Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_589380_1Bid Award Id
ViewTender No
8664/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Material and labour for gas charging R410A/R32 /R134A in the system including replacement of capillary tube and strainer for proper cooling of window type air conditioner of capacity 1.5 ton, complete all as specified and as directed by Engineer-in-charge.
11
-
-
S&F in repair sensor assembly of 1.5/2.0 ton capacity for different make of the window type air conditioner, complete all as specified and as directed by Engineer-in-charge.
20
-
-
S&F in repair of starting relay assembly for different make of the window type air conditioner of capacity 1.5 ton at site, complete all as specified and as directed by Engineer-in-charge.
30
-
-
M&L for Installation/Shifting of window type AC of capacity 1.5/2.0 ton including gas recharging and fixtures such as bracket ,bolt, nuts wall drilling, complete all as specified and as directed by Engineer-in-charge.
10
-
-
S&F in repair thermostats switch complete for different make and capacity of the window type air conditioner of capacity 1.5/2.0 ton, complete all as specified and as directed by Engineer-in-charge.
40
-
-
S&F in repair overload protector relay of different make window type A/C of capacity 1.5 ton aftertaking down old unserciveable worn out overload protector, complete all as specified and as directed by Engineer-in-charge.
42
-
-
S&F in repair starting capacitor for different make air conditioners of 1.5/2.0 ton capacity after taking down old unserciveable worn out starting capacitor, complete all as specified and as directed by Engineer-in-charge.
45
-
-
S&F in repair of running capacitor of different make window type AC, capacity 1.5/2.0 ton after taking down old unserciveable old worn out running capacitor, complete all as specified and as directed by Engineer-in-charge.
45
-
-
S&F in repair capacitor for blower motor of window type AC 1.5/2.0 ton capacity after taking down old unserciveable worn out capacitor, complete all as specified and as directed by Engineer-in-charge.
25
-
-
S&F in repair front grill of different make and size for window type air conditioner of capacity 1.5/2.0 ton, complete all as specified and as directed by Engineer-in-charge.
10
-
-
S&F in repair of air filter with all other necessary fittings to the system for window type AC 1.5/2.0 ton capacity, complete all as specified and as directed by Engineer-in-charge.
42
-
-
S&F in repair of condensor coil assembly copper with all other necessary fittings to the system for window type AC 1.5/2.0 ton capacity, complete all as specified and as directed by Engineer-in-charge.
5
-
-
S&F in repair of blower motor for 1.5 ton capacity window type AC as required at site, complete all as specified and as directed by Engineer-in-charge.
2
-
-
Taking out outdoor unit stand for window type AC made of MS sheet from the existing places and making good fitting with addition/ alteration by jointing welding of MS sheet and refixing the air conditioner in existing places properlyincluding making the air tight fitting from the sides of the unit, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F in repair of PCB panel circuit for window type AC of capacity 1.5/2.0 ton of different make as required at site, complete all as specified and as directed by Engineer-in-charge.
14
-
-
Disconnecting the blower motor from the system for repairing & rewinding to the motor with suitable gauge of copper enameled wire including replacement two Nos of bushes & bearing reconnecting the blower motor of the system properly making electrical connecting for proper function of AC 1.5 ton capacity, complete all as specified and as directed by Engineer-in-charge.
10
-
-
Taking out existing split AC of capacity 1.5/2Ton by carefully disconnecting existing electrical connection, removing aside, servicing after proper cleaning and refixing including all electrical connections, checking for leakage etc if any, complete all as specified and as directed by Engineer-in-charge.
58
-
-
M&L installation/shifting of split AC of capacity 1.5/2.0 ton when and where required, including gas recharge and fixtures such as bracket ,bolt, nuts wall drilling, complete all as specified and as directed by Engineer-in-charge.
10
-
-
M&L for leakage testing, flushing and gas charging including supply of gas for 1.5 ton split AC capacity with R410A/R32 /R134A refrigerant and testing, complete all as specified and as directed by Engineer-in-charge.
10
-
-
M&L for leakage testing, flushing and gas charging including supply of gas for 2.0 ton split AC capacity with R410A/R32 /R134A refrigerant and testing, complete all as specified and as directed by Engineer-in-charge.
6
-
-
S&F in repair of indoor unit air filter for split AC of capacity 1.5/2 ton capacity, complete all as specified and as directed by Engineer-in-charge.
15
-
-
S&F in repair of remote control of split AC 1.5/2.0 ton capacity with PCB as per existing make, complete all as specified and as directed by Engineer-in-charge.
12
-
-
S&F in repair of remote control of split AC with inverter type 1.5/2.0 ton capacity with PCB as per existing make, complete all as specified and as directed by Engineer-in-charge.
6
-
-
S&F in repair of fan blower motor of 1.5 ton split AC capacity as per site requirement of existing make available at site, complete all as specified and as directed by Engineer-in-charge.
5
-
-
S&F in repair of fan blower motor of 2.0 ton split AC capacity as per site requirement of existing make available at site, complete all as specified and as directed by Engineer-in-charge.
4
-
-
S&F in repair of ODU stand/bracket for split AC of 1.5/2 ton capacity including fitting such as wall bracket ,nuts ,bolts, MS stands etc, complete all as specified and as directed by Engineer-in-charge.
10
-
-
S&F in repair of thermostate suitable for split AC capacity as per site requirement, complete all as specified and as directed by Engineer-in-charge.
30
-
-
S&F in repair of relay assembly suitable for split AC capacity as per site requirement, complete all as specified and as directed by Engineer-in-charge.
35
-
-
S&F in repair of out door unit copper condensing coil for 1.5 ton split AC capacity as per site requirement, complete all as specified and as directed by Engineer-in-charge.
8
-
-
S&F in repair of out door unit copper condensing coil for 2.0 ton split AC capacity as per site requirement, complete all as specified and as directed by Engineer-in-charge.
6
-
-
S&F in repair of strainer for 1.5/2.0 ton split AC capacity as per site requirement, complete all as specified and as directed by Engineer-in-charge.
18
-
-
S&F in repair of running capacitor suitable for AC 1.5/2 ton capacity, complete all as specified and as directed by Engineer-in-charge.
40
-
-
S&F in repair of starting capacitor suitable for AC 1.5/2 ton capacity, complete all as specified and as directed by Engineer-in-charge.
42
-
-
S&F in repair of overload protection for 1.5/2.0 ton split AC capacity as per site requirement, complete all as specified and as directed by Engineer-in-charge.
38
-
-
S&F hermetically sealed compressor unit for 1.5 ton split AC complete including vacuuming and gas charging and connecting all electrical and gas pipe connection and testing after taking down carefully unserviceable compressor unit from base by dismantling all electrical /gas connections, complete all as specified and as directed by Engineer-in-charge.
8
-
-
S&F hermetically sealed compressor unit for 2.0 ton split AC complete including vacuuming and gas charging and connecting all electrical and gas pipe connection and testing after taking down carefully unserviceable compressor unit from base by dismantling all electrical /gas connections, complete all as specified and as directed by Engineer-in-charge.
2
-
-
S&F in repair of copper tubing of 1/2"/3/8"/1/4" including teflon capping, complete all as specified and as directed by Engineer-in-charge.
80
-
-
S&F in repair of water tube PVC 1/2" to 1/4" for connection of water outlet line including clamp and necessary arrangement, complete all as specified and as directed by Engineer-in-charge.
50
-
-
Disconnecting refrigerator of capacity upto 315 ltrs for cleaning with blower & soap water solution making dust free to the system, tighting all nuts bolts screws etc, and spray painting over a coat of red oxide primer matching with the exisitng colour and refixing the refrigerators in existing places properly, complete all as specified and as directed by Engineer-in-charge.
30
-
-
Material and labour refrigerant gas charging in the system including replacement of capillary tube and strainer upto 300 ltrs capacity refrigerator, complete all as specified and as directed by Engineer-in-charge.
20
-
-
S&F in repair of box type relay assembly of refrigerator upto 300 ltrs capacity, complete all as specified and as directed by Engineer-in-charge.
22
-
-
S&F in repair of thermostat for refrigerator upto 300 ltrs capacity, complete all as specified and as directed by Engineer-in-charge.
25
-
-
S&F in repair of cooling coil complete for refrigerators of different make of capacity upto 300 ltrs capacity, complete all as specified and as directed by Engineer-in-charge.
11
-
-
S&F in repair of door gasket of refrigerator upto 315 ltrs capacity, complete all as specified and as directed by Engineer-in-charge.
8
-
-
S&F in repair of PCB for refrigerator of any capacity and type (single/double), complete all as specified and as directed by Engineer-in-charge.
18
-
-
S&F in repair of PVC stand for refrigerator of any capacity, complete all as specified and as directed by Engineer-in-charge.
15
-
-
S&F in repair of hermetically sealed compressor of capacity 300/315 ltrs and re-connecting the compressor to the system properly. including recharging refrigerant gas, complete all as specified and as directed by Engineer-in-charge.
8
-
-
S&F in repair of hermetically sealed compressor of capacity 250 to 299 ltrs and re-connecting the compressor to the system properly. including recharging refrigerant gas, complete all as specified and as directed by Engineer-in-charge.
5
-
-
S&F in repair of hermetically sealed compressor of capacity 200 to 249 ltrs and re-connecting the compressor to the system properly. including recharging refrigerant gas, complete all as specified and as directed by Engineer-in-charge.
6
-
-
S&F in repair of hermetically sealed compressor of capacity 165 to 199 ltrs and re-connecting the compressor to the system properly. including recharging refrigerant gas, complete all as specified and as directed by Engineer-in-charge.
4
-
-
Supply only remote for 1.5/2 ton window type as per sample including batttries complete all as specified and directed.
15
-
-
M&L for disconnecting the hermetically sealed compressor from the system, repairing/reconditioning of the defective compressor and reconnecting the compressor to the system properly for water cooler of capacity upto 150 ltrs, complete all as specified and as directed by Engineer-in-charge.
14
-
-
M&L for cleaning the system with CTC and gas charging the refrigerant including replacing strainer and rectification of leakages in the system for water cooler having storage capacity of 150 ltrs, complete all as specified and as directed by Engineer-in-charge.
35
-
-
M&L for servicing, Cleaning and Spray painting including taking out Water Cooler of upto 150 ltrs capacity from the existing places, clearing with blower & soap water solution making dust free to the system, tightening all nuts bolts screws etc, oiling to blower motor, refixing the Water Cooler in existing places after testing, complete all as specified and as directed by Engineer-in-charge.
40
-
-
S&F in repair of overload protection relay suitable for water coolers 120/150 Ltrs capacity, complete all as specified and as directed by Engineer-in-charge.
35
-
-
S&F in repair of thermostate including switch for water coolers of capacity 40/80, 80/120,120/150 Ltrs, complete all as specified and as directed by Engineer-in-charge.
42
-
-
S&F in repair of starting capacitor of suitable capacity for 40/80, 80/120,120/150 Ltrs, complete all as specified and as directed by Engineer-in-charge.
45
-
-
S&F in repair of running capacitor of suitable capacity for 40/80, 80/120,120/150 Ltrs, complete all as specified and as directed by Engineer-in-charge.
45
-
-
S&F in repair of RO booster pump head and fixing clamp including testing and commission upto 15/20 ltrs per hours capacity, complete all as specified and as directed by Engineer-in-charge.
4
-
-
S&F in repair of RO PP/wound/carben/GAC/alkaline filter cartridge including testing and commission upto 15/20 ltrs per hours capacity, complete all as specified and as directed by Engineer-in-charge.
4
-
-
S&F in repair of water filter cartridge of suitable capacity all as required at site for aquagauard upto 150 ltrs capacity, complete all as specified and as directed by Engineer-in-charge.
5
-
-
S&F in repair of blue housing SOR of suitable capacity all as reqired at site for RO upto 15/20 ltrs per hours capacity, complete all as specified and as directed by Engineer-in-charge.
7
-
-
S&F in repair of Bib Cock Push Type self closing of stainless steel of appropiate size as per site requirement, complete all as specified and as directed by Engineer-in-charge.
4
-
-
Disconnecting any capacity upto 405 ltrs deep freezer from the system for Servicing/cleaning, taking out deep freezer from the existing places, clearing with blower & soap water solution making dust free to the system, tighting all nuts bolts screws etc,includind spray painting over a coat of red oxide prime, complete all as specified and as directed by Engineer-in-charge.
25
-
-
S&F in repair fan blower motor for Deep freezer up to 450 ltr as per site requirement of existing make available at site complete all as specified and directed.
8
-
-
M&L for testing and gas charging in the system upto 405 ltrs capacity deep freezer, complete all as specified and as directed by Engineer-in-charge.
22
-
-
S&F in repair of door gasket of deep freezer upto 405 ltrs capacity, complete all as specified and as directed by Engineer-in-charge.
3
-
-
S&F in repair of compressor of suitable or required capacity upto 405 ltrs complete from the existing location and reconnecting the compressor to the system properly. including recharging refrigerant gas, complete all as specified and as directed by Engineer-in-charge.
14
-
-
Supply and fix in repair starting capacitor of suitable Deep freezer up to capacity 405 ltr complete all as specified and as directed.
12
-
-
Supply and fix in repair running capacitor of suitable Deep freezer up to capacity 405 ltr complete all as specified and as directed.
12
-
-
S&F in repair of thermostat of deep freezers of different make as required upto 405 ltrs capacity, complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements