Military Engineer Services Tender

View complete overview of Chandigarh MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date19 Jun 2024
Closing Date4 Sep 2024
Tender Amount₹ 82,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters (fixed type) without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised alumnium snap beading, screws etc. complete all as specified and as directed.

18

-

-

... More
S&F 4.8 mm thick sheet glass, ordinary quality and fixed with aluminum beading and gaskit suitable for aluminum frames in squares exceeding 0.5 sqm in each pane complete all as specified and as directed.

160

-

-

... More
M&L for 12 mm thick medium density fibre board, exterior grade, fixed with screws/ beading to aluminum frame work complete all as specified and as directed.

250

-

-

... More
M & L for 3mm thick ACP sheet, exterior grade, fixed with screws/ beadings to aluminium frame work complete all as specified and as directed.

65

-

-

... More
S&F for Double action floor spring Hydraucally regulated made up of minimum 1.25 mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.

20

-

-

... More
S&F Floor Door stopper 150 mm length of cover plate of aluminum alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor complete all as specified and as directed.

20

-

-

... More
S&F Mortice lock, vertical type, brass of size 100 mm with 4 leavers complete all as specified and as directed.

15

-

-

... More
S&F stainless steel wire cloth 0.36 mm nominal dia. of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or stainless steel wire staples including fixing with wooden fillet supplied with frame complete all as specified and as directed.

3.5

-

-

... More
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.

16

-

-

... More
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.

190

-

-

... More
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm complete all as specified and as directed.

11

-

-

... More
Removing excavated surplus soil to a distance n.exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.

33.5

-

-

... More
M&L for Broken stone or Boulders Hardcore of grading 2( 63 to 40 mm) deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and as directed .

28

-

-

... More
M&L for 100 mm thick plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.

190

-

-

... More
M&L for Providing and laying 60mm thick factory made, chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over & including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.

175

-

-

... More
Demolition of Brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and as directed.

5

-

-

... More
M&L for Brick work with old size sub class 'B' bricks straight or curved on plan exc. 6 Mtr mean radius built in cement mortar (1:4) complete all as specified and as directed.

17.5

-

-

... More
M&L for Fair cutting exc 10 cm width or grith (straight or raking cutting) on exposed surface of brick work, making good to facing where required and pointing in cement mortor 1:3 complete all as specified and as directed.

5

-

-

... More
Taking down cement plaster on brick or concrete surfaces incl racking out of joints, hacking for key, scrubbing down with water etc (upto three storey Building) complete all as specified and as directed.

100

-

-

... More
M&L for 15mm thick rendering on brick or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and as directed.

110

-

-

... More
M&L for 15mm thick rendering on brick or concrete surfaces in cement mortar 1:6 finished surface even and smooth without using extra cement complete all as specified and as directed.

115

-

-

... More
M&L for applying two coats of water based distemper on newly plastered surfaces of walls over a coat of primer (same manufacturer) over 2-3mm thick wall care putty with and including preparation of surfaces complete all as specified and as directed.

115

-

-

... More
M&L for applying two coats of Cement based paint over newly plastered surfaces of walls with and including preparation of new plastered surfaces complete all as specified and as directed.

110

-

-

... More
M&L for 5mm thick rendering in cement mortar 1:3 finished surface even and smooth without using extra cement complete all as specified and as directed.

16

-

-

... More
M&L for preparation of newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.

16

-

-

... More
S&F for steel Rolling shutters 1.25 mm thick, without ball bearing, gear operated type with chain wheel and hand chain including top cover, anchoring rod, hasp and staple, erected in position as indicated complete all as specified and as directed.

105

-

-

... More
M&L for preparation and applying two coats of synthetic enamel paint on new steel and iron surfaces of any description, over 10cm in width or girth over a coat of red oxide primer complete all as specified and as directed.

205

-

-

... More
M&L for PCC (1:4:8), type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.

5

-

-

... More
M&L for Reinforced cement concrete M-25 (Design mix) (using 20 mm graded stone aggregates) in foundations, including rafts, footings, foundation beams; plinth beams; bases for coloumns etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.

1.9

-

-

... More
M&L for Reinforced cement concrete M-25 (Design mix) (using 20 mm graded stone aggregates) in Columns, Pillars, piers, post and struts complete all as specified and as directed.

0.7

-

-

... More
M&L for Reinforced cement concrete M-25 (Design mix) (using 20 mm graded stone aggregates) in Beams, cantilevers, lintel over 1.5 mtr span complete all as specified and as directed.

1

-

-

... More
M&L for Reinforced cement concrete M-25 (Design mix) (using 20 mm graded stone aggregates) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.

5.5

-

-

... More
M&L for Use and waste of form work to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work; verticle or to batter for rough finished surfaces of concrete complete all as specified and as directed.

12

-

-

... More
M&L for Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete complete all as specified and as directed.

8

-

-

... More
M&L for Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, gridders, bressummers, lintels, cantileavers, shelves including suports, overhangs, splays between floors and beams etc for rough finished surfaces of concrete complete all as specified and as directed.

15

-

-

... More
M&L for Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs nexc 20 cm wide and side of RCC/ PCC bands in wallls, horizontal or sloping and similliar work exc 10 cm but n.exc 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed.

65

-

-

... More
M&L for Use and waste of form work to suspended slab such as roof slab, floor slabs, landings, and similar work: not exceeding 200 mm thick (Horizontal or sloping) for rough finished surfaces of concrete complete all as specified and as directed.

60

-

-

... More
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia or securing clips complete all as specified and as directed.

950

-

-

... More
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing unserviceable tiles to the low lying areas out side of MOD land to a place designated by the local administration complete all as specified and as directed.

78

-

-

... More
M&L for Machine cut pre polished Kota stone slab,18-20mm thick as in flooring, laid over and including cement screed bed 20mm thick in cement mortar (1:6), and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified & as directed.

17

-

-

... More
M&L for joint free non skid Coloured Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and as directed

36

-

-

... More
M&L for glazed ceramic (joint less) tiles coloured of size 450 x 300 x7 mm thick on vertical surfaces such as dados etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 10 mm thick screed bed in CM (1:4) complete all as specified and as directed.

190

-

-

... More
M&L for 18-20mm thick Granite (Z- black ) Superior quality stone work (table rubbed and polished) as on horrizontal/vertical surfaces such as cooking platforms, window cills, steps and the like, set in neat grey cement slurry @3Kg/Sqm, laid over and including 15mm thick bedding layer in cement mortar (1:6), with and including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.

16

-

-

... More
M&L for Solid PVC Wall lining consists of 5 mm thick single side prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and as directed.

240

-

-

... More
M&L for 5 mm thick PVC sheet fillet of width 35 mm thick for wall panelling inclusive of fixing on walls to make PVC frame complete all as specified and as directed.

460

-

-

... More
S&F Modular False ceiling with vinyl laminated gypsum tiles of size 595mmx595mmx8mm thick, tiles to be fixed with suspension system (Grid) of size 24mm x32mm, made of hot dipped galvanised steel section to prevent corrosion and the exposed surfaces of grid chemically cleaned capping prepainted/backed in polyester paint. The standared procedure for installation of grids is to be followed, where main runners of standard length of 3600 mm used along with cross section of 1200mm c/c. Wall angle (size 22mm x22mm) of the same quality as the grids to be used on the periphery along the wall or partition using screws at 600mm c/c and cross tee (24mmx23) to be interlocked between main runner at 600mm c/c (max) to form a grid of 600mm x600mm. The main runner to be hung from the sofit with the help of 4mm dia GI wire hanger and 6mm dia wire anchore fastner @ 1200mm c/c ( Max ) complete all as specified and as directed. Make : Diamond or equivalent model and Make specified here-in-after. Note : The work to be carried out through the rep of auth manufacturer's only.

150

-

-

... More
S&F Vitreous China (White) Kitchen/Laboratory Sink of size 450x300x150 mm with plug washer and wastes pipe; including bedding in cement mortor on dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and as directed.

1

-

-

... More
S&F 40 mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixed to waste pipe complete all as specified and as directed.

2

-

-

... More
S&F brass CP mixture for mixing hot and cold water, screwed down for iron pipe 15 mm bore complete all as specified as directed. Make: Prayag Cat No. 7350 or equivalent model of approved make specified here-in-after.

1

-

-

... More
S&F Angle/Stop valve chromium plated brass, fancy type screwed down, high pressure and fixed to iron pipe15 mm bore complete all as specified and as directed.

2

-

-

... More
S&F Angle/Stop valve (concealed type) chromium plated brass, fancy type screwed down, high pressure and fixed to iron pipe15 mm bore complete all as specified and as directed.

2

-

-

... More
S&F PVC connection 15mm size 450mm long with brass check nuts and PVC washers etc complete all as specified and as directed.

2

-

-

... More
S&F Chromium plated brass tubularTowel rail 20 mm dia, D type 60 cm long between flanges complete all as specified and as directed.

2

-

-

... More
S&F PVC (SWR) pipes 75 mm bore of pressure rating 6kgf/cm2 single socketed in any length with rubber ring joints laid in trenches or in floors or fixed to walls complete all as specified and as directed.

5

-

-

... More
S & F Rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and as directed.

100

-

-

... More
M&L for 18mm thick Block boards, grade 2 quality, interior grade, decorative type, with decorative face veneer on both faces, fixed with screws to hinges or timber frame-work complete all as specified and directed.

20

-

-

... More
S&F Butt hinges 40 mm size, heavy weight, cold rolled mild steel, and fixed complete all as specified and as directed.

55

-

-

... More
S&F 100 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.

10

-

-

... More
S&F 75 mm size Aluminium anodised Hasp and staple, safety type, including bolt to hinge plate and fixed with screws complete all as specified and as directed.

15

-

-

... More
S&F steel water tubing Galvanised 15mm bore (medium grade), incl all fittings and fixture fixed & concealed in wall or laid in floors complete all as specified and as directed.

20

-

-

... More
S&F extruded aluminium alloy handles of size 200mm, fabricated type complete all as specified and as directed.

16

-

-

... More
S&F 100mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.

18

-

-

... More
S&F 150mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.

16

-

-

... More
S&F Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.

4

-

-

... More
M&L for Preparation of new or previously untreated wood or wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.

40

-

-

... More
INTERNAL ELECTRIFICATION

-

-

-

... More
M&L for point wiring with 1.5 sqmm single core PVC insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through in and including stove enamelled steel conduit & accessories concealed in wall/fixed to roof ceiling etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLSH ISI marked as earth continuity conductor, fabrciated sunken terminal box made out of 1.22 mm thick sheet steel duly painted concealed in walls, with 3 mm thick bakelite sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan, regulators etc complete all as specified and as directed. Note :- (i) The chases in the wall shall be cut with elect cutter (ii) The disturbed surfaces of wall shall be made good with cement plaster 1: 4 including matching the surfaces with two coats of white wash/colour wash/distemper all as per existing finishes and to the entire satisfaction of Engr-in-Charge. (a) One light/fan point controlled by one, one way switch

8

-

-

... More
S&F Flame Proof Exhaust Fan 450 mm dia, single phase 240 volts with louvers (meeting the stringent requirements of Gas Groups IIA & IIB, engineered for use in hazarous & explosive area) complete with and inclding cutting hole in brick wall, finishing work and 04 Nos 12mm dia 150 mm long anchor fasteners complete all as specified and as directed.

2

-

-

... More
S&F Flame proof single pole one way switch 6 amps complete all as specified and as directed.

8

-

-

... More
S&F Flame Proof LED light fitting 2x16/20 Watt , CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures, driver, holders, connector etc. with all accessories, prewired with and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.

6

-

-

... More
S&F Flame proof/weatherproof plug in switch socket 16 amps, 3 pin (2P+E) complete all as specified and as directed.

16

-

-

... More
M&L for Sub main wiring with two single core 1.5 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including stove enamelled steel conduit surface type of size 20 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 1.5 Sqmm earth wire for earth continuity conductor complete all as specified and as directed. Note :- 2 runs of 1.5sqmm copper conductor phase and neutral and one run of same size earth wire including one run of stove enamelled steel conduit with cutting, chasing & making good shall be measured as one unit length.

400

-

-

... More
M&L for Sub main wiring with two single core 2.5 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including stove enamelled steel conduit surface type of size 20 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 2.5 Sqmm earth wire for earth continuity conductor complete all as specified and as directed. Note :- 2 runs of 2.5sqmm copper conductor phase and neutral and one run of same size earth wire including one run of stove enamelled steel conduit with cutting, chasing & making good shall be measured as one unit length.

200

-

-

... More
M&L for Sub main wiring with two single core 6 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including stove enamelled steel conduit surface type of size 20 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 6 Sqmm earth wire for earth continuity conductor complete all as specified and as directed. Note :- 2 runs of 6sqmm copper conductor phase and neutral and one run of same size earth wire including one run of stove enamelled steel conduit with cutting, chasing & making good shall be measured as one unit length.

300

-

-

... More
S&F FLP/WP distribution board TPN 4 ways with incoming MCB 4P 63 amps 01 No and outgoing MCBs 6-32 amps -12 Nos complete all as specified and as directed.

1

-

-

... More
S&F ceiling fans complete with blades, down rods, electronic regulator and accessoreis, 230V, 1400mm sweep, Min air delivery 210 CGM with service value 6.00 (BEE) Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.

1

-

-

... More
S&F exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, frame and louvers including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.

7

-

-

... More
S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, frame and louvers including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.

1

-

-

... More
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

55

-

-

... More
S&F switch piano flush button single pole one way, 6 Amps complete all as specified and as directed.

39

-

-

... More
S&F switch piano flush button single pole one way, 16 Amps complete all as specified and as directed.

12

-

-

... More
S&F socket outlet mulitpurpose 6 pin, 16 Amps, piano type complete all as specified and as directed.

12

-

-

... More
S&F heavy duty air circulator fans 230 volts single phase, oscillating 450mm sweep suitable for wall mounting consisting of 3 blades complete all as specified and as directed.

6

-

-

... More
S&F sheet metal enclosure single pole and neutral with two pin & earth plug and socket with & including SP, MCB 6-32 Amps, 240 volts 10 KA complete all as specified and as directed.

14

-

-

... More
S&F insulated Plug and Socket sheet steel enclosure 63 Amps with MCB, FP MCB metallic P&S 415 volts complete all as specified and as directed.

4

-

-

... More
M&L for point wiring with 1.5 sqmm single core PVC insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through in and including PVC conduit (medium grade) not less than 19mm dia & accessories concealed in wall/fixed to roof ceiling etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLSH ISI marked as earth continuity conductor, fabrciated sunken terminal box made out of 1.22 mm thick sheet steel duly painted concealed in walls, with 3 mm thick bakelite sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan, regulators etc complete all as specified and as directed. Note :- (i) The chases in the wall shall be cut with elect cutter (ii) The disturbed surfaces of wall shall be made good with cement plaster 1: 4 including matching the surfaces with two coats of white wash/colour wash/distemper all as per existing finishes and to the entire satisfaction of Engr-in-Charge. (a) One light/fan point controlled by one, one way switch

39

-

-

... More
All as per item No 89 here-in-before but with 2.5 sqmm single core PVC insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor for 3 pin 16 amps socket outlet on independent board including provision of 2.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLSH ISI marked as earth continuity conductor complete all as specified and as directed.

12

-

-

... More
S&F sheet metal enclosure suitable for MCCB as incoming VTPN 415 volts and outgoing MCBs (Factory made) double door, 4 ways with 200 Amp bus bar with IP43 protection with and including 100 amps FP 415 volts 16 KA MCCB - 01 No, MCB SP 240 volts 6-32 amps - 12 Nos complete all as specified and as directed.

4

-

-

... More
S&F rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of size 20 mm external dia complete all as specified and as directed.

200

-

-

... More
M&L for 4 mm dia galvanised iron or steel wire Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.

150

-

-

... More
S&F MCB SPN 240 Volts 40 Amps with over load protecton and rupturing capacity 10 KA, 'C' curve complete all as specified and as directed.

4

-

-

... More
S&F sheet metal enclosure (Factory made) double door DB SPN 240 Volts 8 ways for MCBs with IP 42 protection complete all as specified and as directed

10

-

-

... More
S&F MCB SP with over load protecton and rupturing capacity 10 KA, 'C' curve of rating 06 to 32 Amp single phase complete all as specified and as directed.

80

-

-

... More
M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5 m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized lead wire 4mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 15mm dia bore, and watering pipe 20 mm bore GI light grade pipe with funnel & wire mesh, including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, including taking out old earthing materials and removal complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI lead wire and protection pipe of length 7.5m, GI pipe beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.

14

-

-

... More
All as per item No 97 here-in-before but with galvanized steel strip 25x 4 mm size as earthing lead and 32 mm bore GI light grade protection pipe.

2

-

-

... More
Supply, installation, testing and commissioning of LT panel board (CPRI Approved) of suitable size factory made, compartment type, dust, water and vermin proof duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer, indoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out of 2.0 mm thick CRCA Sheet on angle iron frame and 4 Nos legs of angle iron 50 x 50 x 5mm, legs to be grouted in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable complete all as specified and comprising the following:- a)  LT bus bar aluminum TPN 400 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on epoxy insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 200 Amps,25 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 100 Amps, 25 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 02 No (d) 3 phase industrial type socket outlet 32 amp capacity - 01 N0 (e) MCB AC, SPN 20 Amps, 10 KA, 50 Hz, 240 Volts = 01 Nos. (f)   Digital Amps meter 96 x 96 mm flush mounting type with CT’s 200/5 A and selector switch= 01 Set. (g) Digital Voltmeter 0-500 volts 96 x 96 mm flush mounting type with selector switch =1Set. (h)  Phase indicator lamps RYB =01 Set (j) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc as per manufacturers design and specfification (k) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No and earthing terminals - 02 No

1

-

-

... More
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW of capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece Plastic 16 Amps 30mA PRCD shock proof plug top etc. complete all as specified and as directed.

2

-

-

... More
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 35 sqmm 3.5 core laid in trenches/ducts/through pipes/under culverts etc. complete all as specified and as directed.

350

-

-

... More
Taking down existing point wiring for light/power complete along with switches, sockets, regulators, ceiling roses, sunken boxes, sheets etc complete all as specified and as directed.

165

-

-

... More
M&L for point wiring with 1.5 sqmm single core PVC insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through in existing conduits including new sunken terminal boxes duly epoxy painted for mounting modular switch/sockets etc with and incl 1.5 Sqmm multi stranded copper conductor PVC insulated unshearthed FRLSH colour code cable 1100 volts grade for earth continuity for one light/fan point (through regulator), controlled by one switch complete all as specified and directed. Note :- (i) The chases in the wall shall be cut with elect cutter (ii) The disturbed surfaces of wall shall be made good with cement plaster 1: 4 including matching the surfaces with two coats of white wash/colour wash/distemper all as per existing finishes and to the entire satisfaction of Engr-in-Charge.

100

-

-

... More
All as per item No 103 here-in-before but one 5 amp socket outlet on independent board

25

-

-

... More
All as per item No 103 here-in-before but one 5 amp socket outlet on same board

10

-

-

... More
All as per item No 103 here-in-before but with 2.5 sqmm single core PVC insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor for 3 pin 16 amps socket outlet on independent board including provision of 2.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLSH ISI marked as earth continuity conductor complete all as specified and as directed.

30

-

-

... More
S&F Switch Modular type single pole one way 6 Amp one module complete all as specified and as directed.

135

-

-

... More
S&F Switch Modular type single pole one way 16 Amp one module complete all as specified and as directed.

30

-

-

... More
S&F Socket outlet Modular 3 pin 6/16 Amp multipurpose two modules complete all as specified and as directed.

30

-

-

... More
S&F Socket outlet Modular type 2/3 Pin combined 2 module single pole multi purpose 6 Amp complete all as specified and as directed.

35

-

-

... More
S&F Ceiling rose surface Bakelite 65 x 50 mm two to three terminals complete all as specified and as directed.

80

-

-

... More
S&F modular type step fan regulator suitable for 1200/1400 mm sweep ceiling fan 01 module complete all as specified and as directed.

25

-

-

... More
S&F LED luminaire 600 mm x 600 mm 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.

40

-

-

... More
S&F MCCB FP 160 amps 415 volts 25 KA with and including wall mounting type enclosure of suitable size and locking arrangement, fabricated out of 2mm thick CRCA sheet dully painted with synthetic enamel paint over a coat of redoxide with minimum 300 mm clearnce on top and bottom of MCCB complete all as specified and as directed.

1

-

-

... More
S&F modular type step fan regulator suitable for 1200/1400 mm sweep ceiling fan 02 modules complete all as specified and as directed.

1

-

-

... More
FIRE ALARM

-

-

-

... More
Taking down existing Fire Alarm, Smoke Detectors, Manual call points, Hooters etc including connecting wires and conduits etc complete all as specified and as directed.

50

-

-

... More
Taking down existing Fire Alarm Control Panel of any type and size complete all as specified and as directed.

1

-

-

... More
M&L for Fire Alarm Control Panel complying with BSEN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detectors and modules complete all as specified and as directed.

1

-

-

... More
M&L for Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 multisensor detector with heat and smoke combination complete all as specified and as directed.

25

-

-

... More
M&L for Addressable manual call point resettable type complete all as specified and as directed.

10

-

-

... More
M&L for Addressable sounder complete all as specified and as directed.

5

-

-

... More
Fixing only smoke detectors, Manual call points, Hooters etc complete all as specified and as directed.

15

-

-

... More
AIR CONDITIONING

-

-

-

... More
Supply, installation, testing and commissioning of split type AC ( Outdoor /inddor) of capacity 2 Ton 5 Star rating with inverter type with BEE 5 star, single phase, indoor and outdoor unit with cordless remote control and with in inbuilt air ionizer and plazma filter for better indoor air quality, necessary suction and discharge copper pipe line as per site requirement from inner unit to outer unit duly insulated with PVC/Thermocol laminated sheet including welding, brazing etc to make leak proof, suitable dia PVC pipe of superior quality for drainage of condensed water including stand for mounting outdoor unit as per company/manufacturer's instructions, manual etc with and including electric connection and electric cable from indoor unit to outdoor complete all as specified and as directed.

6

-

-

... More
S&F Voltage Stablizer for automatic operation with time delay relay and high/low voltage cut relay, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stablised at 230 V with accuracy of +/- 2.5% and of capacity 5 KVA complete all as specified and as directed.

8

-

-

... More
Supply, installation, testing and commissioning of Flameproof Split Type Air Conditioning unit electric driven single phase of capacity 2 TR complete including flameproof control panel, single phase, indoor and outdoor unit with cordless remote control and with in inbuilt air ionizer and plazma filter for better indoor air quality, necessary suction and discharge copper pipe line as per site requirement from inner unit to outer unit duly insulated with PVC/Thermocol laminated sheet including welding, brazing etc to make leak proof, suitable size/dia PVC pipe of superior quality for drainage of condensed water including stand for mounting outdoor unit as per company/manufacturer's instructions, Manual etc with and including electric connection and electric cable from indoor unit to outdoor complete all as specified and as directed.

2

-

-

... More
M&L for Sub main wiring with two single core 4 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including stove enamelled steel conduit surface type of size 25 mm dia or higher including Tee, junction, bends etc including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 4 Sqmm earth wire for earth continuity conductor complete all as specified and as directed. Note :- 2 runs of 4sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduit with cutting, chasing & making good shall be measured as one unit length.

800

-

-

... More
EXTERNAL WATER SUPPLY

-

-

-

... More
S&F steel tubes 25mm bore (medium grade) galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.

15

-

-

... More
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 25 mm bore of iron pipe or for unions complete all as specified and as directed.

6

-

-

... More
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 50mm bore of iron pipe or for unions complete all as specified and as directed.

1

-

-

... More
S&F galvanised iron union heavy duty for 25 mm bore of iron pipe complete all as specified and as directed.

6

-

-

... More
S&F galvanised iron union heavy duty for 50mm bore of iron pipe complete all as specified and as directed.

1

-

-

... More
S&F galvanised iron tank nipple 25 mm bore of iron pipe with fittings complete all as specified and as directed.

8

-

-

... More
S&F galvanised iron tank nipple 50 mm bore of iron pipe with fittings complete all as specified and as directed.

1

-

-

... More
M&L for Cutting/tapping of existing 25 mm bore galvanised iron pipe for branch connection complete all as specified and as directed

1

-

-

... More
S&F rotational moulded HDPE (triple layered) water storage tanks of capacity 1000 litres (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I with & including all fittings such as GI tank nipple etc. complete all as specified and as directed.

4

-

-

... More
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.

5

-

-

... More
S&F Cenrifugal Pump set 3 HP 1400/1500 RPM 3 phase 415 volts complete including control panel, DOL starter with SPP, electrical connections from starter upto pump set motor terminal block, inlet and outlet connections with medium grade galvanised iron pipe and fittings & gun metal gate vallve in suction and delivery, PCC foundation as per OEM's recommendations complete all as specified and as directed.

1

-

-

... More
Supply, laying, jointing and testing LT underground cable XLPE insulated, PVC sheathed, armoured heavy duty and 1100 volts grade with multi stranded aluminium conductor of size 16 sqmm 4 core in trenches/ducts/through pipes/under culverts etc. complete all as specified and as directed.

100

-

-

... More
S&F Double door type 4 way DB with and including 16 amps FP MCB and including incoming connections with four runs of 4 sqmm PVC insulated unsheathed single core copper conductor cable FRLSH 1100 volts grade laid through flexible PVC conduit heavy duty of 02 mtr length complete all as specified and as directed.

1

-

-

... More
S&F 63 mm dia 15 meter long hose pipe confirming to IS 636 complete with male and female brass couplings conforming to IS 903 complete all as specified and as directed.

28

-

-

... More
M&L for heavy duty PVC hose pipe 40 mm bore of length 100 RM with round clamps for fixing on pump set and a nozzle of suitable size on other end complete all as specified and as directed.

1

-

-

... More
S&F Ball brass valves, high pressure, with polythene float and flynut screwed for 25 mm bore of iron pipe or brass ferrule complete all as specified and as directed.

1

-

-

... More
LIGHTENING PROTECTION

-

-

-

... More
M&L for air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.

4

-

-

... More
M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.

100

-

-

... More
M&L for galvanised iron strip 32 x 6mm buried in ground complete all as specified and as directed.

25

-

-

... More
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3Nos. 8mm dia 25mm long hex. head screws complete all as specified and as directed.

4

-

-

... More
M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5 m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized steel strip 32x6mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20 mm bore GI light grade pipe with funnel & wire mesh, including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, including taking out old earthing materials and removal complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI steel strip and protection pipe of length 7.5m, GI pipe beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.

4

-

-

... More
Note: The Total amount shall subject to adjustment of credit of Rs 5595.00 for old Materials as per Schedule of Credit.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.