing Date19 Jan 2024
Tender Amount₹ 10,00,000
Costs
EMD
₹ 20,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_633690_1Bid Award Id
ViewTender No
GE(AF)/CHD/T-61/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Note for item No. 2.00:- The Johnson Elevator will replace/ repair spares/ components free of cost related to the normal wear and tear such as printed circuit boards and sub components inclusive of belts, roller, bearings, solenoids, coils, break shoes, liners, contactors, contacts, relays, push buttons, indicators, controller chocks, magnets and magnetic switches, door operator motor, door operator, VVVF drive, car door safety drive, limit switch, governor, batteries of UPS, interlocks on hoist way door, main rope, OSG, OSG rope, traveling cable, cable, cabin light, cabin fan, COP accessories, auto rescue device, car top accessories, limit switch etc replacing/ top up of lubricating and other minor electrical/ electronic or mechanical parts as required at the time of inspection cum maintenance and for smooth functioning of Lift all as specified and as directed by the Engineer-in-charge. However, Spare parts listed at SI item No 8.01 to 8.39 here in after shall be measured and paid separately.
-
-
-
Taking out existing door drive and S&F new door drive for 08 passenger lift.
Make- Thyssen Krupp.
1
-
-
Taking out existing track roller and S&F new track roller for 08 passenger lift. Make- Thyssen Krupp.
1
-
-
Taking out existing door lock and S&F new door lock and safety for 8 passenger lift. Make- Thyssen Krupp.
1
-
-
Taking out existing door contact switch and S&F new door contact switch and safety for 8 passenger lift. Make- Thyssen Krupp.
1
-
-
Taking out existing door motor and S&F motor for for 08 passenger lift. Make- Thyssen Krupp.
1
-
-
S&F in replacement the following items suitable for Johnsons 10 persons (680 Kgs) lift installed at SRE. Make-M/s Johnson Lifts Pvt Ltd.
-
-
-
Nylon roller ‘U’ assembly.
1
-
-
Nylon roller ‘V’ assembly.
1
-
-
Power door contact female.
1
-
-
Power door contact male.
1
-
-
Door SKATE (Fixed).
1
-
-
Door SKATE (Moving).
1
-
-
Door drive VVVF.
1
-
-
110 V DC relays 10 A FINDER.
1
-
-
SMPS 24 V, 6.5 A-DELTA.
1
-
-
SMPS 24 V/ 0.7A.
1
-
-
AC-DC Converters with battery charges - with DIN type.
1
-
-
SP2 Mother board with finder relay and FCI connector.
1
-
-
SP2 car board with finder relay and FCI connector.
1
-
-
Charger unit.
1
-
-
Hook assembly-R.H. (POD-Valance plate assembly).
1
-
-
Hook assembly-L.H. (POD-Valance plate assembly - Aschmersal Switch).
1
-
-
Door slipper (POD).
1
-
-
Screen sensor (WECO) with power supply unit).
1
-
-
Screen power supply unit WECO.
1
-
-
Screen sensor extension cable with 5 pin connector.
1
-
-
FUJI VVVF-FRN-5.5 MIS-4AA.
1
-
-
FUJI VVVF-OPC-LMI-PSI-Card.
1
-
-
Serial communication CPU-Cum-Display card (8952) POD SG221.
1
-
-
SG 235 7 SEG 1 Digit POD.
1
-
-
SG219 HWC POD.
1
-
-
SG 230 CPU (M).
1
-
-
CAR TOP REED Switch (3 way).
1
-
-
SG 107 landing interface.
1
-
-
SG 227 car CPU card – POD.
1
-
-
SG 221 Display cum comm. Card.
1
-
-
KDS brake power supply (Blue) CSC 2400 D (198/103 V DC, 2.0/ 1.1A/ 2401006).
1
-
-
25 A contactor 110 V DC.
1
-
-
CT1 contactor (32A) 2.5 KVA (H) UPS.
1
-
-
10A 110V DC contactor.
1
-
-
Logic board for (C) ARD 25 PIN.
1
-
-
FSR & main limit switch assembly NC type 1058/ 2138.
1
-
-
Notes for Ser item No 1&2
-
-
-
(a) The contractor shall be submit the Memorandum of Understanding (MOU) on stamp paper duly notarized with orginal Equipments Manufacturer (OEM) as applicable as per specification to the effect and maintanance shall be carried out under OEM overall supervision and direction/ instruction within 15 days of acceptance of tender, failing which the contract will be liable to be cancelled under condition 54 of IAFW-2249.
(b) The contractor shall provide of high skilled mechanic/operator joint during currency of contract period, if required. The cost of the same shall be deem to be included above quated rate. (c) In case new mechanic/operator joint during currency of contract period, the OEM or their accredited/authorised agencies shall be training to new mechanic.
(d) That for any break of terms and condition any condition of the MOU by contractor the OEM shall inform to GE.
-
-
-
(e) Contractor shall rectify the fault within 24 hours as per the direction of AGE E/M or his rep within design limit as specified in PS otherwise shall be recovery as specified in here-in-after.
(f) Make and model of part to be replaced shall be as existing at site or as per OEM recommendation.
(g) The cost of transportation and other necessary equipments shall be arranged/brought by contractor in this effect.
(h) Bidders are advised to inspect site of work and condition of lift before quoting their rates in consultation with concern executive.Nothing extra shall be admissible at any belated stage.
(j) Original service report for each lift dully signed by OEM Technician and user rep shall be submitted to Engineer-in-Charge.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements