Food Corporation Of India Tender
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.
Costs
EMD
₹ 22,260Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Armo Electrical Works At Fsd Gaya For Fy 2022-23.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_FCI_739801_1Bid Award Id
ViewTender No
07/EM/22-23Tender Authority
Food Corporation Of India ViewPurchaser Address
-Website
http://http://fci.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
(a) upto 35 Sq.mm (Clamped with 1 mm thick saddle)
107
-
-
(b) Above 95 sq. mm and upto 185 sq. mm (Clamped with 25/40X3 mm MS flat clamp)
13
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
(a) Upto 35 sq. Mm
3
-
-
(b) Above 95 sq. mm and upto 185 sq. mm
18
-
-
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
(a) Upto 35 sq. Mm
40
-
-
(b) Above 95 sq. mm and upto 185 sq. mm
69
-
-
Supplying and fixing of light class G.l. pipe of 100 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required.
2
-
-
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required
(a) 100 mm dia
12
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
(a) 2 X 10 sq. mm (19mm)
14
-
-
(b) 3.5 X 25 sq. mm (28 mm)
2
-
-
(c) 3.5 X 120 Sq.mm (45 mm)
4
-
-
Supplying and fixing of Switch Disconnector Fuse unit of 320 A (Bolted Type: including 4 fuses) in Sheet Steel Encl. and giving connections on the wall surface/ panel etc, at site of work as required.
1
-
-
Supplying and fixing of Switch Disconnector Fuse unit of 100 A (Bolted Type: including 4 fuses) in Sheet Steel Encl. and giving connections on the wall surface/ panel etc, at site of work as required.
1
-
-
Supplying and fixing of 3 phase (RYBN), 315 A, 4 way, wall mounted aluminium BusBar chamber in sheet steel enclosure etc, at site of work as required.
1
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
(a) 4 way (4 + 12), Double door
1
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)
(a) 4 way (4 + 12), Double door
4
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) Single pole
32
-
-
(b) Single pole and neutral
14
-
-
(c) Triple Pole
4
-
-
(d) Triple pole and neutral
5
-
-
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) 100 A
1
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recess
along with 25/32 A 240 V "C" curve DP MCB complete with
connections, testing and commissioning etc. as required
1
-
-
Supplying and drawing following sizes of HRFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
4 x 10 sq. Mm
85
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
190
-
-
(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
75
-
-
(c) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
155
-
-
(d) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
60
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
82
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
(a) 6 Module (200mmX75mm)
3
-
-
(b) 12 Module (200mmX150mm)
21
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
(a) 5/6 A switch
87
-
-
(b) 15/16 A switch
3
-
-
(c) 3 pin 5/6 A socket outlet
87
-
-
(d) 6 pin 15/16 A socket outlet
3
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
10
-
-
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2
-
-
Supply of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type(not compact type) luminaire suitable for single T8 LED Tube etc.at the site of work.
59
-
-
Supplying of 9 watt LED BULB with efficacy min of 100 lumens/W and Colour Temperature- 6500K etc at the site of work.
2
-
-
Supplying, installation, Testing and commissioning of 40W LED Street light fitting made up of pressure die cast alluminium housing with IP 66,IK 07,LEDs with lumen efficacy of 140 lm/W, System efficacy of 110 lm/W,colour temp 6500 K,THD( %) 10 and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required.
7
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 Cum/min, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
16
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
59
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia
including accessories, and providing masonry enclosure with
cover plate having locking arrangement and watering pipe etc.
with charcoal/ coke and salt as required.
2
-
-
Providing and laying earth connection from earth electrode
with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth
electrode including connection with G.I. thimble excavation and
re-filling as required.
9
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess
for loop earthing as required
10
-
-
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
4
-
-
Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV/LED Street Light fitting on pole / wall / structure including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint as required.
7
-
-
Supplying and fixing of Hot pressed moulded SMC Junction box of size 230mm x 170mm x 105mm with 6A SP MCB, 2/4 way strip connector etc. as required at the site of work.
7
-
-
Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required.
14
-
-
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
12
-
-
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.
(a) 20 mm
100
-
-
(b) 25 mm
285
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
existing surface/ recessed Steel/ PVC conduit as required.
(a) 1 run of cable
100
-
-
2 run of cable
200
-
-
Supplying and fixing of 1 or 2 module, GI box in recess/surface alongwith modular base & cover plate including RJ45 socket oulet etc. as required at site of work.
21
-
-
Disposal of Dismantled Box Type conventional light fittings
15
-
-
Disposal of Dismantled Iron Scraps (MS Conduits, Switch Boards, DB's etc)
200
-
-
Disposal of Dismantled Aluminium Scraps (Wires etc)
30
-
-
Evaluation Notes How It Works ?