Chandigarh Administration Tender
View complete overview of Chandigarh Chandigarh Administration Tender
Chandigarh Administration Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Sep 2024
Closing Date26 Sep 2024
Tender Amount₹ 5,07,054
Costs
EMD
₹ 10,150Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CHD_82494_1Bid Award Id
ViewTender No
E1/TN-205Tender Authority
Chandigarh Administration ViewPurchaser Address
-Website
http://http://chandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
MTC. OF E.I. IN NRB AT CHANDIGARH (REPLACEMENT OF PTS OF 11 KV VCB, BATTERY CHARGER AND HT CABLE IN CRICKET STADIUM, SECTOR 16, CHANDIGARH).
MTC. OF E.I. IN NRB AT CHANDIGARH (REPLACEMENT OF PTS OF 11 KV VCB, BATTERY CHARGER AND HT CABLE IN CRICKET STADIUM, SECTOR 16, CHANDIGARH).
BOQ Items
Repair and servicing of HT-OCB’s / VCB’s of 400 Amps. to 800 Amp. 350 MVA of various types of make. The job includes the dismantling of OCB’s/ VCB’s & reinstallation of the same in the control panel unit. (As per Complete Item No. 3 of the DNIT).
4
32000
8000
Replacement of defective/ burnt out the following material in the existing HT/ LT panel. The new material shall be installed in the HT/ LT panel after the dismantling of old material by making the main panel in OFF order of suitable rating.
-
-
-
LED indicator lamp of HT and LT panel of GE/ L&T/ Schneider make.
18
3240
180
Repairing & Servicing of various type of ACB’s of various ratio from 800 Amp. to 1600 Amp. of various types of make. The job includes dismantling of ACB’s from L.T. panel, re-installation of the same after servicing in the LT control panel unit. The cost also includes lubrication of movable parts, replacement of minor parts during the serving job being done at site. The job includes doing the repair of U/V coil, Shunt coil etc.
7
20580
2940
SITC of Intelligent multifunction digital meter to read V, A, KVA, KWH, THD, PF Hz, kVARh, Vah, VARh, MD, Import/Export and RS 485 port etc. with 3 Nos. resin cast CTs of 1600/5 A class 1.0 accuracy and 15 VA burden. The job include the cost of making connections with suitable size of Al. Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. Make:- Conzerv / Schneider / L&T / Siemens / Neptune / Enercon/ ABB only
4
12200
3050
Supply & laying of PVC copper wire 2.5 mm sq. 3 core round sheathed wire on existing surface with suitable clamps/ hanger etc. including making connection and petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The copper wire should be of Polycab/ L&T/ Havells/ Finolex/ R.R. Kables make only.
40
7200
180
Supply, Installation, Testing & Commissioning of Power Pack with 220 Volt AC supply input & 24 Volt DC continuous output, suitable for closing / tripping / indication of HT VCB breakers, provided with 2 Nos. 12 Volt each, (As per Complete Item No. 8 of the DNIT).
2
73144
36572
Providing and fixing following rating MCCB 4 pole 415 Volt (Thermal magnetic / microprocessor release) without MS enclosure for Over load and short circuit protection, 36 KA Breaking capacity (Ics=100% Icu) with positive isolation. (As per Complete Item No. 9 of the DNIT).
-
-
-
125 Amp 4 Pole MCCB (Thermal Magnetic release)
1
10825
10825
200 Amp 4 Pole MCCB (Thermal Magnetic release)
1
24405
24405
315/ 400 Amp 4 Pole MCCB (Microprocessor release)
1
35235
35235
Digging of HT cable for locating fault approx. 1 Mtr. Below ground level. The job includes excavation removing the bricks from cable and refilling the trench in original finish after removing the fault
40
8000
200
Supply and Erection of Fire Extinguishers ISI marked duly erected/ hung on wall with hooks including the cost of hooks with all material & labour required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work.
-
-
-
CO2 type of 9 Kg capacity fire extinguishers conforming to IS.
6
96840
16140
DSR Item No.10.4 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
-
-
-
50/ 70 sq. mm
4
50916
12729
DSR Item No. 10.5 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required
-
-
-
50/ 70 sq. mm
1
19069
19069