Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
MTC. OF E.I. IN NRB AT CHANDIGARH (REPLACEMENT OF PTS OF 11 KV VCB, BATTERY CHARGER AND HT CABLE IN CRICKET STADIUM, SECTOR 16, CHANDIGARH).
MTC. OF E.I. IN NRB AT CHANDIGARH (REPLACEMENT OF PTS OF 11 KV VCB, BATTERY CHARGER AND HT CABLE IN CRICKET STADIUM, SECTOR 16, CHANDIGARH).
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Repair and servicing of HT-OCB’s / VCB’s of 400 Amps. to 800 Amp. 350 MVA of various types of make. The job includes the dismantling of OCB’s/ VCB’s & reinstallation of the same in the control panel unit. (As per Complete Item No. 3 of the DNIT).

4

32000

8000

... More
Replacement of defective/ burnt out the following material in the existing HT/ LT panel. The new material shall be installed in the HT/ LT panel after the dismantling of old material by making the main panel in OFF order of suitable rating.

-

-

-

... More
LED indicator lamp of HT and LT panel of GE/ L&T/ Schneider make.

18

3240

180

... More
Repairing & Servicing of various type of ACB’s of various ratio from 800 Amp. to 1600 Amp. of various types of make. The job includes dismantling of ACB’s from L.T. panel, re-installation of the same after servicing in the LT control panel unit. The cost also includes lubrication of movable parts, replacement of minor parts during the serving job being done at site. The job includes doing the repair of U/V coil, Shunt coil etc.

7

20580

2940

... More
SITC of Intelligent multifunction digital meter to read V, A, KVA, KWH, THD, PF Hz, kVARh, Vah, VARh, MD, Import/Export and RS 485 port etc. with 3 Nos. resin cast CTs of 1600/5 A class 1.0 accuracy and 15 VA burden. The job include the cost of making connections with suitable size of Al. Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. Make:- Conzerv / Schneider / L&T / Siemens / Neptune / Enercon/ ABB only

4

12200

3050

... More
Supply & laying of PVC copper wire 2.5 mm sq. 3 core round sheathed wire on existing surface with suitable clamps/ hanger etc. including making connection and petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The copper wire should be of Polycab/ L&T/ Havells/ Finolex/ R.R. Kables make only.

40

7200

180

... More
Supply, Installation, Testing & Commissioning of Power Pack with 220 Volt AC supply input & 24 Volt DC continuous output, suitable for closing / tripping / indication of HT VCB breakers, provided with 2 Nos. 12 Volt each, (As per Complete Item No. 8 of the DNIT).

2

73144

36572

... More
Providing and fixing following rating MCCB 4 pole 415 Volt (Thermal magnetic / microprocessor release) without MS enclosure for Over load and short circuit protection, 36 KA Breaking capacity (Ics=100% Icu) with positive isolation. (As per Complete Item No. 9 of the DNIT).

-

-

-

... More
125 Amp 4 Pole MCCB (Thermal Magnetic release)

1

10825

10825

... More
200 Amp 4 Pole MCCB (Thermal Magnetic release)

1

24405

24405

... More
315/ 400 Amp 4 Pole MCCB (Microprocessor release)

1

35235

35235

... More
Digging of HT cable for locating fault approx. 1 Mtr. Below ground level. The job includes excavation removing the bricks from cable and refilling the trench in original finish after removing the fault

40

8000

200

... More
Supply and Erection of Fire Extinguishers ISI marked duly erected/ hung on wall with hooks including the cost of hooks with all material & labour required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work.

-

-

-

... More
CO2 type of 9 Kg capacity fire extinguishers conforming to IS.

6

96840

16140

... More
DSR Item No.10.4 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.

-

-

-

... More
50/ 70 sq. mm

4

50916

12729

... More
DSR Item No. 10.5 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required

-

-

-

... More
50/ 70 sq. mm

1

19069

19069



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.