Chandigarh Administration Tender

View complete overview of Chandigarh Chandigarh Administration Tender

Chandigarh Administration Tender

Works
Civil And Construction
Building Construction
Electrical Works
Eprocure
Opening Date17 Aug 2022
Closing Date23 Aug 2022
Tender Amount₹ 27,713 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DSR Item No. 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.

3

-

285

... More
DSR Item No. 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.

3

-

406

... More
DSR Item No. 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

4

-

65

... More
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

40

-

84

50

-

90

... More
DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 1.5 sq. mm

80

-

54

... More
3 x 2.5 sq. mm

50

-

75

... More
3 x 4 sq. mm

20

-

117

... More
2 x 6 sq. mm

2

-

122

... More
DSR item No.1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required

-

-

-

... More
5/6 amps switch

5

-

45

... More
3 Pin 5/6 A. socket outlet

5

-

58

... More
DSR Item No. 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

2

-

848

... More
DSR Item No.2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)

-

-

-

... More
8 Way, Double door

1

-

1760

... More
DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

8

-

199

... More
Supply and Erection of electronic step type socket type fan regulator in existing B.L. Sheet including making connection and petty material reqd. to complete the job. The fan regulator should be of Anchor Panta / Havells Reo/ Gold Medal Essenza make only

3

-

265

... More
Supply and Erection of B.L. Holder of make Anchor Panta / Havells Reo/ Gold Medal Essenza ISI marked on existing Jn. Box / Wooden block including making connection etc as required.

12

-

45

... More
Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making good the damage, Carriage Charges, connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.

-

-

-

... More
Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make HDEF EXHD 300-6-1/ Bajaj make Supreme DLX only.

1

-

4360

... More
Making hole for installation of exhaust fan of size upto 450 mm sweep by demolishing brick work manually / by mechanically means including disposal of Malba within 50 Mtr. lead and making good the wall by cement plastering etc. as required.

1

-

300

... More
S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The LED Bulk Head fitting should be of Philips / Wipro / Bajaj /Crompton / Havells /Panasonic/ Twinkle/ Trilux/ Jaquar/ LT/ Surya make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge.

1

-

1010



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.