Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684408_1Tender No
8212/GE/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply only following spares / components to be incorporated against chemical Dozing pumps of make RMCO/CHEMINJECT model RPQ 40 HD high pressure single head gear motor adjustable chemical dosing (metering) pump cap. 2 to 40 US GPD @ 100 PSI & capacity or any other make / capacity complete : (a) Pump tube
1
-
-
(b) Injection check valve
1
-
-
(c) Suction Line Strainer 3/8'
1
-
-
(d) Suction / Discharge Tube
2
-
-
(e ) Check Valve / Duck Bill
2
-
-
(f ) Connecting Nut 3/8"
2
-
-
(g) Ferrule
2
-
-
Demolition of Concrete ( Unreinforced ) of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed
0.25
-
-
Material & labour for Plain Cement Conerete 1 : 3 : 6 type C2 using 40 mm graded stone agregate as in foundation/platform of pump set/pump panel & other works at different pump house complete all as specified and as directed by the Engr-in-charge.
0.25
-
-
Collection of 18 nos water samples ( RAW and Treated ) from 09 water supply installations ( Pump House No. 1, 2,3,4,5,7,8,9 & 10 ) incl water treatment plant under GE Jorhat in a special sterilized container and submitting to test laboratory for Bacteriological/Chemical analysis as per IS code and obtain test result from lab incl submitting to Engineer-in-Charge as directed. Total 09 Nos of pump houses and 09 Nos samples in a month for testing of both Raw and treated water .
Nature of Tests :-
(NOTE: Testing shall be carried out at NTC/NEIST Jorhat or any other Govt approved laboratory with prior approval of GE)
7
-
-
Collection of 09 nos water samples (Treated ) from 09 water supply installations ( Pump House No. 1, 2,3,4,5,7,8,9 & 10 ) incl water treatment plant under GE Jorhat in a special sterilized container and submitting to test laboratory for Lead analysis as per IS code and obtain test result from lab incl submitting to Engineer-in-Charge as directed. Total 09 Nos of pump houses and 09 Nos samples in a month for testing of treated water .
Nature of Tests :-
(NOTE: Testing shall be carried out at NTC/NEIST Jorhat or any other Govt approved laboratory with prior approval of GE)
7
-
-
Supply only Spiral Cap type pet sterile bottle made from BPA free material for taking samples of water all as specified & directed. complete all as specified and as directed.
20
-
-
Supply and fix in repair PE /FRP dozing tank of capacity 100 litres, 480 mm dia and 575 mm height with lid containing port hole for pouring chlorination chemical and water including provision for mounting arrangement for motor & dosing pump, solution level indication Gauge suitable for chemical dosing plant complete complete all as specified and directed.
1
-
-
Supply of chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill (dia 2.5 inches ± 0.5 inches height 10 inches+ 0.5 inches) for disinfection of drinking water with arrangement for controlled release of disinfactant in water, suitable for operation through dosing system Make- Declibac (Type Stequa 411 AEV Eqv Note- The product media should have heavy metal contaminants below detectable limits & must pass the acute toxicity test confirm to non toxicity for mammalian cells) and safe for human health safety point
5
-
-
Supply and mixing TCCA 90( Trichloroisocyanuric acid) granular for water purification and chlorinelevel control of swimming pool water complete all as specified and directed.
200
-
-
Supply and mixing blue crystal copper sulfate to maintain PH value and visibility of swimming pool water complete all as specified and directed.
75
-
-
M&L for pressure washing and cleaning thoroughly the bottom floor and inside walls of swimming pool of minimum 300000 gallons capacity after draining out of water including cleaning of joints of tiles of the pool by suitable mechanical means using mild hydrochloric acid for fungus/ algae free surfaces including removing out all dirt and foreign matters if any from the pool to a distance not exceeding 50m complete to the satisfaction of the Engineer-in-charge all as specified and directed. Notes: (a) Draining of water from the Swimming pool shall be made by the Contractor.
1
-
-
M&L for pressure washing and cleaning thoroughly the bottom and inside walls of balancing tank of the swimming pool after draining out of water by suitable mechanical means using bleaching powder including removing of sludge/ slurry/ foreign matters if any from the tank to a distance not exceeding 50m complete to the satisfaction of the Engineer-in-charge all as specified and directed. Notes: (a) Size of the Balancing tank is 3.6m length x 2.9m width and depth 4m (Approx). (b) Draining of water from the Balancing tank shall be done by the Contractor.
1
-
-
Taking down of defective motor of capacity 1 HP, 415 Volt, 1440 RPM with gear assembly from chemical dozing system / Water filteration in swimming pool after disconnecting electric connection and servicing the motor & gear assembly for proper functioning including replacement of burnt copper winding, oiling and greasing etc, and refixing back in same position complete all as specified and as directed. Note: Spares such as NRV, Bearing, Rubber coupling will be deemed to be included in rate quoted against above item.
2
-
-
M & L PVC Suction hose pipe of size 40 mm dia, ISI marked including taking down the existing hose pipe for swimming pool complete all as specified and directed.
25
-
-
Supply & Fixing Safe water pre-filter capsule suitable for accommodating one unit of Prefil sealed refill for corrosion & scale inhibition as well as sediment filtration sealed of 51.0 cm. for drinking water applications, ( before PVC Tank Inlet ) with spcifications such as pressure: 7 Bar, Temperature: 35°C Max, End connections: 1½ inch, Installing location: Vertical Spindle all as specified and directed by Engr-in-Charge
5
-
-
Supply and Fixing Safe water pre-filter capsule suitable for accommodating one unit of Prefil corrosion & scale inhibitor sealed refill of 12.7 cm. for drinking water applications of following specifications: Flow Rate: 1,000 LPH Pressure: 1.5 Mpa Temperature: 35°C Max. End connections: ½ inch ( before Geyser / Kitchen Tap ) Installing location: Vertical Spindle Environment: Cool dry place away from direct sunlight Backwash option: manual key all as specified and directed by Engr-in-Charge.
15
-
-
Supply and Fixing Safe water pre-filter corrosion & scale inhibitor refills for Prefil capsules for drinking water applications of following specifications: Height: 12.7 cm Must be capable of forming protective films on pipe interiors Must prevent precipitation of Calcium, Magnesium & Iron Minimise red water problem by complexation with Iron Filter porosity: 180 Microns Flow Rate: 1,000 LPH Pressure: 1.5 Mpa Temperature: 45°C all as specified and directed by Engr-in-Charge.
15
-
-
Supply & fixing in repairs NRV assembly 20mm, PVC for inlet and outlet pipes complete all as specified and directed.
5
-
-
S & F in repair for 50 mm outer diameter of 3- layer PP-R Polypropylene random copolymer) pipes, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
40
-
-
S & F in repair for 32 mm outer diameter of 3- layer PP-R Polypropylene random copolymer) pipes, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
120
-
-
S & F in repair for 25 mm outer diameter of 3- layer PP-R Polypropylene random copolymer) pipes, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
100
-
-
S & F in repair for 32 mm gate valve for 3- layer PP-R Polypropylene random copolymer) pipes, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings complete all as specified and as directed.
2
-
-
S&F in repairs GI steel water tubings , medium grade galvanised with all fittings 15 mm bore , fixed to wall/pole with suitable size of MS flat clamps all as specified and directed .
35
-
-
Excavation in trench in soft/loose soil not exc. 1.5 mtr width and n. exc 1.5 mtr in depth and getting out for taking up or laying water pipe line for soft / loose soil.
28
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick as in soft/loose soil.
25.2
-
-
Removing excavating material n.exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
2.8
-
-
S & F in repair for 50 x 40 mm brass threaded socket for 3- layer PP-R Polypropylene random copolymer) pipes, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings complete all as specified and as directed.
2
-
-
S & F in repair for 32 x 25 mm brass threaded socket for 3- layer PP-R Polypropylene random copolymer) pipes, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings complete all as specified and as directed.
8
-
-
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%