Chandigarh Administration Tender
View complete overview of Chandigarh Chandigarh Administration Tender
Chandigarh Administration Tender
Automobiles and Auto Parts
Eprocure
Opening Date6 May 2022
Closing Date12 May 2022
Tender Amount₹ 5,89,447 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 11,800Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_CHD_65766_1Bid Award Id
ViewTender No
E2/22/75Tender Authority
Chandigarh Administration ViewPurchaser Address
-Website
http://http://chandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Mtc. of E.I. in Govt. NRB at Chandigarh. (Replacement of defective chokes, starter, tube side holder and other accessories in examination centre in various schools under Electrical Sub Division No.2, Chandigarh for IAS preliminary exams to be held on 05.0
Mtc. of E.I. in Govt. NRB at Chandigarh. (Replacement of defective chokes, starter, tube side holder and other accessories in examination centre in various schools under Electrical Sub Division No.2, Chandigarh for IAS preliminary exams to be held on 05.0
BOQ Items
25 mm
50
-
90
DSR 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
-
-
-
3 x 1.5 sq.mm
300
-
54
3 x 2.5 sq.mm
200
-
75
3 x 4 sq.mm
90
-
117
DSR item No. 2.4: Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator)
-
-
-
4 way (4 + 12), Double door
5
-
3068
DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
-
-
-
Single pole
120
-
199
Triple pole and neutral
15
-
1092
Single pole and neutral
30
-
544
DSR 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
-
-
-
Group C
40
-
640
DSR 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required
-
-
-
5/6 amp. Switch
200
-
45
3 pin 5/6 amp. socket outlet
80
-
58
15/16 amps. Switch
80
-
110
6 pin 15/16 amp. socket outlet
80
-
128
Bell push
20
-
64
DSR item No. 1.24: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 amps switch
80
-
85
3 pin 5/6 amp socket outlet
50
-
111
15/16 amp switch
30
-
132
6 pin 15/16 amp socket outlet
30
-
175
DSR 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
6 way , Double door
7
-
1661
S/E of 3mm thick white glazed bakelite sheet on the existing M.S box. The job includes the cost of sheets and making holes and cutting charges of switches & sockets. The job includes the cost of all labuor& petty material required to complete the job.
30000
-
1.5
S/E of Bakelite holder ISI marked installed on exiting Jn. Box/ wooden block including connection etc as required. The holder should be of Anchor (Penta)/ Havells (Reo)/ Goldmedal (Eikon)/ SSK make only.
100
-
25
Supply, Erection, Testing and commissioning of the following accessories in existing fittings after dismantling the burnt out/ defective accessories with the help of ladder if required which shall be arranged by the firm at his own cost. The job includes cost of making connections with suitable rating copper wire and petty material required to complete the job to the entire satisfaction of Engineer-in-charge.
-
-
-
S/E of Copper wound ballast 36/40 Watt for existing tube light fitting. The material shall be of Philips / Bajaj / Wipro / GE make only.
40
-
230
S/E of Starter 20/40 watt. Of Philips / GE / Wipro / GE make only
400
-
18
S/E of tube side holders for 1x40/2x40 watt tube fittings.
100
-
20
S/E of electronic choke 36/40 watt for existing tube light fittings. The material shall be of Philips / Bajaj / Wipro / GE make only.
40
-
200
S/E of Copper wound ballast 150 Watt M.H. fitting. The material shall be of Philips make BSN 150x261 / Bajaj make BJOS 150 SV/MH / Wipro make WBS/H 57150 SL31* / GE make BVSM 150 only.
5
-
1150
S/E of Ignitor suitable for 150/250 watt HPSV /SON fitting. The ignitor should be of Philips make S I-51/SN-58/ Wipro make WEH35001 only.
5
-
450
S/E of Capacitor suitable for 150/250 Watt MH/HPSV fitting (20 mfd.). The capacitor should be of ISI marked Havells/ Crompton or its equivalent Bajaj/ Wipro make only
5
-
150
Providing and fixing following rating MCCB 4 pole 415 Volt (Thermal magnetic / microprocessor release) for Over load and short circuit protection, 36 KA Breaking capacity (Ics=100% Icu) with positive isolation. The overload & short circuit release shall be of adjustable type, suitable for isolation The MCCB is to be installed in existing cubicle panel / angle iron board/ VTPN BDB / MCCB enclosure including drilling holes in cubicle panel / angle iron board, making connections with suitable rating of copper wire / copper strip etc. as required. The job includes the cost of spreaders terminal links. The job also includes cost of MS enclosure or direct/ extended rotary handle etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The MCCB should be of L&T/ Siemens/ Schneider/ Legrand/ ABB make only.
-
-
-
100Amp 4 Pole MCCB (Thermal Magnetic release).
7
-
10150
250Amp 4 Pole MCCB (Thermal Magnetic release).
3
-
23180
400Amp 4 Pole MCCB (Microprocessor release).
2
-
37120
S/E of LED box type fittings made of CRCA Sheet. The fittings should be installed on existing surface. The tube rod should be of Philips/ Wipro/ Bajaj/ Twinkle/ Crompton/ Havells/ Jaquar make only. The batten for housing the tube rod should be of Philips/ Wipro/ Bajaj/ Twinkle/ Crompton/ Havells/ Jaquar make only. The job includes carriage, erection, making connections testing and commissioning of the fittings
-
-
-
Specification of LED fittings
Wattage of LED fittings As per following parameter.
Total lumens of the LED fittings Minimum 1980 lumen Diffuser Extrusion Aluminium heat sink with Polycarbonate diffuser. Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz Power factor Minimum 0.90 Luminaire efficacy 110 lm/w
Color rendering index
CRI shall be greater than 80 Working/ operating temperature 00 to + 450c or better Color temperature 60000K + 10%
Electronic Driver Drive current (LED)
As per OEM.
Operating voltage 140 V to 270 V AC supply or better Type of driver Constant current output driver THD Less than 15%
Surge Protection 2.5 KV minimum Efficiency Driver
85%
Protection
Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect. Fixture Should comply with LM 79 test from NABL/ UL accredited lab.
LED Type/ Make/ Model
Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 30,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. Life of LED
30000 burning hours at 70% lumen maintenance
30
-
700
S/E of LED box type fittings made of CRCA Sheet. The fittings should be installed on existing surface. The tube rod should be of Philips/ Wipro/ Bajaj/ Twinkle/ Crompton/ Havells/ Jaquarmake only. The batten for housing the 2 nos. tube rod should be of Philips/ Wipro/ Bajaj/ Twinkle/ Crompton/ Havells/ Jaquarmake only. The job includes carriage, erection, making connections testing and commissioning of the fittings
-
-
-
Specification of LED fittings
Wattage of LED fittings As per following parameter.
Total lumens of each tube rod Minimum 1980 lumen for each tube rod. Diffuser Extrusion Aluminium heat sink with Polycarbonate diffuser. Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz Power factor Minimum 0.90 Luminaire efficacy 110 lm/w
Color rendering index
CRI shall be greater than 80 Working/ operating temperature 00 to + 450c or better Color temperature 60000K + 10%
Electronic Driver Drive current (LED)
As per OEM.
Operating voltage 140 V to 270 V AC supply or better Type of driver Constant current output driver THD Less than 15%
Surge Protection 2.5 KV minimum Efficiency Driver
85%
Protection
Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect. Fixture Should comply with LM 79 test from NABL/ UL accredited lab.
LED Type/ Make/ Model
Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 30,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. Life of LED
30000 burning hours at 70% lumen maintenance
10
-
1140
Supply and fixing of following sizes of ISI marked medium class PVC batten along with accessories in surface.
-
-
-
20mm
100
-
18
25mm
50
-
20
S/L of PVC insulated sheathed aluminum conductor unamoured cable 10 sq.mm 2 core flat with 8 SWG GI wire on existing surface with suitable clamps/ hanger etc including making connection and petty material etc as required. The cable should be of Polycab/ Havells/ RR Kable/ KEI make only.
150
-
90
S/E of High Power LED Flood light luminaries of Philips / Bajaj / Wipro/ Twinkle/ Havells/ Crompton/ Jaquar make only. The job includes the cost of testing, commissioning and making connection with suitable rating copper wire from adjacent light point, other petty material and labour charges etc. as required to complete the same to the entire satisfaction of EIC.
-
-
-
Specification of LED fittings:
Wattage of LED fittings As per following parameter
Total lumens of the LED fittings Minimum 7000 lumen Ingress protection level of fittings IP 65 or better. Body of fittings Pressure dia cast aluminium body with Extruded Aluminium heat sink
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz Power factor Minimum 0.95
Luminaire efficacy 100 lm/w
Color rendering index
CRI shall 70 (minimum) Working/ operating temperature 00 to + 450c or better Color temperature 55000 K to 65000K
Electronic Driver Drive current (LED)
As per OEM Operating voltage 140 V to 270 V AC supply or better Type of driver Constant current output driver THD Less than 10%
Surge Protection 10 KV minimum Efficiency Driver
85%
Protection
Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect. Fixture Should comply with LM 79 test from NABL lab. LED Type/ Make/ Model
Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the original manufacturer. Life of LED
50000 burning hours
3
-
4350