Police Housing Corporation Limited Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Police Housing Corporation Limited Tender

Works
Eprocure
Opening Date17 Nov 2021
Closing Date25 Nov 2021
Tender Amount₹ 2,49,90,006 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DSR 2.7 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.

-

-

-

... More
DSR 2.7.3 Hard rock (blasting prohibited)

107.57

-

1028.09

... More
5.1.8 Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)

512.74

-

118.49

... More
5.1.10 Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)

95.66

-

415.58

... More
5.6.1 Providing designation 75 A one brick flat soling joints filles with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I

773.31

-

329.83

... More
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)

83.8

-

4492.36

... More
5.2.3 Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.

31.54

-

5069.99

... More
5.3.5 Providing and laying damp proof course 50mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand (zone III) : 4 graded stone aggregate 20mm nominal size).

37.41

-

269.23

... More
5.3.1.1 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone -III ) : 3 graded stone aggregate 20mm nominal Size)

89.84

-

4858.76

... More
5.3.17.1 Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete

233.17

-

184.61

... More
5.3.10 R.C.C. Work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and stru etc. Above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)

40.26

-

6972.73

... More
5.3.17.6 Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts

444.94

-

423.16

... More
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)

212.68

-

6092.63

... More
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick

1166.49

-

368.18

... More
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick

1130.21

-

455.61

... More
5.3.17.7 Centering and Shuttering including strutting, propping etc. And removal of form for Stairs, (excluding landing ) except spiral staircases

15.24

-

467.42

... More
5.3.17.19 Centering and Shuttering including strutting, propping etc. And removal of form for Weather shade, Chajja, corbels etc. Including edges

160.73

-

472.38

... More
5.2.14 Providing designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

52.25

-

5098.81

... More
5.2.50 Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in CM (1:3) in super structure with approved quality of Clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials raking our joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I

156.75

-

4720.87

... More
5.2.23 Providing designation 125mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse & of F.M. 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.

547.6

-

668.26

... More
5.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I

3953.73

-

153.24

... More
5.7.6 Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.

1117.24

-

170.27

... More
5.5.5 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. 8 mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)

14.58

-

79086.94

... More
5.5.5a 10mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)

7.1

-

77259.94

... More
5.5.5b 12mm dia - 20mm dia TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)

22.62

-

76041.94

... More
DSR 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mmdia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.

34

-

160.77

... More
5.7.21 Making 6x6 mm Groove in plaster surface over walls trully horizantal and vertical as specified as regular interval , at all heights including claening finishing scaffoolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I.

1429

-

96.23

... More
DSR 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

5363.23

-

107.51

... More
DSR 13.46.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

1829.12

-

144.84

... More
5.8.18 Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I.

3534.11

-

81.3

... More
DSR 22.22A Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.

519.38

-

411.6

... More
DSR 22.14 Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size)

32.72

-

6520.08

... More
JSOR {M-239(ii)} Providing & supplying Cico liquid / impermo water proofing compound in cement concrete or cement mortar @ 2% of cement quqntity by weight ( as specified) for water proofing, including all carraige and taxes .

50

-

144.08

... More
DSR 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

33.78

-

448.46

... More
DSR 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.).

699.58

-

531.49

... More
DSR 12.41.2 Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia

90

-

277.57

... More
DSR 12.42 Providing & fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion

-

-

-

... More
12.42.5.2 Bend -110 mm

8

-

114.58

... More
12.42.6.2 Shoe - 110mm

8

-

100.65

... More
DSR 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

40

-

268.67

... More
5.10.33 Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of earthwok involved with 75mm cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at th base, he drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.

106.7

-

1347.69

... More
DSR 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

74.12

-

591.74

... More
DSR 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

-

-

-

... More
DSR 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

687.31

-

497.76

... More
DSR 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness

81.58

-

885.28

... More
DSR 9.119 Providing and fixing factory made P.V.C. door frame manufactured by M/s Rajshri or equivalent of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers speci fication and direction of Engineer-in-Charge.-

96.9

-

354.4

... More
DSR 9.120.2 Providing and fixing 30 mm thick factory made PVC rigid foam panelled door shutters manufactured by M/s Rajshri or equivalent made from M.S. tube of 19 gauge thickness, size 19 x 19 mm for styles and 15 x 15 mm for top and bottom rails, covered with heat moulded PVC "C" channel of 5 mm thick and 75 mm wide PVC sheets for top rail, lock rail and bottom rail on either side and 5 mm thick, 20 mm wide cross PVC sheet as gap insert for top rail and bottom rial, panelling of 5 mm thick PVC sheet fitted in the M.S. frame welded/ sealed to the styles and rails with 5 x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineer-in-Charge fixed to frames with 4 Nos. M.S. powder coated butt hinges (For W.C. and bathroom shutters).

35.91

-

2131.27

... More
5.5.12 Supplying , fitting and fixing M.S. grill made of 20x6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted welded and finished smooth , hoisting as per building specification and direction of E/I.

1900.26

-

73.46

... More
DSR 10.14 Providing and fixing pressed steel door frames conforming to IS: 4351 manufactured from commercial mild steel of 1.60 mm thickness including hings , jamb , lock jamb, bead and if required angle threshold of mild steel angle od section 50x25mm or base ties of 1.60 mm pressed mild steel welded or rigidly togather by mechnical means including M.S pressed butt hiongs 2.5 mm thick with mortar guards , lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by Engineer - in-charge. Profile B

-

-

-

... More
10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb

144.87

-

385.87

... More
5.4.34 Supplying, fitting & fixing 30mm thick solid core type decorative single leaf flush door shutters in doors with both side decorative venier with black board core bended with high quality in all formaldehyde synthetic resin of standered with aluminium fittings such as hinges, tower bolts, handle, cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I.

63.32

-

1911.82

... More
DSR 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete 11.41.3 Size of Tile 800x800 mm

443

-

1631.98

... More
D.S.R 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 11.46.3 Size of Tile 800x800 mm

18.73

-

1677.82

... More
DSR 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

417.5

-

3393.22

... More
DSR 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.

110.46

-

992.06

... More
DSR 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

487.72

-

923.18

... More
DSR 8.2.2.2 Providing and fixing 18mm thick mirror polished, machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 Cement : 4 coarse sand) with joints treated with white cement ,mixed with matching pigment, epoxy touch ups, including rubbing ,curing etc. complete at all levels. GRANITE OF ANY COLOUR AND SHADE -Area of slab Over 0.5 sqm .

7.44

-

3841.64

... More
DSR 8.3 Providing edge moulding to 18 mm thick marble stone counters, Vanitiesetc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 8.3.2 Granite work

252.41

-

363.6

... More
5.6.19 Providing and laying 15 mm - 23mm thick Kotah stone slab riser steps of approved size, texture and colour over 19 mm thick base of lime morter (1:1:1 ) lime putty:surkhi:coarse sand over and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete job as per specifications and direction of E/I. (iv) 600 x 600 mm size

81.87

-

1671.24

... More
DSR 13.68 French spirit polishing : 13.68.1 Two or more coats on new works including a coat of wood

142.47

-

319.72

... More
5.8.41 Providing primer one coat of red lead paint ofapproved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.

157.1

-

53.49

... More
5.8.45 Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.

157.1

-

61.9

... More
DSR 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.1 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble

20.42

-

2523.08

... More
DSR 25.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:

-

-

-

... More
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, icrowave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:

-

-

-

... More
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.

-

-

-

... More
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.

-

-

-

... More
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science &Technologies, India. Cost of testing is payable separately.

-

-

-

... More
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO /IEC 17011 and accredits labs as per ISO/ IEC 17025.

-

-

-

... More
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm

-

-

-

... More
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

13.38

-

2700.96

... More
DSR 16.68 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

46.47

-

825.56

... More
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.

-

-

-

... More
Fly Ash Bricks 30 km

113.8

-

1251

... More
Bricks (70P+2k=72KM.)

37.93

-

2703.8

... More
Local Sand (10 KM.)

80.5

-

262.6

... More
Coarse Sand (30 KM.)

366.33

-

521.8

... More
Stone Chips (25) km

392.97

-

457

... More
Cement (10KM.)

213.26

-

360

... More
Steel ( 10 KM.)

44.3

-

360

... More
Earth ( 2 KM)

394.21

-

153.28

... More
Water Supply and Sanitary Installation work

-

-

-

... More
3.2.1 Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/ P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50 grms, 15mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specificatin and direction of E/I. (A) 580 mm long (C) with 10 ltrs. low level P.V.C. Cistern

6

-

3947.03

... More
3.2.2 Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C with Ptrap of parry/Hindustan or any other approved I.S.S make ineluding supplying and fixing 15 liters C.I mosquito proof low down flushing cistern of approved make with complete fittings with C.I handle and R.S or bracket wit h telescopic flush pipe with brass eoupling and plumbers joints spindle stop coci of approved quality weight not less than 450grams 15mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white /black plastic solid state seal and lead of commander / cuckoo or other I.S.S make with hinges or screws etc painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. (I) With 'P' trap (b) 10 Lit Law Lavel PVC Cistern.

7

-

4252.12

... More
DSR 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.9 White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked

19

-

3195.82

... More
DSR 17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

19

-

1302.19

... More
DSR 17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms

5

-

282.21

... More
DSR 18.52.1 Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931. 18.52.1 15mm nominal bore

8

-

516.3

... More
DSR 18.64 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms

11

-

92.14

... More
DSR 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

16

-

177.7

... More
DSR 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms

12

-

497.94

... More
3.2.3 Suppling, Fitting and Fixing Flat Back or angular, liped front viterous wide glazed earthen were urinal of Hindustan / Parrywere or any other approved ISI marked with 5 litres capacity C.I. automatic flushing cistern of reliance for any other ISI approved make with all fittings with CI or RS Brackets, Standard Size G.I. flush pipe with fitting clams 15mm CI buddy brass spindle stop cock of approved quality weight not less than 400 grms, 15 mm PVC / alkthene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a primer coat of red oxide cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I. (a) Flat back or standing corner (600mm x 350mm)

8

-

3590.98

... More
D.S.R 18.50 Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 810gms.

-

-

-

... More
18.50.1 15mm nominal bore

13

-

620.73

... More
D.S.R. 18.53 Providing and fixing C.P. brass angle valve for , gyser & others points of approved quality conforming to IS 8931. 18.53.1 15mm nominal bore, approved brand C.P. fittings.

64

-

434.35

... More
DSR 18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

29

-

83.98

... More
D.S.R. 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end )

-

-

-

... More
DSR 18.17.2 32 mm nominal bore.

4

-

512.09

... More
D.S.R. 18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.

-

-

-

... More
DSR 18.18.2 20mm nominal bore

4

-

345.02

... More
DSR 18.18.3 25mm nominal bore

4

-

346.5

... More
DSR 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

19

-

1225.01

... More
DSR 18.58 Providing and fixing PTMT grating of approved quality and colour.

-

-

-

... More
DSR 18.58.2 Rectangular type with openable circular lid DSR 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating

35

-

147.31

... More
DSR 17.10 Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required : DSR 17.10.1 Kitchen sink with drain board DSR 17.10.1.2 510x1040 mm bowl depth 225 mm

2

-

5796.65

... More
DSR 18.74 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 18.74.2 15 mm nominal bore with 45 cm length.

64

-

93.66

... More
DSR 17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia

11

-

5312.03

... More
DSR 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
12.41.1 75 mm diameter

50

-

184.9

... More
12.41.2 110 mm diameter

90

-

277.57

... More
D.S.R 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
DSR 12.42.1.1 Coupler 75 mm

25

-

69.27

... More
DSR 12.42.1.2 Coupler 110 mm

35

-

104.12

... More
DSR 12.42.2 Single pushfit Coupler

-

-

-

... More
DSR 12.42.2.1 75 mm

15

-

69.27

... More
DSR 12.42.2.2 110 mm

25

-

96.01

... More
DSR 12.42.3 Single tee with door

-

-

-

... More
DSR 12.42.3.1 75 X 75 X 75 mm

15

-

122.87

... More
DSR 12.42.3.2 110 X 110 X 110 mm

25

-

178.35

... More
DSR 12.42.4 Single tee without door

-

-

-

... More
DSR 12.42.4.1 75 X 75 X 75 mm

15

-

107.81

... More
DSR 12.42.4.2 110 X 110 X 110 mm

25

-

165.59

... More
DSR 12.42.5 Bend 87.5°

-

-

-

... More
DSR 12.42.5.1 75 mm Bend

25

-

79.69

... More
DSR 12.42.5.2 110 MM Bend

25

-

114.58

... More
D.S.R. 12.42.6 SHOE - 110MM

-

-

-

... More
DSR 12.42.6.1 75 MM

10

-

70.4

... More
DSR 12.42.6.2 110 MM Shoe

10

-

100.65

... More
D.S.R.12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
DSR 12.43.1 75 mm

33

-

269.84

... More
DSR 12.43.2 110 mm

77

-

268.67

... More
DSR 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME)

-

-

-

... More
Concealed work including cutting chases and making good the wall etc..

-

-

-

... More
DSR 18.8.1. 15mm dia

65

-

382.96

... More
DSR 18.8.2. 20mm dia

80

-

445.98

... More
DSR 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Exposed on Wall

-

-

-

... More
DSR 18.7.3 25 mm nominal outer dia Pipes

65

-

354.66

... More
DSR 18.7.4 32 mm nominal outer dia Pipes

100

-

434.87

... More
DSR 19.6 Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete.

-

-

-

... More
DSR 19.6.2 150 mm dia R.C.C. pipe

100

-

428.06

... More
D.S.R. 19.30 Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:

-

-

-

... More
19.30.1.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

20

-

5583.01

... More
Analysed and Approved Providing and Fixing Hand Shower ( Health Faucet) ( ABS Body) ALD-CHR-585 Jaquar made. Hand Shower with 1 meter Long Easy Flex Tube in Chrome Finish & Wall Hook.

7

-

1156.25

... More
Analysed and Approved Pvc trap including all fittings

60

-

315

... More
D.S.R 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

8000

-

8.42

... More
Septic tank

-

-

-

... More
5.1.1 Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing ro

46.19

-

139.58

... More
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)

46.19

-

14.26

... More
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe

1.4

-

415.58

... More
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)

2.8

-

4492.36

... More
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I

17.64

-

329.83

... More
5.2.2 Providing designation 75A brick work in C.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curri

9.83

-

5262.05

... More
5.2.23 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out

6.9

-

668.26

... More
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)

1.82

-

6092.63

... More
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick

19.98

-

455.61

... More
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)

0.39

-

6092.63

... More
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick

6.86

-

368.18

... More
5.7.2 Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I

54.7

-

162.13

... More
5.7.11 Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.

81.85

-

51.66

... More
Basic Rate of SOR 2021 M-198 (page no 44) Providing and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.

4.95

-

519.75

... More
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet

0.1

-

79086.94

... More
5.5.5 Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio

-

-

-

... More
(a) 10 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )

0.09

-

77259.94

... More
DSR 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.2 110 mm diameter

6

-

277.57

... More
Basic Rate of DW & SD SL NO 31(b) M 947 Supplying, fitting and fixing C.I. cover with frame for mane hole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I. (a) Size 600 x 450 mm (Wt. 25 Kg).

4

-

1610

... More
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.

-

-

-

... More
Bricks (70P+2k=72KM.)

6.58

-

2703.8

... More
Coarse Sand (30 KM.)

6.47

-

521.8

... More
Stone Chips (25) km

5.53

-

457

... More
Cement (10KM.)

2.94

-

360

... More
Steel ( 10 KM.)

0.89

-

360

... More
Section III 200x150xmm dia Deep bore Well With Pump set & electrification etc works.

-

-

-

... More
WD & SD Basic rate item no. 119 M 1035 Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site.

-

-

-

... More
From 0.0M to 50.0 M belew G.L

50

-

867.57

... More
From 51.0 M to200.00 M belew G.L

150

-

994.52

... More
DW& SD Basic rate item no. 120 M 1036 supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job.

20

-

1617

... More
DW& SD Basic rate item no. 126 M 1042 Cleaning Flushing and devloping of drilled hole for testing the discharge of water development of bore well by continueous flow of water bu using heavy compresser upto satisfaction of E/I. To get uniterrupted flow of water free from sand and soil etc.

1

-

3297.18

... More
DW& SD Basic rate item no. 120 M 1036 Supplying and fitting M.S cap over 200mm dia casing pipe as per direction of E/I .

1

-

231

... More
WD & SD Basic rate item no. 139 M 1055 Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.

-

-

-

... More
Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages 2.0 HP

1

-

25394.99

... More
WD & SD Basic rate item no. 149 M 1065 Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914. F.A.S.D. Starter

1

-

8697.15

... More
WD & SD Basic rate item no.146 M1062 Supplying 3 core flat flexible submersible cable with, copper conductor, PVC insulated and PVC sheathed as per IS : 7098 3 Core 4mm thick

130

-

130.52

... More
Rate Analiysed and Approved 2no heavy duty clamp 40mm dia duitable for pipe with all complet job.

2

-

1996.5

... More
WD & SD Basic rate item no. 14(K) (v) Supplying & lowering 40mm da column G. I. pipe with all complete job.

70

-

288.75

... More
Approach road (50 mtr)

-

-

-

... More
3.1 Excavation in Soil by Manual means. (Excavation for foadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 metres.) (ii) Including Royalty @ Rs. 27.48 per cum the cost of watering, rolling & compaction (i) Rolling with vibratory roller

150

-

262

... More
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe

62.5

-

415.58

... More
5.6.2 Providing designation 75 A one brick edge soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I

250

-

525.92

... More
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)

33.75

-

4492.36

... More
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.

-

-

-

... More
Bricks (70P+2k=72KM.)

13.5

-

2703.8

... More
Local Sand (10 KM.)

70

-

262.6

... More
Coarse Sand (30 KM.)

14.51

-

521.8

... More
Stone Chips (25) km

29.03

-

457

... More
Cement (10KM.)

13.91

-

360

... More
Concertina coil fencing (1493'00" ft)

-

-

-

... More
5.10.8 Dismantling Barbed wire fencing with ballah or angle iron post including stacking all materials in coountable stacks within 50 mtr lead all complete as direction of E/I.

615

-

19.18

... More
5.1.1 EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in hard soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I

64.04

-

139.58

... More
3.3.1.4 Providing P.C.C. M-10 with nominal mix of (1:3:6) in Foundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I.

64.04

-

3985.04

... More
Approved basic rates of material item No. 29+ 10%C.P. Supplying of M.S.ANGLE OF 50X50X6 for support of Concertina wire including all carriage, taxes, all complete.

4.45

-

50600

... More
5.5.24 Labour for cutting of M.S. angle iron post to required length& fixing in column , one end spitted as fishtailed in length of 150mm complete as per building specification & direction of E/I.

395.28

-

25.92

... More
5.5.23 Drilling 6 mm dia holes M.S. angle iron for fixing of staples etc. as per building specification & direction of E/I.

1976.41

-

8.3

... More
Approved basic rates of material item No. 3 (b)+ 10%C.P. Suplying of galvonised barbed wire of 4 points, 2 ply 12 SWG, 150 apart for fencing.

1061.39

-

69.09

... More
5.5.22 Labour for fitting & fixing barbed wire fencing in six rows horizontal up to a height of 1.25 M & two diagonals including fixing of post in cement concrete at 2.5 M centres including cost of staples (but excluding the cost of cement concrete angle iron post its cutting & making holes ,nuts & bolts ) all complete as per building specification & direction of E/ I.

860.59

-

67.4

... More
DSR16.53 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)

1290.88

-

263.6

... More
5.8.41 Providing primer one coat of red lead paint of approved make over steel surfce including preparing the surface after cleaning removing dust , dirt. Scales smokes & grease & cleaning the surface throughly including cost of scaffolding & taxes all complete as per building specification & direction of E/I. ( Mode of measurement of area shall be multiple by the co-efficient as indicated in building specification.)

159.92

-

53.49

... More
5.8.45 Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.

159.92

-

61.9

... More
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.

-

-

-

... More
Coarse Sand (30 KM.)

30.1

-

521.8

... More
Stone Chips (25) km

60.19

-

457

... More
Gate

-

-

-

... More
5.1.1 Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.

12.98

-

139.58

... More
5.1.2 Extra for earth work in hard soil as per specification and direction of E/I.( vide classification of soil item B)

12.98

-

14.26

... More
5.1.10 Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)

0.7

-

415.58

... More
5.6.1 Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.

7.01

-

329.83

... More
5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- all work up to plinth level- Foundation

-

-

-

... More
5.3.1.4 1:3:6 ( 1 cement : 3 coarse sand ( zone - III) ;6 graded stone aggregate 20 mm nominal size).

0.7

-

3985.04

... More
5.3.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering,finishing and reinforcement. All work up to plinth level ( foundation)

-

-

-

... More
5.3.9.1 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size)

2.54

-

5094.36

... More
5.3.17 Centering and shuttering including strutting,propping etc and removal of form for

-

-

-

... More
5.3.17.1 Foundations,footings,bases of columns etc for mass concrete

7.06

-

184.61

... More
5.3.10 Reinforced cement concrete work in walls ( any thickness),including attached pilasters,buttresses,plinth and string courses,fillets,columns,pillars,piers,abutments,posts and struts etc . above plinth level up to floor five level excluding cost of centering,shuttering ,finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size)

2.21

-

5891.97

... More
5.3.17 Centering and shuttering including strutting,propping etc and removal of form for

-

-

-

... More
5.3.17.6 Columns,pillars,piers,abutments,posts and struts

21.78

-

423.16

... More
5.3.11 Reinforced cement concrete work in beam ,suspended floors,roofs having slope up to 15 landing ,balconies,shelves,chajjas,lintels,bands,plainwindow sills,staircases and spiral stair cases above plinth level up to floor five level,excluding cost of centering,shuttering ,finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size)

3.71

-

6092.63

... More
5.3.17 Centering and shuttering including strutting,propping etc and removal of form for

-

-

-

... More
5.3.17.5 Lintels ,beams,plinth beams,girders,bressumers and cantilevers

24.83

-

337.71

... More
5.2.3 Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.

4.98

-

5069.99

... More
5.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I

99.58

-

153.24

... More
DSR 13.46.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

99.58

-

144.84

... More
(5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet

0.3

-

79086.94

... More
5.5.5 Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio

-

-

-

... More
(b) 12 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )

0.25

-

76041.94

... More
(c) 16 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )

0.45

-

76041.94

... More
5.5.29 Supplying,fitting and fixing 20 guage G.C.l. sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1".2.4 ) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specrfication and direction of E/|

18.32

-

3680.37

... More
5.8.41 Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.)

36.64

-

53.49

... More
5.8.45 Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I

36.64

-

61.9

... More
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.

-

-

-

... More
Bricks (70P+2k=72KM.)

0.27

-

2703.8

... More
Coarse Sand (30 KM.)

6.34

-

521.8

... More
Stone Chips (25) km

7.95

-

457

... More
Cement (10KM.)

1.69

-

360

... More
Steel ( 10 KM.)

1

-

360

... More
Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Anchor (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ (4)Switches/soket outlet for modular type:- Anchor (roma)/Havells(cabtree)Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell's/L&T/C&S (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard (7) LED ITTING FIXTURE -: Havells/Bajaj/Crompton (Model/as per E/I ) (8) CEALING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha / Crompton (Model/as per E/I ) (9)OCTAGONAL POLE-: Bajaj/Philips/Surya (10) CHEMICAL EARTHING OF MAKE - TRUEPOWER EARTHING (11) CENTRALISED AIR CONDITIONING OF MAKE - VOLTAS/MITSHUBISHI/ TOSHIBA/DAIKIN (12)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED

-

-

-

... More
1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.

-

-

-

... More
1.3.1 Group A

108

-

543

... More
1.3.2 Group B

112

-

625

... More
1.4 Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.

3

-

824

... More
1.5 Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.

700

-

231

... More
1.7 Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required

-

-

-

... More
1.7.2 2x2.5 sq mm+1x2.5 sq mm earth wire

650

-

173

... More
1.7.5 2x10 sq mm+1x10 sq mm earth wire

47

-

382

... More
1.7.10 4x6 sq mm+2x6 sq mm earth wire

220

-

561

... More
1.7.11 4x10 sq mm+2x10 sq mm earth wire

198

-

695

... More
1.16 Teliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required

-

-

-

... More
1.16.3 3 Pair

270

-

44

... More
1.17 TV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,with PVC sheath in the existing recessed PVC conduit as required.

90

-

37

... More
1.21 S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .

-

-

-

... More
1.21.1 20mm

310

-

52

... More
1.24 S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required

-

-

-

... More
1.24.1 5/6 amps, one way switch

81

-

60

... More
1.24.3 15/16 amps, one way switch

8

-

90

... More
1.24.4 5/6 amps, 3 pin socket outlet

81

-

77

... More
1.24.5 15/16 amp 6 pin socket outlet

8

-

128

... More
1.24.7 Teliphone socket with shutter outlet

14

-

73

... More
1.24.8 TV socket socket outlet

3

-

73

... More
1.25 S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.

32

-

256

... More
1.26 S/F Modular type blanking plate:-Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc, as required.

20

-

19

... More
1.27 S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.

-

-

-

... More
1.27.1 1 or 2 module(78mm x 78mm x 45mm)

33

-

152

... More
1.27.3 6 module(78mm x 205mm x 50mm)

28

-

215

... More
1.27.4 8/9 module(78mm x 230mm x 60mm)

4

-

259

... More
1.32 S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.

45

-

359

... More
1.33 S/F ceiling rose:- Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.

109

-

41

... More
1.34 S/F Batten holder:- Supplying and fixing batten/angle holder including connection etc, as required.

3

-

55

... More
1.36 S/F Dingdong Call bell :- Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required.

3

-

130

... More
1.41 ITC fluorescent/LED fitting directly on surface:- Instaliation, testing and commissioning of prewired, fluorescent fitting of all types, complete with all accessosries and tube etc. directly on ceiling /wall including connection with 1.5 sq mm.FR PVC insulated, copper conductor.

142

-

97

... More
1.44 ITC ceiling/wall fan:- Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required

48

-

101

... More
1.48 ITC exhaust fan up to 450 mm, sweep:- Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.

13

-

56

... More
2.8 S/F S.P. MCB DB:- Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)

-

-

-

... More
2.8.8 8 Way,Double door

1

-

986

... More
2.9 S/F T.P.MCB DB:- Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)

-

-

-

... More
2.9.4 4 way (4+12),Double door, Horizontal type

8

-

1848

... More
2.11S/F 'B' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.

-

-

-

... More
2.11.1 6/32 amps,single pole, "B" SERIES

52

-

163

... More
2.12 S/F 'C' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.

-

-

-

... More
2.12.1 6/32 amps,single pole, "C" SERIES

41

-

160

... More
2.12.6 40 amps ,DP

1

-

590

... More
2.16.9 40 amps,TPN

4

-

1136

... More
2.12.10 50/63 amps, TPN

4

-

1136

... More
2.13 S/F SP MCB blanking plate:- Supplying and fixing Single pole blanking plate in exiting MCB DB complete etc as required.

4

-

7

... More
2.19 P/F M.V. danger notice plate:- Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.

1

-

150

... More
3.7 S/L 8 SWG copper wire ground :- Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.

20

-

122

... More
4.2 P/F G.I. lightning conductor finial:- Providing and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.

5

-

291

... More
4.4 Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required.

15

-

57

... More
4.7 P/F G.I. lightning conductor tape in horizontal run:- Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run)

135

-

63

... More
4.8 P/F G.I lightning conductor tape in vertical run:- Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run)

49

-

94

... More
5.1 MV cable laying upto 35 sq.mm. in ground:- Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.

135

-

185

... More
5.2 MV cable laying upto 95 sq.mm. in ground:- Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding 95 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.

105

-

192

... More
DSR 11.3 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required 11.3.2 Above 6.5 metre and upto 8.0 metre

6

-

4657.36

... More
S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1)

-

-

-

... More
M-741 16 sq.mm. 4 core

130

-

154.67

... More
M-328 50 sq.mm. 3.5 core

20

-

433.74

... More
M-330 95 sq.mm. 3.5 core

120

-

728.28

... More
DSR 12.37 Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required

2

-

1217

... More
DSR9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
DSR9.1.33 4 X 16 sq. mm (28mm)

9

-

255

... More
DSR9.1.22 3½ X 50 sq. mm (35mm)

2

-

354

... More
DSR9.1.24 3½ X 95 sq. mm (45mm)

2

-

482

... More
FIXTURE AND CHEMICAL EARTHING

-

-

-

... More
M-775 Providing of 12'' (300 mm)exhaust fan of make bajaj/havells/usha/crompton

13

-

1179.66

... More
9.4 SITC of following size ceilling fan 3 blades confirming to IS :374:219 including wiring the down rods standard length ( up to 30 cm with 1.5 sqmm FRPVC insulated copper wire suitable for 230 volt 50Hz single phase supply etc complet as required of make Havells,Bajaj,Crompton,Polar 9.4.1 1200 mm (48") Ceilling fan

35

-

1522

... More
M-778 Providing of 16'' (400 mm) Wall fan of make bajaj/havells/usha/crompton

16

-

2126.98

... More
M-856 Supplying and fixing of LED 15/16 W of make bajaj/havells/crompton

52

-

173.43

... More
9.1 SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY _110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.

-

-

-

... More
9.1.7 SITC of LED street light (90/100 watt) of make bajaj/havells/crompton

4

-

7516

... More
9.2 S.I.T.C of following rating LED FLOOD lighting with pressure dia cast housing and toughened glass cover (IP 66 protection)in existing pole/pipe /platform/periferial wall for supply voltage 100-270v AC,50Hz Luminire shall be confirmto IS-10322 part-5/ section-3 and shall be complete with all neccssary accessories as required.of make bajaj/havells/crompton

-

-

-

... More
9.2.5 120 W LED FLOOD LIGHT of make bajaj/havells/crompton/C&S

6

-

9967

... More
M-869 Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton

3

-

375.93

... More
9.5 S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230 volt 50 Hz single phase supply etc complet as required of make Havells,Bajaj,Crompton, C & S 9.5.1 10/12 watt Tube light

2

-

523

... More
9.5 S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230 volt 50 Hz single phase supply etc complet as required of make Havells,Bajaj,Crompton, C & S 9.5.2 20/22 watt Tube light

65

-

657

... More
M-856 Supplying and fixing of LED 15/16 W of make bajaj/havells/crompton

6

-

172.43

... More
3.6 Earthing with copper earth plate 600x600x3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc (with charcoal or coke and salt) as required…..

8

-

9163

... More
M-742 Supplying and fixing of 7 Mtr height octagomal Hot-Dip Galvanized pole (BOP-7030) with top dia 70 mm,bottom dia 130mm & made of 3 mm thick sheet ,base plate diamentions 200 MM X 200 MM X 12 MM (LxBxT) including suitable size of foundetion bolt and 1'6'' long 50mmX50mm MS angle along with welded horizontally on top of octagonal pole all complete on exiting concreat platform as required OF MAKE BAJAJ/SURYA/PHILIPS

6

-

11770.88

... More
M-758 Supplying and fixing of 1.5 mtr single arm suitable for 70 mm top of existing Octagonal pole OF MAKE BAJAJ/SURYA/PHILIPS

6

-

2093.14

... More
Anaylised & Approved Supplying fitting fixing testing and commisioning of Water pump controlar for single phase submerssible motor with sensor as required of make AQUATECH/MAXTAN TECHNOLGIES/RMG AUTO PUMP CONTROLAR

1

-

15208.75

... More
1.16 Teliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required (FOR WATER PUMP CONTROLAR WIRING)

-

-

-

... More
1.16.3 4 Pair

90

-

44

... More
1.21 S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . (FOR WATER PUMP GONTROLAR WIRING)

-

-

-

... More
1.21.1 20mm

85

-

52

... More
DSR 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Make- Legrand, Schneider- Digilink.

102

-

33

... More
Analaysed & Approved Main Panel : Supplying fixing testing commissioning of 16 swg crca sheey steel panel box including painting, copper wiring, CT,PT,digital ampmeter,volt meter,copper basbar(40mmx6mm) 3 set, MCCB 4 pole 35 KA 1No,MCB 4 POLE 63 AMP 4 Nos,MCCB 4POLE 40 AMP 5 Nos, DP 40 AMP3 NOs,SP 16 AMP 2 NOs,contactor 4 pole 80 amp 1no, contractorh 4 pole 63 amp 1no,slector switch 2nos,surge protectin device 1 nos, push botton 2 nos, RYB INDICATOR 3 NOs, etc as required

1

-

168250

... More
CCTV

-

-

-

... More
1.27 Supplying and fixing following size /modules G.I. box along with modular base and cover plate for modular switches in recess etc. as required

-

-

-

... More
1.27.1 1 or 2 modules (78mmx78mmx45mm)

8

-

152

... More
Analaysed & Approved Providing, drawing, fitting, fixing, connecting and testing of indoor/ outdoor 1/3" SONY Effo E, 650 TVL OLUX ,External Adujustable IR Camera,28-12mm built-in iris lens,with 36 pcsIR LED. IR 40m, IP-66 including connections along with all standard accessories, i,e complete in all respect. Make-BOSCH. EVER FOCUS / TOSHIBA / PERITO / PANSONIC Featues 1. 1/3" Color SONY Super Had II Day & Night CCD Sensor. 2. Razor Sharp High Resolution: 650 TV Lines (Color) 3. 35 IR LED's enable vieing in total darkness up to 75 FT. 4. 0 Lux at IR on. 5. 2.8-12 EXTERNBAL adjustable Vari-focal lens. 6. 2DDNR (2D Digital Noise Reduction) 7. Weatherproof. 8. Compact & Light Weight . 9. Vandal-resistant: Polycarbonate Cover & Metal Body. 10. DC 12V

8

-

3360

... More
Analaysed & Approved Providing, fitting, fixing, connecting and testing of 8 Ch. Video and audio in put, 8 SATA interfaces, 4CIF/2CIF, 6 fps/Ch,alarm,I/O 16/4 along with all standard accessories complete in all respect with required size of wall mount rack. Make- BOSCH/EVER FOCUS/ Hik- VISION/ PERITO. Key features :- DS-8104/8108/8116HDI-ST Standalone DVR. H.264 video compression. HDMI and VGA output at up to 1920 x 1080 P resolution. Dual Stream 4/8/16 CH Sychronous playback. HDD quota and group management

1

-

18318

... More
Rear panel of DS 8116 HDI-ST Video in Audio in Video spot out Video out Audio out Line in RS 232 serial interface VGA interface HDMI interface eSATA interface LAN interface Terminal switch RS-485 serial interface, keyboard interface, alarm in, alarm out GND 100-240 VAC power input Power switch

-

-

-

... More
Analaysed & Approved Supply, fitting, fixing, commissioning and testing 32" LED colour Full HD TV totally flat full HD, resolution-1920 x 1080 with 2 x HDMI, 1 x USB, remote control & battery for remote control along with all accessories & 1 year warranty. for Live View and Replay of Recorded View HD TV Make:- Make:- Sony Model: KLV-32R482B / Samsung Model: 32J5300 / LG Model: 32LF560T.

1

-

24515.7

... More
Analaysed & Approved Providing, fitting, fixing, connecting and tesing of 4 Port video switcher, cable, along with all standard accessories complete in all respect. Make-Good Local Brand.

1

-

2590

... More
Analaysed & Approved Providing of NAS storage 2TB internal HDD along with all standard accessories complete in all respect. Make- DLINK/SEAGATE/WESTERN-DIGITAL.

1

-

6928.35

... More
Analaysed & Approved Providing, fitting, fixing, connecting and testing of 12 V DC 10 Amp. Charger along with all standard accessories complete in all respect. Make- Good Local Brand.

1

-

4476.95

... More
1.21 S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .

-

-

-

... More
1.21.2 25mm

265

-

58

... More
Analaysed & Approved Wiring and commisioningof 3+1 video cable and Power copper cable for entire CCTV in existing 2mm thick 25mm PVC Pipe surface/ recess with all accessosories as required..

180

-

44.8

... More
Rain Water Harvesting

-

-

-

... More
5.1.1 Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.

18.08

-

139.58

... More
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)

18.08

-

14.26

... More
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)

4.07

-

415.58

... More
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I

1.88

-

329.83

... More
5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.3.1.3 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)

0.85

-

4262.25

... More
5.2.2 Providing designation 75A brick work in C.M (1: 4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.

7.54

-

5262.05

... More
SOR Page 36 of Itm no M-009 & 10% CP Stone Metal at quarry site .. Traxes and royalty all complete as per building specification and direction of E/I. 90 mm Gravel filling

-

-

-

... More
0.90 M stone Boulder filling

5.15

-

674.37

... More
5.3.20 Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

0.75

-

12224.58

... More
5.7.1 Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

6.21

-

169.18

... More
5.7.6 Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.

6.21

-

170.27

... More
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (TMT Fe 500 (Only valid for SAIL & TATA Steel )

0.11

-

79086.94

... More
DSR 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter

31.8

-

277.57

... More
DSR 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
( 12.42.5.2) 110 mm bend

8

-

114.59

... More
( 12.42.6.2) Shoe 110 mm

2

-

100.66

... More
DSR 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete (110 mm )

12

-

268.68

... More
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.

-

-

-

... More
Bricks (70P+2k=72KM.)

6.09

-

2703.8

... More
Local Sand (10 KM.)

7.51

-

262.6

... More
Coarse Sand (30 KM.)

5.8

-

521.8

... More
Stone Chips (25) km

3.69

-

457

... More
Cement (10KM.)

1.84

-

360

... More
Steel ( 10 KM.)

0.11

-

360

... More
SOR PHED (page no 56 M 1038) DT: Basic rate for 125/115 mm dia drilled Tube Well for drilling in all kinda of Soil and rock for installation o hand pump with DI rings all complete including supplyin all materials, labours , tools drilling rigs air compressor and equipments s well as fuel li\ubricant for making 125/115 mm dia boring etc and cost of transporting rig machine and other vechile up to site of work including contrctor profit & OH chares as per specification and directtion of Engineer Incharge(basic rate)

-

-

-

... More
Drilling upto 30 M depth below G.L in Rular area

30

-

473.55

... More
Drilling beyond 31 mtr upto 55 mtr below GL in Rural area

30

-

509.96

... More
SOR PHED (page no 63 M 1041) Supplying all materials labours equipments for lowering 125 mm dia blue UPVC Casing Pipe as casing for protecting the sides from falling during the process of drilling all complete including carrriage of materials to work site (Basic Rate)

30

-

12.99

... More
S/M/L for F/f wire mesh pipe

1

-

52.8

... More
Land Development ( with Retaining wall)

-

-

-

... More
5.1.1 Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.

25.2

-

139.58

... More
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)

25.2

-

14.26

... More
5.1.8 Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed with earth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I ( Mode of measurement compacted volume)

128

-

118.49

... More
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)

2.25

-

415.58

... More
5.2.2 Providing designation 75A brick work in CM (1:4) in Foundation and plinth with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

9.25

-

5262.05

... More
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I

15

-

329.83

... More
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)

1.25

-

4492.36

... More
5.7.1 Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

90

-

169.18

... More
5.7.11 Providing 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as per building specification and direction of E/I.

90

-

51.66

... More
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.

-

-

-

... More
Bricks (70P+2k=72KM.)

4.24

-

2703.8

... More
Coarse Sand (30 KM.)

6.67

-

521.8

... More
Cement (10.0KM.)

1.55

-

360

... More
Add 12% GST

1

-

2650990.74

... More
Add 1% Lebour Cess

1

-

247425.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.