Bodoland Territorial Council Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Bodoland Territorial Council - BTC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date15 Jul 2024
Closing Date3 Aug 2024
Tender Amount₹ 95,23,787 
Notes
Download

Costs

Summary

Infrastructure Development Of Kalaguru Bishnu Rabha Jr. College, Orang In Udalguri District. (tn_03_1)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- 500D or more.

13732.35

-

-

... More
CEMENT CONCRETE WORK: 4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).

10.57

-

-

... More
4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.4 1:2:4 (1 Cement 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 40 mm nominal size derived from natural sources.

25.76

-

-

... More
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level: 5.1.2 1:1.5:3 (1 cement 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size de rived from natural sources)

59.1

-

-

... More
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stane aggregate 20 mm nominal size derived from natural sources).

12.26

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases. above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).

78.17

-

-

... More
4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources).

35.7

-

-

... More
SHUTTERING & FORMWORK: 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.

124.2

-

-

... More
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers

365.14

-

-

... More
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts

241.99

-

-

... More
5.9.3 Suspended floors, roofs, landings, balconies and access platform

419.73

-

-

... More
5.9.7 Stairs, (excluding landings) except spiral-staircases

19.31

-

-

... More
PRE CONSTRUCTION ANTI- TERMITE TREATMENT: Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion): Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

440.55

-

-

... More
BRICK WORK: 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of 16.12.1 class designation 7.5

440.55

-

-

... More
6.2. Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

20.93

-

-

... More
6.13. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)

460.9

-

-

... More
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.2 Sal wood.

2.73

-

-

... More
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in- charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters

62.01

-

-

... More
PVC DOOR FRAME : 9.145 Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineerin-charge.

19.8

-

-

... More
9.144 Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of tyle by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer's specification and direction of Engineer-in-charge.

5.33

-

-

... More
Tiles WORKS: 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41 Size of Tile 600X600 mm

359.78

-

-

... More
PLASTERING WORKS: 13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)

396.92

-

-

... More
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1 1:4 (1 cement: 4 fine sand)

606.8

-

-

... More
13.3 20 mm cement plaster of mix: 13.3.1 1:4 (1 cement: 4 fine sand)

673.22

-

-

... More
GRILL WORKS: 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding.

530.4

-

-

... More
PLINTH PROTECTION : 4.17 Making plinth protection 50mm thick of cement. concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.

43.5

-

-

... More
PAINTING 13.50.1 With ready mixed pink or Grey primer of approved brand.

58.44

-

-

... More
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.

58.44

-

-

... More
13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.

35.36

-

-

... More
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 tr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and…..

35.36

-

-

... More
13.26 Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.

1610.51

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer

1610.51

-

-

... More
13.48A Finishing walls walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

1610.51

-

-

... More
DOOR WINDOW FITTINGS: 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 9.96.1 300mm x 16mm

11

-

-

... More
9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.97.1 300mm x 10mm

74

-

-

... More
9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.100.1 125mm

74

-

-

... More
9.107 Providing and fixing PTMT Butt hinges with necessary screws etc. complete. 9.107.1 75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 34 gms

132

-

-

... More
Sanitary Installation & Water Supply works 17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistem with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres). including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

2

-

-

... More
17.4 Providing and fixing white vitreous china flat back or wall comer type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.4.2 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern.

3

-

-

... More
17.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required: 17.6.2 Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern.

2

-

-

... More
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever. 17.7.8 White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers.

4

-

-

... More
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.1 Semi rigid pipe 17.28.1. 40 mm dia

4

-

-

... More
17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

3

-

-

... More
17.34 Providing and fixing toilet paper holder: 17.34.2 Vitreous china

2

-

-

... More
17.35 Providing and fixing soil, waste and vent pipes: 17.35.1 100 mm dia 17.35.1. Sand cast iron S&S pipe as per IS. 1729

6

-

-

... More
17.60 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 17.60.1 100 mm inlet and 100 mm outlet 17.60.1. Sand cast iron S&S as per IS: 3989

4

-

-

... More
17.61 Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement: 3 coarse sand 6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement: 4 17.61.1 100 mm dia

10

-

-

... More
17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

4

-

-

... More
17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

4

-

-

... More
18.15 Providing and fixing brass bib cock of approved quality: 18.15.2 20 mm nominal bor

8

-

-

... More
18.16 Providing and fixing brass stop cock of approved quality: 18.16.2 20 mm nominal bor

8

-

-

... More
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.1 15 mm dia nominal outer dia pipes.

35

-

-

... More
18.9.2. 20 mm dia nominal outer dia pipes.

30

-

-

... More
18.9.3 25 mm dia nominal outer dia pipes

25

-

-

... More
18.9.4 32 mm dia nominal outer dia pipes

22

-

-

... More
18.9.5 40 mm dia nominal outer dia pipes

18

-

-

... More
18.9.6 50 mm dia nominal outer dia pipes

15

-

-

... More
18.10 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 18.10.1 15 mm dia nominal bore

15.15

-

-

... More
18.12 Providing and fixing G.I. pipes complete with G.I. fittings Internal work - Exposed on wall 18.12.2 20 mm dia nominal bore.

20

-

-

... More
18.12.4 32 mm dia nominal bore metre.

18

-

-

... More
18.12.5 40 mm dia nominal bore.

15

-

-

... More
18.13 Providing and fixing gun metal non- return valve of approved quality (screwed end): 18.13.1 20 to 40 mm nominal bore.

5

-

-

... More
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 18.17.1A 20 mm nominal bore

4

-

-

... More
18.17.2 32 mm nominal bore

5

-

-

... More
18.17.3 40 mm nominal bore

3

-

-

... More
18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end): 18.19.340 mm nominal bore 18.19.3. Horizontal.

2

-

-

... More
18.19.3. Vertical.

3

-

-

... More
18.21 Providing and fixing uplasticised PVC connection pipe with brass unions: 18.21.1 30 cm length 18.21.1 15 mm nominal bore

10

-

-

... More
18.21.2 20 mm nominal bore

13

-

-

... More
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

6000

-

-

... More
18.42 Boring with 100 mm diameter casing pipe for hand pump /tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump/tube well is lowered and tested: 18.42.1 Up to 6 metres depth.

6

-

-

... More
18.42.2 Beyond 6 m and up to 12 m depth

6

-

-

... More
18.42.3 Beyond 12 m and up to required depth

17

-

-

... More
18.43 Providing and placing in position filters of 40mm diameter G.I. pipe with brass strainer of approved quality.

3

-

-

... More
18.45 Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories.

1

-

-

... More
18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 8.46.6 50 mm nominal bore.

1

-

-

... More
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 9.4.2 150 x 100 mm size P type. 19.4.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Reducing Socket, bend, tee, etc.

1

-

-

... More
SEPTIC TANK 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.

16.58

-

-

... More
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

1.07

-

-

... More
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).

1.07

-

-

... More
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or morE.

135.31

-

-

... More
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.

3.37

-

-

... More
5.9.3 Suspended floors, roofs, landings, balconies and access platform.

6.33

-

-

... More
5.9.13 Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.

1.8

-

-

... More
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size de rived from natural sources) Tank Bottom Slab:

1.99

-

-

... More
6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

5.7

-

-

... More
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 13.2 Cement mortar 1:4 (1 cement :4 coarse sand)

4.18

-

-

... More
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand).

40.22

-

-

... More
11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick

40.22

-

-

... More
ELECTRICAL WORK 1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface recessed medium class PVC condult, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. a) Group A

86

-

-

... More
1.2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

25

-

-

... More
1.3 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

75

-

-

... More
1.4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.

65

-

-

... More
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

60

-

-

... More
c) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire

72

-

-

... More
1.5 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm

70

-

-

... More
b) 6 x 1.5 sq. mm

68

-

-

... More
c) 6 x 4 sq. mm

72

-

-

... More
1.6 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm

66

-

-

... More
1.6 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm

61

-

-

... More
1.8 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

8

-

-

... More
1.9 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

6

-

-

... More
1.12 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required, (a) 25 A socket outlet.

130

-

-

... More
(b) 25 A motor starter

1

-

-

... More
Sub Head-II (MCB & DB'S) 2.1 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way, Double door.

4

-

-

... More
2.2 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 215 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator) a) 4 way (4+12), Double door

4

-

-

... More
b) 8 way (4+24), Double door

6

-

-

... More
2.3 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a)12 way (4+ 36), Double door.

5

-

-

... More
2.4 Supplying and fixing 5 amps to 32 amps rating. 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole

12

-

-

... More
2.5 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 amps

4

-

-

... More
2.6 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 amps

6

-

-

... More
2.7 Supplying and fixing following rating and breaking capacity MCCB in existing vertical TPN DB/Panel board including connection testing, etc. complete as required. 2.8 Supplying and fixing following rating, 415 V, 10 kA. "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. (a) 40/63 A TP

4

-

-

... More
Sub Head-ll (FAN,FITTINGS AND FIXTURES) 3.2 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

26

-

-

... More
3.3 Supplying, of 1200 mm sweep, BEE five star rated, ceiling fan with Brush Less Direct Current (BLDC motor) not less than 32 W, class of insulation B, 3 Nos blade, 30 cm long down road, 2 Nos of canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMMW) minimum 6.85 air delivery minimum 215cmm, 350 rpm (Tolerance as per IS:374- 2019), THD less than 10% remote or electronic regulator for speed control and all remaining accessories i/c safety pin, nut bolts, washer, temperature rise=75 degree C(max.), insulation resistance more than 2mega ohm, suitable for 230V, 50 Hz AC supply, earthing etc. complete as required.

26

-

-

... More
3.4 Supplying of 250/260 mm sweep Fresh Air fan(PVC body) in the existing opening i/c making the hole to suite the size of the above fan, making good the damage, connection, connection, testing & commissioning etc, as reqd.

4

-

-

... More
3.7 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) Upto 450 mm sweep

4

-

-

... More
3.10 Supplying, Installation, Testing and Commissioning of Fancy Wall bracket fitting with 9 watt retrofit LED lamp including earthing connection etc. Complete as required.

10

-

-

... More
3.11 Supplying, Installation, testing and commissioning of surface mounted square/round shape LED downlighter having suitable housing Lumen efficacy 100lm/watt, System Lumen output z 1200 Im, CRI ≥ 80, Power factor ≥ 0.9 having suitable diffuser and CCT in between 4000K to 6500 K (i/c both Limits) complete with all accessories etc. directly on ceiling/wall including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

136

-

-

... More
Sub Head-IV (Service Connection) 4.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm

75

-

-

... More
b) Above 35 sq. mm and upto 95 sq, mm.

78

-

-

... More
4.2 Supplying of one number XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade with ISI marked (IS 7098 (Part-1)/1988 with amendment up to date) following sizes. a) 3.5 X 35 sq.mm

65

-

-

... More
b) 3.5 X 95 Sq.mm

61

-

-

... More
4.3 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade las required. a) 3.5 x 35 sqmm (32 mm)

12

-

-

... More
b) 3.5 X 95 Sq.mm (45 mm)

10

-

-

... More
4.4 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal).

37

-

-

... More
4.5 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. a) 80 mm dia

45

-

-

... More
4.6 Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.

4

-

-

... More
SUB-HEAD-VI Lighting Conductor and earthing 5.1 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

3

-

-

... More
5.2 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

25

-

-

... More
5.3 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run).

38

-

-

... More
5.4 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

3

-

-

... More
5.6 Earthing with G.1. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

-

-

... More
5.7 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

21

-

-

... More
5.8 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

28.04

-

-

... More
5.9 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

26

-

-

... More
5.10 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

23

-

-

... More
HORTICULTURE WORK Providing and stacking of Azadirachta indica (Neem) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.

20

-

-

... More
7.51 Providing and stacking of Lagerstroemia thorelli of height 150-165 cm.in big poly bag of size 25 cm as per direction of the officer-in-charge.

20

-

-

... More
Providing and stacking of Jacaranda mimosifolia of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

11

-

-

... More
Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge.

12

-

-

... More
Providing and stacking of Polyalthia longifolia (Ashok) of height 150-165 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.

11

-

-

... More
Providing and stacking of Tectona grandis (Teak) of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.

11

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20%: 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, H) with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 2.14.1 Holes 1.2 m dia and 1.2 m deep

41

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.