Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date19 Oct 2024
Closing Date16 Nov 2024
Tender Amount₹ 39,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sequence controller LOA to the bentone burner

1

-

-

... More
Solenoidal coil with cable

1

-

-

... More
Photocell

1

-

-

... More
M&L for overhauling the ID fan, blower, motor 5HP by repairing / replacing the damaged / worn out parts with new ones wherever required and testing on completion complete all as specified and as directed

1

-

-

... More
M&L for preparation of surfaces of oil fired Incinerator by scrubbing off old treatment and painting the primary chamber, secondary chamber, steel scrubber tank, droplet, blower motor and exhaust motor system, including connecting pipe with two coats of synthetic enamel paint (of approved tint) over a coat of zinc chrome primer complete all as specified and as directed

1

-

-

... More
S&F maintenance free lead acid battery 12V, 180Ah capacity with brass terminals including testing on load including taking off old battery and disposing off complete all as specified and as directed

2

-

-

... More
S&F filter tank of incinerator fabricated out of 10mm thick MS sheet, made to cylindrical shape required as per site duly painted entirely with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer including taking off old tank and disposing off complete all as specified and as directed

1

-

-

... More
Maintenance and servicing to DG sets including attending faults on call basis for normal repairs including replacement of defective and worn out parts/spares viz. filters, gaskets, V- belts, engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and rectifying faults of AMF panels, etc. tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolant levels complete all as specified and as directed of the following capacities: Notes: (i) All items viz. cleaning agent, cotton waste, grease, minor items such as washer, nuts, bolts etc are required for carrying out the normal maintenance of the engine, mechanic charges and any specialized machine work from outside workshop if requred shall be included in the quoted rates (ii) Fresh engine oil/spare parts for DG sets shall be measured and paid separately under respecitve items as detailed hereafter. Labour for such fixing shall be included in the quoted rates (iii) During maintenance/servicing of DG set, complete DG set shall be checked properly and all setting shall be done properly

-

-

-

... More
Notes for item No. 11 contd... (iv) The maintenance/servicing of DG set by authorized service agency of authorised service center of the OEM i.e. Kirloskar/ Greaves Cotton only (v) Servicing shall be carried out after every 500hrs run or after 6months whichever is earlier (vi) Sites shall be at Masimpur and Kumbhirgram. (vii) All the above including all carting, lifting, loading, unloading, etc. shall be deemed to be included in the quoted rate and no claim whatsoever shall be entertained

-

-

-

... More
125kVA

4

-

-

... More
82.5kVA

1

-

-

... More
63kVA

1

-

-

... More
62.5kVA

4

-

-

... More
45kVA

1

-

-

... More
25kVA

1

-

-

... More
Supply only the following spare parts as per site requirement suitable for 125KVA capacity DG set complete all as specified

-

-

-

... More
Engine oil in 20litres can

2

-

-

... More
Spin on filter for lubricating oil

9

-

-

... More
Fuel Filter Kit 1.1litre

3

-

-

... More
Air cleaner element

3

-

-

... More
Rubber Hose (Compressor outlet)-K24 Turbo

3

-

-

... More
Fuel pipe (7.5,14x14B,700 WB)

3

-

-

... More
Banjo bolt

12

-

-

... More
Fuel pipe 8.0,14B, 1000WB

3

-

-

... More
Primary element

6

-

-

... More
Secondary element

6

-

-

... More
Primary element (6H.411.02.0.00)

3

-

-

... More
Poly V Belt

3

-

-

... More
Poly V Belt for (7PK BelT)

3

-

-

... More
Hose [Raditor to Water pump pipe (45x45x130L)]

6

-

-

... More
Hose [Pipe to water pump (45x45x80L)]

6

-

-

... More
Hose clip (54mm)

18

-

-

... More
Drive Hose clip (70mm)

12

-

-

... More
Copper washer (14x18mm)

18

-

-

... More
Supply only the following spare parts as per site requirement suitable for 62.5/63KVA capacity DG set complete all as specified

-

-

-

... More
Engine oil in 13litres can

4

-

-

... More
Spin on filter for lubricating oil

5

-

-

... More
Fuel filter element pre (Bosch Part No 14574)

10

-

-

... More
Fuel filter element micro (Bosch Part No 9451)

5

-

-

... More
Primary element (KKFL make KFA -02-1-7047 for KFA)

5

-

-

... More
Secondary element (KKFL NO KFA -02-1-7048)

5

-

-

... More
V Belt( XPA 1250) COGGD

5

-

-

... More
LO supply hose (FIP) M10 Banjo Ends X235L

5

-

-

... More
Hose radiator to water pump pipe

5

-

-

... More
Hose clip (54mm)

20

-

-

... More
Hose (pipe to water pump)

5

-

-

... More
Worm drive hose clip (70mm)

10

-

-

... More
Fuel pipe (7.5,14 x 14 B, 700 WB)

5

-

-

... More
Copper washer (14x18mm)

30

-

-

... More
Lube oil pressure sensor (sensor+switch), VDO

4

-

-

... More
K934 controller with 4-20MA updated version V3.G.4

1

-

-

... More
2 position selector actuator with element

2

-

-

... More
Copper wire 1.5sqmm

80

-

-

... More
Starter mico (Bosch) F002 G2 645/F002 G20 993

2

-

-

... More
Supply only the following spare parts as per site requirement suitable for 45KVA capacity DG set complete all as specified

-

-

-

... More
Engine oil 13litres can

1

-

-

... More
Spin on filter for lubricating oil

1

-

-

... More
Fuel filter element pre (Bosch Part No 14574)

2

-

-

... More
Fuel filter element Micro (Bosch Part No 9451)

1

-

-

... More
Main element for air cleaner

1

-

-

... More
V Belt( XPA 1250) COGGED

2

-

-

... More
Hose radiator to water pump pipe (45x45x130L)

1

-

-

... More
Hose (pipe to water pump)

1

-

-

... More
Rubber hose (compressor outlet)-K24 Turbor

1

-

-

... More
Hose clip (54mm)

4

-

-

... More
Worm drive hose clip (70mm)

2

-

-

... More
Fuel pipe (9.0,14x14B,520WB)

1

-

-

... More
Copper washer (14x18mm)

6

-

-

... More
Lube oil pressure sensor (Sensor+Switch), VDO

1

-

-

... More
LO supply hose (FIP) M10 Banjo Ends X235L

3

-

-

... More
Supply only the following spare parts as per site requirement suitable for 25KVA capacity DG set complete all as specified

-

-

-

... More
Engine oil 5litres can

2

-

-

... More
Fuel filter kit (0.5litre)

1

-

-

... More
Main element for air cleaner

1

-

-

... More
V Belt B 48 1262 Length

1

-

-

... More
Hose (water pipe to adaptor)

1

-

-

... More
Hose (radiator to water pipe)

1

-

-

... More
Hose (radiator to thermostat)

1

-

-

... More
Hose

6

-

-

... More
Battery distilled water (2litres bottle)

1

-

-

... More
Expansion belloe (two ply)

10

-

-

... More
Copper washer (14x18)

5

-

-

... More
Fuel pipe (7.5,14 x 14 B, 700 WB)

4

-

-

... More
Hose clip (48mm)

1

-

-

... More
Coolant premixed 10litres can

1

-

-

... More
Coolant premixed 5litres can

1

-

-

... More
V Belt B 47 1237 Length

2

-

-

... More
Diesel tank cap

1

-

-

... More
Thermostat element

1

-

-

... More
Joint for thermostat cover

1

-

-

... More
Water pump with spindle Brg. and Unitized seal

1

-

-

... More
Anabond 666 25GM

3

-

-

... More
Supply and filling up / applying petrolium jelly (1kg plastic sealed container) complete all as specified Make: Indian oil/ Hindustan Petrolium/ Castrol/ BPCL

5

-

-

... More
Supply and filling distilled water for topping up in lead acid batteries complete all as specified and as directed

100

-

-

... More
Supplying and filling electrolyte of suitable specific gravity for lead acid batteries in sealed containers complete all as specified and as directed

12

-

-

... More
S&F battery comnnecting wire, copper, 1.5m long with 2Nos suitable clamps on one side and 2Nos lugs on other side of suitable sizes and fixed including taking out worn out battery clamp and connecting wire and disposing off complete all as specified as directed.

6

-

-

... More
S&F battery terminal, brass clamps including removal of damaged terminal compete all as specified and as directed

8

-

-

... More
M&L for disconnecting all electrical connections from DG set 25/45/62.5/63/125KVA, removing alternator from base plate by opening nuts & bolts taking out to workshop for rewinding (as per relevant IS) and reinstalling in position including testing and commissioning complete all as specified and as directed

7

-

-

... More
M&L for repairing and calibration of FIP & injector including all necessary minor spare parts for DG Sets of under mentioned capacities complete all as specified and as directed

-

-

-

... More
DG set 125kVA

2

-

-

... More
DG set 63/62.5kVA

2

-

-

... More
DG set 45kVA

1

-

-

... More
DG set 25kVA

1

-

-

... More
M&L for dismantling and taking out radiator and strip opening radiator assembly, for servicing mechanically, proper cleaning of tubes using de-scaling solution, including repair to water tubes and top/ bottom tanks by soldering / gas welding to check leakages of tubes/tanks including replacement of gasket, nut bolts, etc. ensuring perfect leak proof service, re-assembling and fixing the same in position and testing the system complete all as specified and as directed for the following capacities of DG sets of any make: Notes: The quoted rate shall include the following: (i) Fixing of serviceable parts in position and replacement of unserviceable spares with new spares (ii) Replacement of small/minor parts viz. nuts, bolts, washers, gaskets / packing, etc. (iii) Loading, unloading, carting to/fro to workshop (iv) Complete load testing after complete repair and re-installation as per relevant IS and as directed

-

-

-

... More
125kVA

1

-

-

... More
62.5/63kVA

2

-

-

... More
45kVA

1

-

-

... More
25kVA

1

-

-

... More
M&L for taking out of unservicable self starter 12V of 62.5kVA installed at UAV Tps Kumbhigram and connected unserviceable spares of electric wiring and carring out repairs and overhauling the self starter, engine, replacing the armature, carbon brush, bearing, bendix penion, solenoid switch, bearing, tapping of field coil refixing of all components and refixing in existing position including testing complete all as specified and as directed

1

-

-

... More
M&L for taking out of unservicable self starter 12V of 125kVA installed at GE Silchar Masimpur and connected unserviceable spares of electric wiring and carring out repairs and overhauling the self starter, engine, replacing the armature, carbon brush, bearing, bendix penion, solenoid switch, bearing, tapping of field coil refixing of all components and refixing in existing position including testing complete all as specified and as directed

1

-

-

... More
S&F in repair battery charging circuit suitable for 12/24V, DC in existing DG set panel board including addition/ alteration in wiring system with auto transformer, diodes, filter circiut, condensors, DC ammeter, DC volt meter with selector switches and indicating bulbs, etc. complete all as specified and as directed

2

-

-

... More
S&F AVR (automatic voltage regulator) control unit assembly suitable for 25kVA to 125kVA DG set including taking out old unserviceable AVR and dsiposin off compete all as specified and as directed

3

-

-

... More
S&F power contactor ML -12, 2 NO + 2 NC along with 1 aux contact block 415V, 50Hz AC suitable for DG set control panel/ AMF panel including taking off old unserviceable power contactor compete all as specified and as directed

2

-

-

... More
S&F power contactor MNX 70-2P along with 1 aux contact block 415V, 50Hz AC suitable for DG set control panel/ AMF panel including taking off old unserviceable power contactor compete all as specified and as directed

2

-

-

... More
S&F power contactor MNX 225, 2 NO + 2 NC along with 1 aux contact block 415V, 50Hz AC suitable for DG set control panel/ AMF panel including taking off old unserviceable power contactor compete all as specified and as directed

2

-

-

... More
S&F solenoid valve suitable for the following capaities of DG sets including taking out old and testing for smooth functioning complete all specified and as directed

-

-

-

... More
45KVA to 63KVA

2

-

-

... More
125KVA

2

-

-

... More
M&L for overhauling engine of DG sets by opening the top cover including dismatlling the engine head, cylinder liner and piston assembly, crankshaft assembly, radiator fan belt and radiator fan, gear assembly,repair / replacement of parts viz. gasket, washer, 'O' ring all types, etc including grinding polishing of crank shaft, head repairing and overhauling valve seat cutting and replacing, valve tapping, fixing the head, reassembling the DG set and testing on full load as per relevant IS complete all as specified and as directed for the following capacities of DG sets: Notes: (i) Overhauling shall be got done through authorised service centres of OEM (ii) Cost of all necessary loading / unloading, carting, etc. for transorting to workshop (if required) shall be deemed to be included in quoted rate (iii) Spare parts will be measured and paid seperately under relevent items detailed hereafter

-

-

-

... More
125KVA

2

-

-

... More
63/62.5KVA

6

-

-

... More
45KVA

1

-

-

... More
25KVA

1

-

-

... More
Supply only the following spare parts as per site requirement suitable for DG sets hereinabove complete all as specified

-

-

-

... More
Cylinder liner with joint ring

10

-

-

... More
Piston assembly complete

10

-

-

... More
Piston ring set

10

-

-

... More
Bearing main KIR 6R 1080 STD

3

-

-

... More
KIR 4RTA C/G BRG, STD

2

-

-

... More
Bearing bush

8

-

-

... More
Oil seal

4

-

-

... More
Plate with rubber moulding

1

-

-

... More
Piston cooling nozzle assembly

10

-

-

... More
Bolt for cylinder head

15

-

-

... More
Gasket for cylinder head

2

-

-

... More
Valve spring

12

-

-

... More
Push rod (welded)

5

-

-

... More
Lube oil pump assembly

2

-

-

... More
Assembly for internal gear

2

-

-

... More
Thermostat element

2

-

-

... More
WP assembly with DEL volute

1

-

-

... More
Set of joint 6R108OTA 125 KVA

2

-

-

... More
Con rod assembly

4

-

-

... More
Rubber hose (compressor outlet) K-24 Turbo

2

-

-

... More
Hose for air cleaner

1

-

-

... More
Coolant premixed

24

-

-

... More
M&L for earthing with galvanised iron earth plate electrode 600x600x6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below ground level connetced with galvanised strip of size 25x4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (using 20mm graded stone aggregates), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 150mm C/C bothways and suitable handle made of 10mm dia ound bar including all necessary earthwork, excavation, returning filling in any type of soil and removing surplus earth upto a distance not exceeding 50m all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing on completion and making test points on wall as per SSR specifications complete all as specified and as directed

16

-

-

... More
Notes for serial item No. 150 : (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge

-

-

-

... More
M&L for taking down AC units for required servicing, cleaning of cooling coil, air filters/plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solutions, etc., checking serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches, knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed for the following: Notes:(a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of taking down, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate

-

-

-

... More
Split type AC 1.5/2TR

75

-

-

... More
Window type AC 1.5/2TR

20

-

-

... More
M&F for attending to complaints in case of breakdown of AC units any type at UAV Kumbhirgram whenever required, rectifying the fault and restoring the units including all necessary arrangements, T&P, etc. as required at site complete all as specified and as directed Notes: (i) The cost of replaced spare parts, gas charging will measured and paid seperately under resective item herein (ii) Complaint will be intimated by any means either written or electronic and shall be attended by the Contractor immediately within 24hrs (maximum). In the event the complaint if not attended a penalty of Rs. 500/hour beyond 24hrs shall be levied. The amount shall be deducted from immediate payments due to the Contractor (iii) The cost of transportation (to and fro) for all kind of necessary equipment/T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard shall be deemed to be included in the the quoted rate (iv) Successful restoration of AC units shall only be considered for payment purposes

80

-

-

... More
Supply, installing, testing and commissioning of compressors of AC units in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed of the following capacities: Notes: (i) Compressor units shall be from manufacturer as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum warrantee of 5years and as given by manufacturers

-

-

-

... More
2Ton

2

-

-

... More
1.5Ton

3

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in split type AC unit of any capacity including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed

70

-

-

... More
S&F the following spare parts including necessary fittings as per sample and suitable for and in maintenance of air conditioner units of capacity 1.5/2T complete all as specified

-

-

-

... More
Condensing coil assembly including necessary fittings viz. clamps, nuts, bolts, etc. including all required soldering, brazing, etc.

5

-

-

... More
Thermostat switch with regulator knob unit and necessary fittings

5

-

-

... More
Starting capacitor of 80/100/120MFD

30

-

-

... More
Selector switch with knob including necessary fittings

5

-

-

... More
Blower motor capacitor 8MFD

10

-

-

... More
Running capacitor 36MFD

10

-

-

... More
Running capacitor 50MFD

10

-

-

... More
Relay box/open type

5

-

-

... More
Remote control hand set

9

-

-

... More
Remote control PCB circuit

3

-

-

... More
Overload protector relay

5

-

-

... More
Front grill as per existing pattern including fixing screws and accessories

15

-

-

... More
Air filter

15

-

-

... More
Capillary charging

3

-

-

... More
MS stand as per approved drawing and specifics

15

-

-

... More
PVC drain pipe 15mm dia 3m long with clamp

20

-

-

... More
Blower fan motor for spilt AC units

5

-

-

... More
Blower fan motor for window AC units

5

-

-

... More
M&L for disconnecting from mains and taking down for servicing water coolers including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and making the water cooler to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop as required shall be deemed to be included in the quoted rate

-

-

-

... More
120 to 150litres

25

-

-

... More
40 to 80litres

25

-

-

... More
S&F company made new sealed compressor units for water coolers of capacity 60/120litres, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum warrantee of 5years and as given by manufacturers

5

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in water cooler units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed

45

-

-

... More
S&F in repairs blower motor assembly of water coolers of any make, as per existing including necessary fittings viz. clamps, nuts, bolts, etc. complete all as specified and as directed

10

-

-

... More
S&F in repairs condensing coil assembly of water coolers of any make, including necessary fittings viz. clamps, nuts, bolts, etc. and all required soldering, brazing, etc. complete all as specified and as directed

10

-

-

... More
Supply only the following spare parts as per sample and suitable for and in maintenance of water coolers including necessary fittings complete all as specified

-

-

-

... More
Starting capacitor 60-80Mfd

15

-

-

... More
Running capacitor 25Mfd

15

-

-

... More
Thermostatic switch with regulating knob

5

-

-

... More
Push cock, self closing chromium plated 15mm bore including nut and washer, etc.

5

-

-

... More
PVC drain pipe 1m long including clamps

10

-

-

... More
Float valve of gun metal, 15mm bore with ball

20

-

-

... More
Over load protector relay

5

-

-

... More
Running capacitor 36Mfd

5

-

-

... More
Pencil strainer

5

-

-

... More
Water Tap with 6'' concealed end pipe of size 15mm

5

-

-

... More
M&L for disconnecting from mains, for servicing refrigerators / deep freezers including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches, knobs, leakage of gas, etc. and making the deep freezer / refrigerator to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate

-

-

-

... More
230/285/286/310llitres

20

-

-

... More
165/175/185litres

20

-

-

... More
S&F company made new sealed compressor units for refrigerators, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed for the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum warrantee of 5years and as given by manufacturers

-

-

-

... More
165litres

6

-

-

... More
200/300/362litres

5

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in refrigerator units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed

40

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in deep freezer units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed

15

-

-

... More
Supply only the following spare parts as per sample and suitable for and in maintenance of refrigerators / deep freezers including necessary fittings complete all as specified and as directed

-

-

-

... More
Relay open type (over load cum relay)

2

-

-

... More
Overload protector

1

-

-

... More
Cooling coil door with locking spring

2

-

-

... More
Thermostat switch with regulating knob

4

-

-

... More
Fan motor / evaburator

5

-

-

... More
Fan blade

5

-

-

... More
Chiller tray as per existing model

8

-

-

... More
Frost free timer

2

-

-

... More
Frost free cooling coil

3

-

-

... More
Capillary charging

3

-

-

... More
Thermal fuse

3

-

-

... More
S&F in repairs capillary tube and silica drier type strainer suitable for deep freezer 200/300/345/400litres capacity complete all as specified and as directed

10

-

-

... More
S&F in repairs starting capacitor 4/6/8Mfd as per requirement at site suitable for deep freezer 200/300/345/400litres capacity complete all as specified and as directed Make: TESLA/EPCOS/SIEMENS/USHA

20

-

-

... More
S&F in repairs over load protector relay suitable for deep freezer 200/300/362litres capacity complete all as specified and as directed Make: SHRIRAM/RENUTROL/DANFOSS

15

-

-

... More
S&F in repairs thermostat switch suitable for deep freezer 200/300/362litres capacity complete all as specified and as directed Make: SHRIRAM/RENUTROL/DANFOSS

15

-

-

... More
S&F in repairs relay open type suitable for deep freezer 200/300/362litres capacity complete all as specified and as directed Make: SHRIRAM/RENUTROL/DANFOSS

15

-

-

... More
S&F in repairs fan motor suitable for deep freezer 200/300/362litres capacity complete all as specified and as directed

15

-

-

... More
M&L for repairs and maintenance of voltage stabilizer 4/5kVA of different make including replacement of worn out parts viz. volt meter, transformer, circuit plate, step-up, step-down relays, etc. and testing for proper functioning complete all as specified and as directed

30

-

-

... More
S&F in repairs single pole and neutral sheet metal enclosure powder coated with a two pin and earth plug and socket complete with and including 01No. MCB 20A SP and making good the disturbed surfaces complete all as specified and as directed

15

-

-

... More
S&F in repairs MCB, SP, 6 to 32A, 240V, 10kA, B curve complete all as specified and as directed

20

-

-

... More
M&L for submain wring using proper colour coding with 4 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 6sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including non-metallic PVC casing capping 25mm wide, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories complete all as specified and as directed Notes: (i) 4 runs of 6sqmm main cable, 1 run of earth conductors and 1 run of PVC casing capping as per item shall be measured as one length (ii) Separate casing capping shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site

100

-

-

... More
M&L for point wiring with 4sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC casing capping not less than 20mm wide and accessories surface on walls, ceiling etc. and including provision of 2.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly with 1.6mm thick pressed steel concealed terminal boxes for AC / equipment controlled by one SP / SPN MCB on independent board complete all as specified and as directed

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.