Public Works Building And NH Department Tender

... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Building And NH Department - PWDBNH Tender

Civil And Construction
Eprocure
Opening Date27 Dec 2018
Closing Date18 Jan 2019
Tender Amount₹ 34,50,75,451 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1) C) UNIFORM PILE (II) Concrete Grade M25 iv) Pile dia 450 mm

13905

-

-

... More
Extra for using admixture & plasticiser (b) RCC grade M25 v) Pile Dia 450 mm

13905

-

-

... More
Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement (iv) 450 mm dia

13905

-

-

... More
Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) (A) TMT bar made of Primary producer (From Primary producer)

2775

-

-

... More
Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)

102

-

-

... More
Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)

136

-

-

... More
Demolishing R.C.C./ P.C.C. pile head of different diameters carefully without disturbing the remaining portion of the pile including opening out of the pile head to be demolished by excavating the earth upto required depth and clearing the debris as directed.

25

-

-

... More
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume

430

-

-

... More
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick

3140

-

-

... More
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.

485

-

-

... More
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. c) M25 grade concrete

5122

-

-

... More
(B) In super structure from plinth level up to 1st floor level. i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. c) M25 grade concrete

1200

-

-

... More
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. P) Using admixture, plasticiser etc c) M25 grade concrete

2100

-

-

... More
iii) Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. N) Without using admixture, plasticiser c) M25 grade concrete

150

-

-

... More
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.

2050

-

-

... More
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank

2270

-

-

... More
Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank

1910

-

-

... More
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face

6190

-

-

... More
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.

11980

-

-

... More
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.

9715

-

-

... More
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.

2100

-

-

... More
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.

570

-

-

... More
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.2.1 .

17920

-

-

... More
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.

3995

-

-

... More
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.

135

-

-

... More
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)

1890

-

-

... More
200mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement morter of proportion 1: 5 including racking out joints and curing complete as directed in structure (protruding rod is to be provided at every 3 course interval and will be measured and paid separately) (b) In Super structure above plinth level upto 1st floor level

454

-

-

... More
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure (protruding rod is to be provided at every 3 course interval and will be measured and paid separately) (a) In Super structure above plinth level up to 1st floor level

4200

-

-

... More
(b) In Super structure above 1st floor level upto 2nd floor level

3250

-

-

... More
( c) In Super structure above 2nd floor level upto 3rd Floor level

2800

-

-

... More
( c) In Super structure above Terrace

850

-

-

... More
Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.

280

-

-

... More
Extra cost for lifting of brickbats and sand for filling of sunk floor for each subsequent floors above the ground floor as directed and specified.

204

-

-

... More
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4

9550

-

-

... More
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4

15775

-

-

... More
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4

4960

-

-

... More
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.

3850

-

-

... More
Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. a) On Single coat plaster

5750

-

-

... More
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. b) On two coat plaster

2480

-

-

... More
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level(fron 1st floor to 2nd floor level) including curing complete as directed. b) On two coat plaster

3790

-

-

... More
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars

9810

-

-

... More
Extra over item 18.1.1(a) for each subsequent floor or part thereof 1st floor to 2nd floor level.

3960

-

-

... More
Steel work welded in built up sections, framed work including cutting, hoisting and fixing in positions and applying priming coat of red-lead paint including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. a) In beams and joists with connecting plates/ angled cleat.

370

-

-

... More
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.

82

-

-

... More
Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire length and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters.

120

-

-

... More
Providing and fixing Stainless Steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of Stainless Steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)

360

-

-

... More
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) - Thickness = 1.5 mm thick (i) Thickness = 1.5 mm thick

43520

-

-

... More
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.

43520

-

-

... More
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth - Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)

38180

-

-

... More
Extra for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) - Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)

38180

-

-

... More
Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.

165

-

-

... More
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak"/Asian Paints/ Berger paints brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.

5340

-

-

... More
Extra over item no.13.5.2 above for every subsequent coat of acrylic emulsion exterior coatings of Unicem 'Rakshak' brand of required shade.

5740

-

-

... More
Polishing with french sprit polishing on new wood and wood based surfaces to give an even surface including cleaning the surface of all dirt, dust sand papered smooth and including a coat of wood filter

75

-

-

... More
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wood

5.25

-

-

... More
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core. (iii) 30 mm thick .

756

-

-

... More
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a)2 Track sliding window (i)6mm clear glass

520

-

-

... More
(ii)5mm frosted glass

49

-

-

... More
(b)3 Track sliding window (i)6mm clear glass

145

-

-

... More
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). a)Side hung and Top hung windows and ventilators (i)6mm clear glass

445

-

-

... More
(ii)5mm frosted glass

32

-

-

... More
(b)Fixed windows and ventilators (i)6mm clear glass

38

-

-

... More
(ii)5mm frosted glass

45

-

-

... More
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (i)6mm clear glass

30

-

-

... More
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete etc complete as specified and directed by the department at all levels. (a) with 12 mm thick toughened glass

28

-

-

... More
Providing , fabrication and fixing of structural glazing made out of Anodised aluminium mother frame 6 nos 1.2m each @ 1.819 Kg/m and subframe of 16 nos 0.60 m each @ 0.31 Kg/m of Jindal or equivalent and 5 mm reflective glass of approved shade. The glass to be pasted using structural silicon (DC 995) and weatherseal silicon to be used (DC 789), the structure complete with all accessories as and where necessary.

350

-

-

... More
Supplying,fitting and fixing of Automatic sliding door and operator, modular design including internal cover with operator dimensions (H X T) not exceeding 120mm x 175mm and of length required to suit the opening size given below: Clear opening of size 2400mm X 2400mm: compact linear sliding door automatic, with self cleaning rollers, TUV type tested as per DIN 18650.The Automatic sliding door consists of 16 bit Microprocessor Control unit, monitoring of closing force, automatic reverse on contact with obstruction, operator commissioning without any additional instrumentation and self-teaching. Operating Modes: Continuous open, automatic operation, closing time, night lock, multi-sensor detector(radar motion detector with direction detecion and self-monitoring, double 3D safeguard light curtain (light barrier) for convenient safeguarding of the opening width) with Electro magnetic locking, integrated in the drive unit, with manual emergency unlocking of GODREJ/GEZE make.The operator will be provided with short circuit proof power supply unit 220 / 240 V, 50 / 60 hz . (d) door Automatic ST20 D

1

-

-

... More
Providing Ceramic Tiles ON FLOORS of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). Normal range Somany/ Orient/Nitco /Asian Make Of size 300mmx300mm and above

590

-

-

... More
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). c) Delux range Somany/ Orient/Nitco/Make iv) Of size 300mmx600mm and above

1155

-

-

... More
v) Of size 300mmx900mm and above

900

-

-

... More
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Nitco /Quotone/ Make ii) Of size 600mmx600mm and above

4050

-

-

... More
b) Executive range (800mmx800mm) Somany/Nitco/Orient /Quotone made

1150

-

-

... More
c) Delux range Somany/ Orient/Nitco /Quotone/Jhonson Make i) Of size 1000mmx1000mm and above

422

-

-

... More
Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (b) MULTIWYN TILES Legato, Ribbera, Matrix, Esquire, Enigma, Flora, Little Flora, Nirvana, Purl, Contoura, Cobble, Canaletta, Nexus, Koral

1600

-

-

... More
Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (2) 600mm x 900mm and above

2732

-

-

... More
Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. (2) 600mm x 900mm and above

344

-

-

... More
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.

72

-

-

... More
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (iii) Deluxe Quality (i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)

80

-

-

... More
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. VITRIFIED i) Nitco made a). Imperia Series- Gres Tiles

875

-

-

... More
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) b)Tower bolts i) 300mm x 12mm

8

-

-

... More
m) Mortice lock vertical type iii) 100mm(Godrej with handle (6 lever)

41

-

-

... More
iv) Aldrop with In built Lock-6 lever kadi tala(Godrej Make)

254

-

-

... More
t) Door stopper with rubber stopper

207

-

-

... More
Supplying, fitting, fixing Stainless Steel fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ) b) Tower Bolt i) 300mm x 10mm

515

-

-

... More
c) Door Handle iii) 150mm

547

-

-

... More
Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. A) Godrej c) Heavy Duty Door Closer( size 180 mm x 65mm x 64mm)

97

-

-

... More
e) Concealed Door Closer ( 230mm x 76.5mm x 30.5mm)

2

-

-

... More
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I . Plain grill (c) Fixed to Brickwork/P.C.C/R.C.C.

4400

-

-

... More
Preparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.

3300

-

-

... More
Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF mixed with cement in the ratio 1:2 as final coat. (A) Using Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)

3300

-

-

... More
Supplying, providing, mixing and laying over waterproofing layers/ coatings with concrete screed of average 30mm thick or as per drawings/ requirements in proportion 1:2:4 (1cement : 2fine aggregate : 4coarse aggregate) (by volume) with 10mm and down well graded aggregates and admixed with a normal plasticizer like Master Plast PL-1 of Choksey Chemicals /Dr. Sealkit Normal Plast (Asian Chemicals)/Rheomac 707 of BASF @ 0.3% by weight of cement and thereafter scoring the top surface of the concrete screed @ 200mm c/c as specified and directed by the Department.

85

-

-

... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 - 1 cement: 2 coarse sand: 4 graded stone agg. 20 mm nominal size)

285

-

-

... More
Providing and applying over sunken slab etc., two coats of waterproofing slurry prepared with neat cement, water and modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/ RHEOMIX 141 by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.

985

-

-

... More
Providing and laying Polymeric waterproofing membrane sheets Hyperplas Standard of IWL India Ltd. @3kg/sq.m. having 90micron HMHDPE film as centre core with polymeric mix of softening point 118oC and penetration of 25-40 covered on both side and laminated with 20micron HMHDPE, layed over first coat of water based emulsion primer @ 100gms/sq.m. and using hot blown bitumen 90/15 or 85/25 @ 1.2kg/sq.m. followed by repeatation of the bitumen coat and then final coat of bituminous aluminium @ 100gms/sq.m. complete as specified and directed by the Department followed by :

225

-

-

... More
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.

2600

-

-

... More
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. b) with aqueous emulsion having concentration 1:499 with Premise 350 SC (Imidachloprid 30.5% SC) and water, i.e. 0.07% solution.

3900

-

-

... More
Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. b) with aqueous emulsion having concentration 1:499 with Premise 350 SC (Imidachloprid 30.5% SC) and water, i.e. 0.07% solution.

1200

-

-

... More
Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.) (b)Using Grading II material

435

-

-

... More
Providing, laying, sopreading and compacting stione aggregates of specific size to water bound mecadam specification including spreading in uniform thickness, hand-packing, rolling with vibratoy roller8-10 tonnes in stages to proper grade and camber, applying and brooming Type -A (13.2 mm agg.) screening/binding material to filled up the interstices of coarse aggregate watering and compacting to the reqd. density( with all initial lead of 5.0 Km) By Manual means Grading II using Screening Type B(11.2mm agg)

220

-

-

... More
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 40 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.

2900

-

-

... More
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.

910

-

-

... More
Collection of sample from field and testing in laboratory/field as per relevant I.S. codes of practice and preparation and submission of of the reports to the concerned authority in proper format with specified no. of copies (minimum 5 copies) B. Concrete (i) Compressive strength(including moulding &curing)

30

-

-

... More
(ii) Compressive strength(excluding moulding)

30

-

-

... More
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling sections of 0.55 mm thk with knurled web of 51.5 mm and two equal flanges of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips perpendicular to the intermediate channel at 457mm c/c and 12.5 mm thk gypboard fixed to the ceiling sections with 25 mm drywall screws at 230mm c/c. the boards joints are finished with joint paper and two coats of drywall topcoat at all levels including cutting for providing and fixing light fixures whwre ever necessary. and as p[er design.

350

-

-

... More
Providing and fixing Mineral Fiber Acoustic Ceiling Tiles in 600mm x 600mm of 13mm/15mm thickness to be placed in Grid Suspended Ceiling Grid 2430 System consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. Main Runner shall be placed along the shorter dimension of the area to be covered. The distance between the two Main Runners to be maintained at 1200mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm.E-Grid of module size 600mm x 600mm shall be supported by 4/6 mm dia G.I. wire from purlins/soffit Mineral Fiber Acoustic Ceiling Tiles of Everest Industries Limited should be placed in the E-Grid module to form a False Ceiling including the cuttings complete as directed. A) Using 13mm thick ceiling tiles of Armstrong make

133

-

-

... More
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint)97 mm metal stud partition (single layer) including one layer of 12.5 mm thk gypsum board fixed with 25mm drywall screw at 300 mm c/c to one side of 75 mm studs (0.55 mm thk having one flange of 34mm and another of 36 mm made og GI steel with joints staggerred with jointing the tapered and square edges of gypboard with joint tape to have a flushed look and two coats of drywall coats as per design and as directed.

60

-

-

... More
Supply fitting and fixing of Mac/Vista or equivalent make vertical blinds with necessary hardwares like runner channels etc with 100 mm width fabric blinds and as per choice and directed.

150

-

-

... More
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii)300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.

320

-

-

... More
Providing drain with reinforced cement concrete (1:3:6) 15 cm thick sides 15 cm thick bed over brick flat soling finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i) 450 mm wide and average 450 mm deep with bed slope 1 in 300 with initial depth of 300 mm.

650

-

-

... More
Providing and fixing of self-supporting rectangular pure terracotta(non ceramic/non porcealin) louvers/baguettes of 50mm x 100mm size of PARA GRID make "Terrakot" baguettes with an average length of 600mm to 980 mm fixed at intervals of 250 mm c/c with two internal tubes. The sub frame shal be powder coated/anodised 6063 grade aluminium sections with size of 50mm x 75 mm and fixed at interval of 1000 mm c/c. The sunscreens are to be fixed without any intermediate joints and as per directions Architect. Finish and color of louvers &aluminium elements would be as per drawing/approval

180

-

-

... More
Providing and fixing "TERRAKOT" PARA GRID make terracotta clay tile cladding of dimension modules of 300*900/1200*18 mm with modulus of rupture not less than 20.2 N/mm2 as per ISO 10545-3:1995, breaking strength of 4.1 N as per ISO 10545-4:1995, water absorption to be between 4-6% conforming to ISO 10545-3:1995 ,thermal shock resistance as per ISO 10545-9:2013 and resistance to stains having value 4 as per ISO 10545-14:1995.The tiles should have passed the Thermal Shock resistance test as per ISO 10545-13:1995. The installation of TERRAKOT panels to be done by using standard framing design bearing a " U" channel on a "L/T/Y "shaped Aluminium profile and fixed to the wall using Aluminium/MS brackets.The tiles to be held by Aluminium/SS clips with add on of a flat plate between the clip and the tiles.The top and the bottom copings to be done using tiles or metal sheets as per architect recommendations.The corners should be done using a 45 degree mitred cut or a butt joint as per shop drawings approved by the architects.Tiles made in EU factory. The modules are to be made on the basis of the width of the tile restricting to a minimum of 600 mm and maximum of 1200 mm. The grid has to be initially designed considering horizontal and vertical lines drawn as reference after checking the levels at site.A plastered wall with minimum undulation is desired.The brackets are to be fixed as staggered and designed to adjust the profiles to match any unevenness.The profile would be screwed on to brackets and the brackets would be fixed using Hilti/Fischer/Arrow anchors.The SS/Aluminium clips would be screwed using Hilti Self taping screws and the tiles would be fixed on to it.The facade should be checked from time to time to ensure that the tiles are fixed properly.

95

-

-

... More
Providing modified clay cladding of approved quality, size, shape and thickness not less than 3 mm on external walls over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of stone, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). PHOMI make MCM Travertine 031Y of size 1200 x 600

425

-

-

... More
Supplying, fabrication and fitting of stainless steel railing with 13.5 mm thick eva laminated glass as per approved design with SS 304 grade stainless steel post and top rail of 50 mm dia complete as directed.

108

-

-

... More
Providing, supplying and fixing of Frameless Single leaf/double Swing Glass Door of Dorma/ Ozone or equivalent make in glazing using 12mm thick toughened glass of Saint Gobain / or approved equivalent with die cast patch fitting with stainless steel cover including fixing of patch fittings, floor springs, locks, handles etc. using the hardware items as detailed, complete in all respects as per detailed drawings, specifications and direction of Engineer in charge. Single Leaf Door with Dorma or Equivalent Hardware’s as specified:- Swing Glass Door which includes each of Top Pivot PT 24, Bottom Patch PT 10, Top Patch PT 20, Floor Lock US 10, Strike Plate , Floor Spring BTS 75v, with pair of TGDIH SS Pull Handle 25 mm dia x 450 mm long and other accessories for self closing feature as per detailed drawings. a) Single/double door with (1X2.4M)

9

-

-

... More
Providing fiting and fixing of Wood Plastic Composite (WPC) door frames of natural and brown colour of 100mm x 65 mm section and density not less than 900 kg/ cum, single rebated rectangular section including joining of top mullion and vertical members with mitred joint and fixing to the wall jamb with MS holdfasts/ Metal Screw and metal rawl plug.

1150

-

-

... More
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling sections of 0.55 mm thk with knurled web of 51.5 mm and two equal flanges of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips perpendicular to the intermediate channel at 457mm c/c and 12.5 mm thk Calcium Silicate HILUX Board fixed to the ceiling sections with 25 mm drywall screws at 230mm c/c. the boards joints are finished with joint paper and two coats of drywall topcoat at all levels including cutting for providing and fixing light fixures whwre ever necessary. and as p[er design.

109

-

-

... More
Providing fitting and fixing of 1200x300 Jhonson make Endura stepping stone (15mm thick) full body vitrified tiles with double nosing and self embrossed tread lines, skid resistant, Lowest water absorption of 0.05 % along with enhanced stain resistance and Highest abrasion resistance of 144 mm3, complete in all levels as directed and as per design.

267

-

-

... More
Providing fitting and fixing of 1200x600 Jhonson make endura meteor riser/landing (15 mm thick) full body vitrified tiles with double nosing and self embrossed tread lines, skid resistant, Lowest water absorption of 0.05 % along with enhanced stain resistance and Highest abrasion resistance of 144 mm3, complete in all levels as directed and as per design.

89

-

-

... More
Providing fitting and fixing of 6.5 mm thick Armstrong make Athleta sports flooring (Roll) with PUR bcoated top layer and reinforced by fibre glass backing including jointing of floor matt by heat weilding to give a seamless floor complete in all levels as per approved shade and as directed. The flooring will have a fire resistance of class B1 and sound Insulation 21B.

688

-

-

... More
Providing and fixing at all heights and depths 75 MM thick DURABOARD HD-100 as per BIS-1838-Part-3 , pre-moulded compressible filler board in black colour manufactured by the The Supreme Industries Ltd. conforming to MORTH Specification (Clause 1015), having minimum density 95kg./ cum, Non staning with less than 1% water absorption and compression recovery of 93% minimum as per manufactured specification including cost and conveyance of all materials, tutting and placing to the required size, labour charges, sundries, wastage etc. at all levels complete as per drawings and as direction and satisfaction of Engineer-in-charge. DURAboard HD 100 will become one side of the shuttering while the expansion joint is being created.

125

-

-

... More
Providing, laying and fixing (50x20) polysulphide sealants as per IS 12118 OR BS 4254 at expansion jts. at ends as directed by Engineer –in-charge as per manufacturer's specification at all heights and depths including all to make the job complete.

410

-

-

... More
Supply, installation and commissioning of 10 passenger (680 Kg) lift with speed of 1 mps and 3 stop with all openings on one side with following specifications: ACD3-MR controller, VF Regenerative (Closed Loop) Drive, PM Gearless (Located above shaft) , TRACTION MEDIA of Flat Coated Steel Belt, car finish with Rear Mid Panel = Stainless Steel #4(Hairline), Rear Corner Panels = Stainless Steel #4(Hairline) Side Panels = Stainless Steel #4(Hairline), Front Panels = Stainless Steel #4(Hairline) including Stainless Steel #4(Hairline) false ceiling/ car door/landing door and Stainless Steel Mirror Finish Handrails on rear car panels and Anti-nuisance Car Call Protection Independent Service (for Duplex only), Overload Device, Nudging, Emergency, Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut Off including Monochrome LCD-Blue Background & White font car position indicator with Automatic Rescue operation, Intercom, including 12 months of maintainance. OTIS make.

2

-

-

... More
Supply and Installation of Rheinzink Cladding system which includes 4mm Zinc Composite Panel of Rheinzink.The Zinc must be of German origin and the composite panel consisting of 0.5 mm Pre Patina Zinc.The zinc shall not have any colour pigmentations and be completely natural. The composite panels are to be fixed on Aluminium angles with vertical and horizontal support with Aluminium runner, Screws, brackets. The joints are to be sealed with weather silicon preferrably of make Dow Corning 789/BECKER WATHER SILICON/GE or equivalent. The system shall be designed to withstand a wind pressure not less than as specified in wind pressure Zoning details to be provided by consultant.Shop drawings will be provided for approval before implementation There will be no extra claims shall be entertained at any stage for aluminium profile wall thickness and size dimensions.The extruded Aluminium sub frames will have a thickness shall not less than 1.8/2 mm & shall be confirming to Alloy 6063-T5/T6 of make Jindal. SS304 screws to be used and all nut-bolts, anchors shall be only SS 316 Hilti /Fischer make.

510

-

-

... More
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated Sheet Cover ,ceiling rose etc. complete Short point up to 3.00 metre. length.

1202

-

-

... More
Medium point up to 6.00 metre. Length.

724

-

-

... More
Long point up to 10.00 metre. Length.

556

-

-

... More
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Short point up to 3.00 metre. length.

212

-

-

... More
Medium point up to 6.00 metre. Length.

147

-

-

... More
Long point up to 10.00 metre. Length.

155

-

-

... More
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Short point up to 3.00 metre. length.

60

-

-

... More
Medium point up to 6.00 metre. Length.

55

-

-

... More
Long point up to 10.00 metre. Length.

44

-

-

... More
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Extra long point up to 15.00 metre. length.

29

-

-

... More
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 2 mm thick conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 2.5 sq. mm. + Earth continuity with 1x1.5 sq. mm. in 20 mm. Dia. 2mm Thick/ Heavy Rigid PVC IS: 9537 Part - III Conduit.

4555

-

-

... More
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.

300

-

-

... More
With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.

1010

-

-

... More
With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.

1006

-

-

... More
Wiring for twin control light point with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 amp flush type 2 way switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Long point up to 10.00 metre. Length.

54

-

-

... More
Supplying and fixing 18 S.W.G sheet steel metal boxes of the following sizes in surface/ recessed Wiring system with suitable size of 3 mm thickness phenolic laminated sheet cover on the front face of the boxes including painting etc. as required and specified by the department. 100 mm x 100 mm x 60 mm deep (Nominal size

114

-

-

... More
100 mm x 150 mm x 60 mm deep (Nominal size

149

-

-

... More
100 mm x 175 mm x 60 mm deep (Nominal size

115

-

-

... More
200 mm x 150 mm x 60 mm deep (Nominal size

41

-

-

... More
200 mm x 200 mm x 60 mm deep (Nominal size

65

-

-

... More
200 mm x 250 mm x 60 mm deep (Nominal size

25

-

-

... More
200 mm x 300 mm x 60 mm deep (Nominal size

73

-

-

... More
250 mm x 300 mm x 60 mm deep (Nominal size

44

-

-

... More
250 mm x 350 mm x 60 mm deep (Nominal size

72

-

-

... More
200 mm x 350 mm x 60 mm deep (Nominal size

53

-

-

... More
Supplying and fixing of 3 plate Ceiling Rose (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing block including connection as approved by the Deptt.)complete as required

1613

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

2032

-

-

... More
Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 20A Capacity. (ABB, Schneider MG, legrand, Hager make)

18

-

-

... More
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof reversible Double door IP-43 double door surface mounting horizontal TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 8 way TPN (8+24) double door

7

-

-

... More
12 way TPN (8+36) double door

65

-

-

... More
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 63A

72

-

-

... More
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 40A

186

-

-

... More
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)

526

-

-

... More
Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 100 watt electronic modular 4 step speed control 2 - module type

526

-

-

... More
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Ventilator DX 250 mm sweep Louver type (ORIENT make), Brisk Air 250 mm sweep Louver type/ Trans Air 150 mm sweep (Crompton make), Ventil Air DX 150 mm sweep Louver type (Havells make)

76

-

-

... More
Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the Deptt.)as required.

24

-

-

... More
Installation, testing and commissioning of ceiling fan including the regulator /down rod of standard size (Up to 300 mm ) length including connection as approved by the Deptt.)as required.

526

-

-

... More
Supplying extra down rod of 10 cm long G.I. pipe 20 mm dia heavy gauge including painting etc. as required

526

-

-

... More
Installation of Exhaust fan up to 450 mm sweep in the existing opening including making the hole to suit the size of the above fan, making good the damages, testing, commissioning etc. as required complete

76

-

-

... More
Extra for fixing the Louvers/Shutters complete with frame for exhaust fans of all sizes

76

-

-

... More
Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.

526

-

-

... More
Supply including fitting and fixing of 11 KV ( SCREENED XLPE cables heat shrink type three core HT cable indoor termination Kits RAYCHEM RPG including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 120.00 to 185.00 Sq.mm., three core cable.

4

-

-

... More
Supply including fitting and fixing of 11 KV ( SCREENED XLPE cables heat shrink type three core HT cable straight through jointing kits RAYCHEM RPG including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 120.00 to 185.00 Sq.mm., three core cable.

4

-

-

... More
Supplying, installation of GI PERFORATED cable tray on wall or from ceiling including necessary channel, nuts and bolts, washer etc. as required as directed and specified by the department. (LEGRAND/ AKG /STRUTFAST make). Size of Tray 50

6

-

-

... More
Size of Tray 76

12

-

-

... More
Size of Tray 101

40

-

-

... More
Size of Tray 152

75

-

-

... More
Size of Tray 203

25

-

-

... More
Size of Tray 228

95

-

-

... More
Size of Tray 304

120

-

-

... More
Bend 50

2

-

-

... More
Bend 76

4

-

-

... More
Bend 101

6

-

-

... More
Bend 152

9

-

-

... More
Bend 203

6

-

-

... More
Bend 228

8

-

-

... More
Bend 304

20

-

-

... More
Inter/Exter Bend 50

2

-

-

... More
Inter/Exter Bend 76

4

-

-

... More
Inter/Exter Bend 101

6

-

-

... More
Inter/Exter Bend152

9

-

-

... More
Inter/Exter Bend 203

6

-

-

... More
Inter/Exter Bend 228

8

-

-

... More
Inter/Exter Bend304

20

-

-

... More
Tee 50

2

-

-

... More
Tee 76

4

-

-

... More
Tee 101

3

-

-

... More
Tee 152

9

-

-

... More
Tee 203

6

-

-

... More
Tee 228

6

-

-

... More
Tee 304

12

-

-

... More
Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixtures of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 300 mm dia

140

-

-

... More
200 mm dia

78

-

-

... More
150 mm dia

30

-

-

... More
Preparing the man holes of followign sizes for 33 kv & LT cables as per the route provided in the drawing and as per the site conditions in guidance of the site incharge at sit 800 x 800 x 800 size

18

-

-

... More
1200 x 1200 x 1200 mm size

7

-

-

... More
Supplying and fixing of Jaquar make 40W LED TUBE LIGHT CAT no LUNIOX220 XC fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required.

160

-

-

... More
40 W, BBG 150/151 LED 50/ NW PSU 220-240 V IP 65. or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (Jaquar oe equivalent make ).

50

-

-

... More
Supplying and fixing of Jaquar(CAT NO LGLZPCX022XC) or equivalent LED strip batten light fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. LED Strip Batten,22W

750

-

-

... More
Supplying and fixing of Jaquar or equivalent recessed mounted LED downlighter with aluminium die cast housing fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. LED 9W (CAT NO NERO Square LNRO01S009XC)

25

-

-

... More
LED 12W (CAT NO NERO Square LNRO01S012XC)

35

-

-

... More
LED 18W (CAT NO NERO Square LNRO01S018XC)

50

-

-

... More
Supplying and fixing of Jaquar or equivalent recessed mounted 36W 2' x 2' 125Lm/W LED panel downlighter withwhite powder coated CRCA housing with full mounted acrylic diffuser fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required.

50

-

-

... More
Supplying and fixing of Jaquar or equivalent LED wall light fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. LED Bulk Head 10W

18

-

-

... More
Supplying with fitting & fixing of the following road lighting luminaries complete in the existing pole with high power LED and extendable up to with unique peanut lens to ensure uniform distribution including making necessary connection as approved by the Deptt.)with 2× 2.50 sq.mm F.R. multistrand and P.V.C. insulated single core copper cable as specified and directed by the department. Supplying and fixing of Jaquar or equivalent Philips/ Wipro LED outdoor light fittings complete with all accessories including connection cable, as approved by the Deptt.s etc. as required. LED Bollard 4W

35

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 250 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 35KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 250 Amp 35KA 4P MCCB Current Transformer- Ratio: 250/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 350A. OUTGOING 1 no. 125A 25 KA FP MCCB (1ST FLOOR, FLOOR PANEL) 1 no. 125A 25 KA FP MCCB (2ND FLOOR, FLOOR PANEL) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
ACADEMIC BLOCK-FLOOR PANEL-FIRST FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ." (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from ACADEMIC BLOCK-MAIN FLOOR PANEL-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 125 Amp 25KA 4P MCCB Current Transformer- Ratio: 125/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
ACADEMIC BLOCK-FLOOR PANEL-SECOND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ." (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from ACADEMIC BLOCK-MAIN FLOOR PANEL-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 125 Amp 25KA 4P MCCB Current Transformer- Ratio: 125/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
BOY'S HOSTEL-MAIN FLOOR PANEL-01-GROUND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ." (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 160 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 35KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 160 Amp 35KA 4P MCCB Current Transformer- Ratio: 160/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 250 A. OUTGOING 1 no. 100A 25 KA FP MCCB (1ST FLOOR, FLOOR PANEL) 1 no. 125A 25 KA FP MCCB (2ND FLOOR, FLOOR PANEL) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
BOY'S HOSTEL- FLOOR PANEL-01-FIRST FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from BOY'S HOSTEL-MAIN FLOOR PANEL-01-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 125 Amp 25KA 4P MCCB Current Transformer- Ratio: 125/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
BOY'S HOSTEL- FLOOR PANEL-01-SECOND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from BOY'S HOSTEL-MAIN FLOOR PANEL-01-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 100 Amp 25KA 4P MCCB Current Transformer- Ratio: 100/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
BOY'S HOSTEL-MAIN FLOOR PANEL-02-GROUND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 160 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 35KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 160 Amp 35KA 4P MCCB Current Transformer- Ratio: 160/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 250 A. OUTGOING 1 no. 100A 25 KA FP MCCB (1ST FLOOR, FLOOR PANEL) 1 no. 125A 25 KA FP MCCB (2ND FLOOR, FLOOR PANEL) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
BOY'S HOSTEL- FLOOR PANEL-02-FIRST FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from BOY'S HOSTEL-MAIN FLOOR PANEL-02-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 125 Amp 25KA 4P MCCB Current Transformer- Ratio: 125/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
BOY'S HOSTEL- FLOOR PANEL-02-SECOND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from BOY'S HOSTEL-MAIN FLOOR PANEL-02-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 100 Amp 25KA 4P MCCB Current Transformer- Ratio: 100/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
GIRL'S HOSTEL-MAIN FLOOR PANEL-01-GROUND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 160 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 35KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 160 Amp 35KA 4P MCCB Current Transformer- Ratio: 160/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 250 A. OUTGOING 1 no. 100A 25 KA FP MCCB (1ST FLOOR, FLOOR PANEL) 1 no. 125A 25 KA FP MCCB (2ND FLOOR, FLOOR PANEL) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
GIRL'S HOSTEL- FLOOR PANEL-01-FIRST FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from GIRL'S HOSTEL-MAIN FLOOR PANEL-01-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 125 Amp 25KA 4P MCCB Current Transformer- Ratio: 125/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
GIRL'S HOSTEL- FLOOR PANEL-01-SECOND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from GIRL'S HOSTEL-MAIN FLOOR PANEL-01-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 100 Amp 25KA 4P MCCB Current Transformer- Ratio: 100/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
GIRL'S HOSTEL-MAIN FLOOR PANEL-02-GROUND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 160 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 35KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 160 Amp 35KA 4P MCCB Current Transformer- Ratio: 160/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 250 A. OUTGOING 1 no. 100A 25 KA FP MCCB (1ST FLOOR, FLOOR PANEL) 1 no. 125A 25 KA FP MCCB (2ND FLOOR, FLOOR PANEL) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
GIRL'S HOSTEL- FLOOR PANEL-02-FIRST FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from GIRL'S HOSTEL-MAIN FLOOR PANEL-02-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 125 Amp 25KA 4P MCCB Current Transformer- Ratio: 125/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
GIRL'S HOSTEL- FLOOR PANEL-02-SECOND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from GIRL'S HOSTEL-MAIN FLOOR PANEL-02-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 100 Amp 25KA 4P MCCB Current Transformer- Ratio: 100/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-02) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
MULTIPURPOSE HALL-MAIN FLOOR PANEL-GROUND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 250 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 35KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 250 Amp 35KA 4P MCCB Current Transformer- Ratio: 250/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 350 A. OUTGOING 1 no. 100A 25 KA FP MCCB (1ST FLOOR, FLOOR PANEL) 1 no. 125A 25 KA FP MCCB (2ND FLOOR, FLOOR PANEL) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, SPL LIGHT DB-01) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
MULTIPURPOSE HALL- FLOOR PANEL-FIRST FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from MULTIPURPOSE HALL-MAIN FLOOR PANEL-GROUND FLOOR having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 125 Amp 25KA 4P MCCB Current Transformer- Ratio: 125/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, POWER DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR, SPL LIGHT DB-01) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
WARDEN QUATER-FLOOR PANEL -GROUND FLOOR Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 100 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 100 Amp 25KA 4P MCCB Current Transformer- Ratio: 100/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 150 A. OUTGOING 1 no. 40 A 10 KA DP MCB (COMMON AREA GROUND FLOOR, LIGHT DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR FLATE-01,L+P DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR FLATE-02,L+P DB-02) 1 no. 63 A 10 KA 4P MCB (FIRST FLOOR FLATE-01,L+P DB-01) 1 no. 63 A 10 KA 4P MCB (FIRST FLOOR FLATE-02,L+P DB-02) 3 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
OPEN AIR THEATRE-FLOOR PANEL Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 100 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 160 Amp 25KA 4P MCCB Current Transformer- Ratio: 160/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR ,L+P DB-01) 1 no. 63 A 10 KA 4P MCB (SPARE) 1 no. 63 A 10 KA 4P MCB (SPARE) 1 no. 63 A 10 KA 4P MCB (SPARE) 1 no. 63 A 10 KA 4P MCB (SPARE) 1 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
KITCHEN & DINNING-FLOOR PANEL Design, manufacture, supply, installation, testing and commissioning of sheet steel cubicle type FLOOR Panel floor/wall mounted type fabricated from 14 SWG CRCA sheet, free standing, indoor duty, dust proof, vermin proof, front operated electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention in BOQ. (Under no case temperature of FLOOR PANEL shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). Degree of protection IP-42 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCB's. Colour: Siemens Gray Powder Coated or as per approved shade. INCOMER One Numbers 125 A 4P MCCB incomer breaker from MAIN LT PANEL having microprocessor based, over current, earth fault, short ckt. with relay, phase to neutral & neutral to earth spark gap surge suppresor for 25KA with fuses, 3 phase monitoring relay with phase sequence. This incomer shall have digital multifunction meter and RS 485 port with matching cast resin CT's, volt meter, voltmeter selector switch,ammeter, ammeter selector switch, indication lights for phases with MCB, ON /OFF /TRIP indication light for spring charge. Circuit Breaker Rating - 125 Amp 25KA 4P MCCB Current Transformer- Ratio: 125/5A CL:1 & 5P10, 15VA Relays- IDMT 2 O/C+1 E/F RELAY METERS- Digital Ammeter with selector switch Digital Voltmeter with selector switch Set of indication Lamp- Red-OFF Green-ON White-Trip Circuit Healthy Amber-Trip Condition Set of fine wiring, Ferrules & Fuses. Power Pack 230V AC/24V DC Supply BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 160 A. OUTGOING 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR ,L DB-01) 1 no. 63 A 10 KA 4P MCB (GROUND FLOOR ,P DB-01) 1 no. 63 A 10 KA 4P MCB (SPARE) 1 no. 63 A 10 KA 4P MCB (SPARE) 1 no. 63 A 10 KA 4P MCB (SPARE) 1 no. 63 A 10 KA 4P MCB (SPARE) Other items such as 1 set of control wiring 1 Set of designation plates All Items complete as above

1

-

-

... More
EXTERNAL LIGHTING FEEDER PILLAR- 01 & 02 Design, manufacture, supply, testing and commissioning of Panel fabricated out of 16 SWG CRCA sheet steel, IP 54, wall / floor mounting type with rain canopy The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect. INCOMER : 125 AMP FP MCCB 1 no. 125 A, 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's. BUS BAR TPN Aluminium bus bar with heat Shrink Sleeve rated for 150A. OUTGOING 12 nos 25 A DP MCB ON indication lamps with 3 nos 63A DP MCB astronimical time swtich for automaitc switching of landscape light fixtures at sun set and sun rise or twillight ( auto on/ auto off and auto mode)with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site. 12 nos 25A DP MCB (LIGHT CKT) Other items such as 1 Set of control wiring 1 Set of designation plates All Items complete as above All Items complete as above

2

-

-

... More
Providing fitting and fixing Vitreous china Dual Flush/ wall hang water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) ii) Hindware make a) White (vii) Wall mounted Closet Crystal (inclusive of seat cover and fittings) (Cat. No. 20047)

12

-

-

... More
Providing fitting and fixing Vitreous china Dual Flush / Floor Mounted Coupled / Extended water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) B) Hindware make a) White 1) Extended Type (vii) Studio (inclusive of seat cover and fittings) (Cat. No. 20058) (P Trap)

144

-

-

... More
Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (B) Hindware Make (i) Concealed Cistern 83mm with Prime flush plate 83mm

12

-

-

... More
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. B) Hindware make a) White (v)Senso Urinal (Cat. No.60018)

18

-

-

... More
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (B) Hindware Make (a) White (ii) Dyna (Cat. No.60010)

59

-

-

... More
Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. (ii) Hindware Make (a) White (ii) New Division Plate (Cat. No.61005)

77

-

-

... More
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Under Counter Basin (B) Hindware Make (a) White (i) Lara (Cat. No.10095)

132

-

-

... More
Basin (without pedestal) (B) Hindware Make (a) White (ii) Standard 630 x 450 (Cat. No.10001)

16

-

-

... More
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (A) Parryware Make (i) Single Bowl with Veg Bowl & Drain Board (400 x 200) Flat Edge- Glossy (Cat.No.C8545)

7

-

-

... More
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mm x 450mm

49

-

-

... More
Providing fitting and fixing Glass Shelf complete as directed and specified. Glass shelf with C.P. guard rail (iii) Jaquar make (a) Continental 550 mm long (Cat. No.ACN-1171N)

8

-

-

... More
Corner glass shelf with bracketsof Jaquar Make (a) Jaquar Make Continental (Cat.No.ACN-1173)

6

-

-

... More
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)

214

-

-

... More
Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1135N) (with glass bottle)

12

-

-

... More
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No. ACN-1101N)

58

-

-

... More
(ii) Continental 600mm (Cat.No. ACN-1111N)

97

-

-

... More
Providing, fitting and fixing Chrome Plated towel rack complete as directed and specified. (a) Jaquar make (i) Continental 600mm long with hanger (Cat.No. ACN-1181N)

16

-

-

... More
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (a) Jaquar make (i) Continental towel ring square (Cat.No. ACN-1121)

34

-

-

... More
Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. (a) Jaquar make (i) Continental (Cat.No. ACN-1191N)

255

-

-

... More
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified. (a) Jaquar make (ii) Continental toilet paper holder with flap (Cat.No. ACN-1153N)

10

-

-

... More
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar Make (i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)

214

-

-

... More
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)

176

-

-

... More
Supplying, fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required and complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 100mm dia.

480

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.

630

-

-

... More
Supplying,fitting and fixing H.C.I plain bend including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 100mm dia.

37

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.

240

-

-

... More
Supplying, fitting and fixing H.C.I bend with door including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 100mm dia.

22

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.

12

-

-

... More
Supplying, fitting and fixing H.C.I plain single equal junction/plain tee including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 100mm dia.

56

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.

146

-

-

... More
Supplying, fitting and fixing H.C.I single equal Tee junction with door including bolts and nuts and other fittings as required complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 100mm dia.

94

-

-

... More
Supplying, fitting and fixing H.C.I plain equal Y junction including all necessary fittings complete at all levels including below G.L as directed and specified . a) In exposed surfaces or in trenches. (ii) 100mm dia.

37

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 100mm dia.

135

-

-

... More
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.

259

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.

92

-

-

... More
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.

31

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.

31

-

-

... More
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.

22

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.

29

-

-

... More
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.

27

-

-

... More
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.

27

-

-

... More
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.

34

-

-

... More
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm x110mm

20

-

-

... More
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110 mm dia

27

-

-

... More
Providing fitting and fixing 50mm dia. HCI cowel with cement caulking complete as directed and specified.

32

-

-

... More
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110mm dia. PVC cowel of ISI make

36

-

-

... More
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. (a) 110mm dia

32

-

-

... More
Providing fiting & fixing (300x230)mm C.I. yard gully hinged Grating complete as directed and specified.

28

-

-

... More
C.P. Grating (i) 160mm dia

278

-

-

... More
Providing fiting & fixing (150X150) PVC top tile strainer complete as directed and specified.

30

-

-

... More
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified

16

-

-

... More
Providing fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified

2

-

-

... More
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (A) Exposed on walls a) 50 mm dia (Medium) ii) Using other ISI marked approved brand

90

-

-

... More
b) 40 mm dia (Medium) ii) Using other ISI marked approved brand

265

-

-

... More
c) 32 mm dia (Medium) ii) Using other ISI marked approved brand

170

-

-

... More
d) 25 mm dia (Medium) ii) Using other ISI marked approved brand

75

-

-

... More
e) 20mm dia (Medium) ii) Using other ISI marked approved brand

105

-

-

... More
f) 15 mm dia (Medium) ii) Using other ISI marked approved brand

50

-

-

... More
(B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. a) 50 mm dia (Medium) ii) Using other ISI marked approved brand

130

-

-

... More
b) 40 mm dia (Medium) ii) Using other ISI marked approved brand

42

-

-

... More
c) 32 mm dia (Medium) ii) Using other ISI marked approved brand

250

-

-

... More
d) 25 mm dia (Medium) ii) Using other ISI marked approved brand

102

-

-

... More
e) 20mm dia (Medium) ii) Using other ISI marked approved brand

380

-

-

... More
f) 15 mm dia (Medium) ii) Using other ISI marked approved brand

810

-

-

... More
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquar make (a)Continental /Clarion (ii) Bibcock long thread

53

-

-

... More
(iii)2-Way bib cock

140

-

-

... More
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (i)15mm dia

34

-

-

... More
(ii)20mm dia

21

-

-

... More
(iii) 25mm dia

23

-

-

... More
(iv)32mm dia

22

-

-

... More
(v) 40mm dia

22

-

-

... More
(v) 50mm dia

7

-

-

... More
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar (b) Queen's collection/ The Stealth Ranger (For VIP use. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) (i) Angular stop cock with wall flange

408

-

-

... More
(ii) Concealed stop cock with adjustable wall flange

5

-

-

... More
Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) Jaquar make a) Continental (iv) Overhead shower (ABS chrome plated) with rubit cleaning system

81

-

-

... More
Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed. Jaquar make (For VIP use. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) a) Continental / Clarion i) Central hole basin mixer without popup waste system with 450mm long copper pipes and brass nuts Cat No. 167

8

-

-

... More
Supplying, fitting and fixing Chrome Plated (C.P.) wall mixer complete as directed. Jaquar make v) Wall mixer 3 in 1 system with provision for both telephonic shower and overhead shower complete with 115mm long bend pipe Cat No.1119

81

-

-

... More
b) Queen's Collection (For VIP use only. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) i) Wall mixer with telephone shower arrangement only but without crutch Cat No.7217

2

-

-

... More
iii) Wall mixer 3 in 1 system with provision for both telephonic shower and overhead shower complete with wall flange with 115mm long bend pipe Cat No.7281

1

-

-

... More
Supplying, fitting and fixing Chrome Plated (C.P.) sink mixer complete as directed. Jaquar make a)Continental/ Clarion i) Sink mixer with swinging casted spout (wall mounted model)Cat No.309

2

-

-

... More
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaguar make (a) Continental

85

-

-

... More
(b)Long neck with areator

55

-

-

... More
Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) Jaquar brand a) Continental / Clarion i) Sink cock with swinging casted spout

1

-

-

... More
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. a) 50mm dia

6

-

-

... More
b) 40 mm dia.

2

-

-

... More
Supplying and fitting ball valve as specified and directed.. a) 25 mm dia. (gun metal)

10

-

-

... More
b) 20mm dia. (gun metal/Copper)

4

-

-

... More
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. a) 50 mm dia (Heavy type)

1

-

-

... More
Supplying fitting and fixing G.I. Foot valve with strainer including cutting necessary threads to pipes. a) 50 mm dia (Heavy type)

1

-

-

... More
Supplying fitting and fixing Pressmatic urinal valve complete as directed and specified as follows. Jaquar Make make cat no PRS - 077

59

-

-

... More
(F) REVERSE OSMOSIS (R.O)-For best Quality Drinking Water (I) KENT Grand +,15 lph,8 litres storage

4

-

-

... More
(V) Taurus 100 lph-do 100 litres storage

2

-

-

... More
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes 2000 Lt capacity water tank (a) Sintex make

15

-

-

... More
Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. 2000 Lt capacity water tank (a) Sintex make

15

-

-

... More
Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter

46

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100 mm diameter S.W. pipe

46

-

-

... More
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with water tight C.I. Cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With F.P.S. Bricks class designation 75

22

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 100 mm dia. R.C.C. pipe

51

-

-

... More
150 mm dia. R.C.C. pipe

110

-

-

... More
250 mm dia. R.C.C. pipe

110

-

-

... More
300 mm dia. R.C.C. pipe

150

-

-

... More
450 mm dia. R.C.C. pipe

10

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With F.P.S. bricks with class designation 75

17

-

-

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With F.P.S. bricks class designation 75

3

-

-

... More
Extra for depth for manholes Size 90x80 cm With F.P.S. bricks class designation 75

6

-

-

... More
Size 120x90 cm With F.P.S. bricks class designation 75

1

-

-

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: With 20 mm diameter round bar

5

-

-

... More
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with pre-cast R.C.C. vertical grating complete as per standard design : With F.P.S. Bricks

34

-

-

... More
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : With F.P.S. bricks

16

-

-

... More
Providing and fixing Heat pump for air to hot water generation, suitable for working temperature output range from 55 deg C to 60 deg C and pressure of 4.5 Kg/ sq.cm. The COP of Heat pump shall be not less than 4.0 and its heat Exchanger shall be having heat transfer area suitable for the rated capacity of 9000 Kcal/hr.The hot water storage tank cum Calorifier shall be of 1000 ltr capacity complete with all inlet/outlet, drains/return connection and nozzles as per requirement. Also it shall be supplied with Pressure gauges and dial type thermometer at inlet/ outlet ,pressure relief valve, safety valve test valve, etc. Insulation shall be as per specification of piping and finally cladded with 24 gauge aluminium sheet with proper overlaps The system shall be supplied with complete electronic control system for its automatic operation and required numbers of starter for pumps for reciculation of hot water between heat pump heatexchanger and calorifier tank and domestic reciculation pump in between calorifier to domestic supply/return (BRAND - VENUS)

3

-

-

... More
Providing and fixing centrifugal hot water circulation vertical/horizontal pumps of SS Body/ impellers and S.S. wetted parts with mechanical seal, capable of handling hot water of 90 deg C at required flow and head, suitable for operating Single/three phase, 50 Hz., 240/415 V. The pump shall be suitable for temperature upto 90 deg C and shall have low NPSH. (BRAND - GRUNDFOS/ DP HOLLAND) Capacity : 50 LPM Head : 08 MWC Motor : as per manufacturer recommendations (Performance curve of the pumps shall be submitted alongwith technical datasheet)

3

-

-

... More
Capacity : 75 LPM Head : 15 MWC Motor : as per manufacturer recommendations (Performance curve of the pumps shall be submitted alongwith technical datasheet)

3

-

-

... More
Providing & fixing brass/G.M/bronze/cast steel body ball valve with screwed female ends, suitable for hot water of temperature up to 90 deg C, with stainless steel ball and spindle, glass filled Teflon seating and gland packing, quarter turn lever operated full bore design, hydraulically tested to 20 kg/sqcm. (BRAND - SKS/ CIMBERIO) 15 mm nominal bore

2

-

-

... More
25 mm nominal bore

25

-

-

... More
32 mm nominal bore

12

-

-

... More
40 mm nominal bore

2

-

-

... More
Providing and fixing Balancing valve for hot water of temperature upto 90 Deg C 25 mm nominal bore

4

-

-

... More
Providing & fixing brass/G.M/bronze/cast steel body Spring loaded Non- Return valve with screwed female ends, suitable for hot water of temperature up to 80 deg C, glass filled Teflon seating and hydraulically tested to 20 kg/sqcm. 25 mm nominal bore

8

-

-

... More
32 mm nominal bore

2

-

-

... More
Providing and fixing rate of water flow meter with direct reading dial in litres with all internal parts in gunmetal or brass, strainer, flanged distance piece for easy removal in future, 100 mm dia. including necessary test certificate for the meter from Local Municipal Authorities/ISI marked. 32mm nominal bore

2

-

-

... More
Providing and fixing G.I. pipes complete (IS: 1239 Medium class) with G.I.fittings, flanges & clamps, including cutting and making good the walls etc. complete( for internal and external work) 15 mm nominal bore

4

-

-

... More
20 mm nominal bore

4

-

-

... More
25 mm nominal bore

22

-

-

... More
32 mm nominal bore

30

-

-

... More
40 mm nominal bore

4

-

-

... More
Providing and fixing insulation to hot water piping with specified thickness in the table of technical specification with resin bonded mineral wool preformed pipe sections over approved primer and sealing with 24 gauge aluminium cladding in an approved manner in accordance with the specifications. (For GI pipe) 15 mm nominal bore

12

-

-

... More
20 mm nominal bore

12

-

-

... More
25 mm nominal bore

36

-

-

... More
32 mm nominal bore

40

-

-

... More
40 mm nominal bore

20

-

-

... More
Providing 9 mm thick closed-cell expanded synthetic rubber pipe sleeve insulation to hot water lines in wall-chase/buried in floor applied with a primer coat as recommended by manufacturer complete. (for G.I. Pipes) 25.32 nominal size

24

-

-

... More
32.40 nominal size

24

-

-

... More
Providing and fixing fully Submersible Centrifugal type pumps for Sewerage lifting with motor (suitable for 40mm thick solid handling capacity ) having CI construction suitable for operation on 415/440 V 13h 50 cycle A/C power supply with level controllers, low/high level alarm probes cable/ control wiring etc as per 3.32 - i) of technical specification. Capacity - 12 - 15 cu.m/hr., Head 8 - 10 mtr. Solid handling capacity - 40 mm minimum.

2

-

-

... More
Manually operated SS fine screen bar as per specification 3.32 - ii)

2

-

-

... More
Providing and fixing fully Submersible Centrifugal type pumps for Sewerage lifting with motor (suitable for 15mm thick solid handling capacity ) having CI construction suitable for operation on 415/440 V 13h 50 cycle A/C power supply as per 3.32 - iii) of technical specification operated from local control panel. Capacity -2.0 cu.m/hr., Head 8 - 10 mtr. Solid handling capacity - 25 -40 mm minimum.

3

-

-

... More
M.S. fabricated SAFF TANK epoxy painted from out side and internals as per specification 3.32 - v).

1

-

-

... More
M.S. fabricated and epoxy painted TUBE SETTLERS as per specification 3.32 - vi).

1

-

-

... More
PVC SAFF Media as per specification 3.32 - vii)

1

-

-

... More
Tube Deck Media as per specification 3.32 - viii)

1

-

-

... More
Sludge re-circulation and excess sludge disposal PUMP as per specification 3.32 - ix) Capacity - 5 cu.m/hr., Head - 12 - 15 mtr

2

-

-

... More
Air blower capacity 60 cu.m/hr. @ 0.5 bar pressure for Areation system in equalisation Tank, SAFF Tank, Sludge Holding Tank and scouring bed of PSF & ACF as per specification 3.32 - x)

2

-

-

... More
Sludge feed pumps for transfer of sludge in CENTRIFUGE as per specification 3.32 - xii) Capacity - 2 cu.m/hr., head 5 mtr.

2

-

-

... More
CENTRIFUGE and accessories as per specification 3.32 - xiii)

1

-

-

... More
Pressure sand filter fabricated as per specification 3.50 - a - v) of capacity - 10 cu.m/hr., with all interconnecting face piping, flow indicator, quantity meter and other accessories. (Rate of flow not to exceed 12 cu.m/hr/sq.mtr. of surface area). Dia : 1300mm

1

-

-

... More
Activated carbon filter fabricated as per specification 3.50 - a - v) of capacity - 10 cu.m/hr., with all interconnecting face piping, flow indicator, quantity meter and other accessories. (Rate of flow not to exceed 10 cu.m/hr/sq.mtr. of surface area). Dia : 1400mm

1

-

-

... More
Providing and fixing Centrifugal Horizontal type Filter Feed pumps for clear water lifting with motor (suitable for 10mm thick solid handling capacity ) having CI body, Bronze Impeller & SS Shaft suitable for operation on 415/440 V 13h 50 cycle A/C power supply as per 3.32 - xiv) of technical specification operated from local control panel. Capacity - 15 cu.m/hr., head - 30 mtr

2

-

-

... More
Providing and fixing Centrifugal Horizontal type Treated Water Transfer pumps for clear water lifting with motor (suitable for 10mm thick solid handling capacity ) having CI body, Bronze Impeller & SS Shaft suitable for operation on 415/440 V 13h 50 cycle A/C power supply as per 3.32 - xiv) of technical specification operated from local control panel. Capacity - 15 cu.m/hr., head - 30 mtr

2

-

-

... More
Control cum power panel as per specification 3.32 - xv) for BOQ item No 1,3, 8, 9, 10, 11, 14, 15 and all dosing pumps inside STP area with IP - 54 classification. Also Microprocessor controller with VFD drive for pump mention in item no 15 to make the transfer in hydropneumatic mode of operation.

1

-

-

... More
Chemical dosing system of capacity 0-6 LPH with 100Litrs dosing tank for chlorinisation

1

-

-

... More
Electrical and Instrumentation work as per specification 3.50 - d) and 3.50 - e)

1

-

-

... More
Interconnecting piping to the various unit within the STP area battery limits as per specification 3.50 - b)

1

-

-

... More
All valves installed within the STP area battery limits for piping as per specification 3.50 - c) with all asscessories.

1

-

-

... More
Painting of STP equipments, piping and concrete surface as per specification 3.50 - f) in all respects.

1

-

-

... More
Providing and fixing membrane type Air Diffuser of size: 63mm x 600mm having 5 - 6 cum/hr flow. Air grid shall be in SAFF Tank, Sludge Holding Tank, & Equalisation Tank. Minimum Quantity : 12 Nos.

1

-

-

... More
Operation and maintenance of system for 3 months as per specification 3.60

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.