Bodoland Territorial Council Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Bodoland Territorial Council - BTC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date25 Nov 2024
Closing Date16 Dec 2024
Tender Amount₹ 6,86,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

0.06

-

-

... More
5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)

115.24

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

3.11

-

-

... More
5.33A Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 5.33A.1 All works upto plinth level 5.33A.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum

283.08

-

-

... More
5.33A.2 All works above plinth level up to floor V level 5.33A.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum

464.53

-

-

... More
11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate

1942

-

-

... More
5.9 Centering and shuttering including strutting, propping etc. and removal of form work for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete

430.91

-

-

... More
5.9.3 Suspended floors, roofs, landings, balconies and acces platform

2224.29

-

-

... More
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers

1147.72

-

-

... More
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.

1388.58

-

-

... More
5.9.7 Stairs, (excluding landings) except spiral-staircases

47.25

-

-

... More
11.1 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 11.1.2 1:6 (1cement : 6 coarse sand)

892.2

-

-

... More
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

19.42

-

-

... More
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)

227.52

-

-

... More
6.12 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : 6.12.2 Cement mortar 1:4 (1 cement : 4 coarse sand)

78.62

-

-

... More
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand)

5045.33

-

-

... More
6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

5045.33

-

-

... More
8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.2 Granite stone slab colour black, Cherry/Ruby red. Area of slab over 0.50 sqm

5.06

-

-

... More
8.3 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 8.3.2 Granite work

8.43

-

-

... More
8.4 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.

8.43

-

-

... More
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

1039.24

-

-

... More
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) 9.1.1 Second class teak wood

12.94

-

-

... More
9.20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

263.03

-

-

... More
9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

263.03

-

-

... More
9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).

263.03

-

-

... More
9.4 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 9.40.1 2nd class teak wood 9.40.1.2 50 x 20 mm

681.4

-

-

... More
9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)

796

-

-

... More
9.62 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm

138

-

-

... More
9.92 Providing and fixing chromium plated brass handles with necessary screws etc. complete: 125 mm

138

-

-

... More
9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm

138

-

-

... More
9.101 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper

138

-

-

... More
21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all mplete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade ccording to IS: 1868, Minimum anodic coating of grade AC 15)

1713.6

-

-

... More
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc . complete as per the architectural drawings and the directions of engineer-in-charge . Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)

287.25

-

-

... More
10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

3013.5

-

-

... More
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6A Thermo-Mechanically Treated bars of grade Fe-500D or more.

84467.26

-

-

... More
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm

2410.37

-

-

... More
11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles ently and easily. 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size. 11.41A.3.1 Size of Tile 600 x 600 mm

505.72

-

-

... More
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)

1053.24

-

-

... More
12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board

158.8

-

-

... More
13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)

5032.2

-

-

... More
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix. 13.2.1 1:4 (1 cement: 4 fine sand).

5175.96

-

-

... More
13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

506.91

-

-

... More
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer. Quote for each layer over the plastered wall surface to prepare the surface even and smooth complete.

5032.2

-

-

... More
13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

5175.96

-

-

... More
13.37 White washing with lime to give an even shade : 13.37.1 New work (three or more coats)

2807.76

-

-

... More
13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

5032.2

-

-

... More
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.9 100 mm nominal dia Pipes

30

-

-

... More
19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. 19.19.1 L D- 2.5 19.19.1.3 Circular shape 450 mm internal diameter

8

-

-

... More
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²

759.72

-

-

... More
10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

37745

-

-

... More
22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)

378.19

-

-

... More
22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

509.4

-

-

... More
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.

4

-

-

... More
17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid

37

-

-

... More
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

37

-

-

... More
18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 18.51.1 15 mm nominal bore

62

-

-

... More
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.4 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

39

-

-

... More
17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

39

-

-

... More
17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern

35

-

-

... More
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.3 40 mm nominal bore

40

-

-

... More
18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore

32

-

-

... More
17.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.2 Rectangular shape 453x357 mm

39

-

-

... More
18.65 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms.

76

-

-

... More
17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

62

-

-

... More
18.58 Providing and fixing PTMT grating of approved quality and colour. 18.58.1 Circular type 18.58.1.1 100 mm nominal dia

76

-

-

... More
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 18.7.3 40 mm nominal dia. Pipes.

160

-

-

... More
18.7.5 25 mm nominal dia .Pipes.

210

-

-

... More
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. : Concealed work, including cutting chases and making good the walls etc. and sizes in: 18.8.1 15 mm nominal dia Pipes

270

-

-

... More
12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.1 75 mm diameter

120

-

-

... More
12.42.5 Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Bend 87.5° 12.42.5.1 75 mm bend

20

-

-

... More
12.42.6 Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Shoe Plain 12.42.6.1 75 mm shoe

31

-

-

... More
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

10000

-

-

... More
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches 75mm dia

180

-

-

... More
110mm dia

150

-

-

... More
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75mm dia

120

-

-

... More
110mm dia

100

-

-

... More
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches 75mm dia

25

-

-

... More
110mm dia

25

-

-

... More
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75mm dia

30

-

-

... More
110mm dia

30

-

-

... More
Supplying, fitting and fixing 87.5 degree PVC bend with a door of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches 75mm dia

30

-

-

... More
110mm dia

30

-

-

... More
Supplying, fitting and fixing 87.5 degree PVC bend with a door of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75mm dia

25

-

-

... More
110mm dia

25

-

-

... More
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches 75mm dia

20

-

-

... More
110mm dia

20

-

-

... More
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75mm dia

30

-

-

... More
110mm dia

30

-

-

... More
Supplying fiting and fixing PVC Plain single tee with a door of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches 75mm dia

25

-

-

... More
110mm dia

25

-

-

... More
Supplying fiting and fixing PVC Plain single tee with a door of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75mm dia

30

-

-

... More
110mm dia

30

-

-

... More
Supplying fiting and fixing PVC cross ‘T’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches 75mm dia

35

-

-

... More
110mm dia

35

-

-

... More
Supplying fiting and fixing PVC cross ‘T’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75mm dia

30

-

-

... More
110mm dia

30

-

-

... More
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches 75mm dia

35

-

-

... More
110mm dia

35

-

-

... More
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75mm dia

25

-

-

... More
110mm dia

25

-

-

... More
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. 75mm dia

25

-

-

... More
110mm dia

60

-

-

... More
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. 90mm dia. PVC Cowel of ISI Make

90

-

-

... More
23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 23.3.1 100 mm nominal size dia

67

-

-

... More
23.3.2 150 mm nominal size dia

3

-

-

... More
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (SUCTION PIPE) External work 18.9.5 40 mm nominal outer dia Pipes

70

-

-

... More
18.43 Providing and placing in position filters of 40 mm diameter G.I./ PVC pipe with brass strainer of approved quality.

25

-

-

... More
18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.19.3 40 mm nominal bore Horizontal

1

-

-

... More
18.19.3.2 Vertical

1

-

-

... More
23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

6

-

-

... More
23.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 23.13.1 100 mm dia

1

-

-

... More
23.13.2 150 mm dia

1

-

-

... More
23.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 23.14.2 150 mm clamp

3

-

-

... More
23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the 23.15.1 100 mm dia

1

-

-

... More
23.15.2 150 mm dia.

3

-

-

... More
23.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

2

-

-

... More
Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).

70

-

-

... More
Machine boring of deep tube well upto 150 mm dia. Bore hole as directed by the Engineer in Charge

70

-

-

... More
Motor Pump Set Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 1 HP STAGE 5 to 18 with MCB controlled Submersible motor pump set control panel.

1

-

-

... More
Supplying including installation, connection as approved by the Deptt., testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt. 1 HP single Phase jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .

1

-

-

... More
1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B

750

-

-

... More
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

1700

-

-

... More
1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1100

-

-

... More
1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

656

-

-

... More
1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1.22.8 200 mm X 150 mm X 75 mm deep

123

-

-

... More
1.22.6 200 mm X 125 mm X 60 mm deep

150

-

-

... More
1.22.3 150 mm X 75 mm X 60 mm deep

141

-

-

... More
1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.6 12 Module

60

-

-

... More
1.28.4 6 Module

60

-

-

... More
1.28.3 4 Module

70

-

-

... More
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch

160

-

-

... More
1.24.4 3 pin 5/6 A socket outlet

160

-

-

... More
1.24.3 15/16 A switch

60

-

-

... More
1.24.5 6 pin 15/16 A socket outlet

60

-

-

... More
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1 4 way (4 + 12), Double door

10

-

-

... More
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.4 Triple Pole

142

-

-

... More
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

3

-

-

... More
5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re- filling etc. as required.

60

-

-

... More
7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 Upto 35 sq. Mm

920

-

-

... More
7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle)

800

-

-

... More
1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

100

-

-

... More
1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

118

-

-

... More
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

119

-

-

... More
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENT make)

46

-

-

... More
Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. Sleek and compact T-8 in plastic batten luminaries complete with Electronic ballast with 1 X 36 watt Fluorescent tube.(Crompton Greaves make) Model- T8 L036 EB X-LITE with Power Lux Lamp/ L036 EBR X- LITE with Super Saver Lamp/ L036 EBR X-LITE with Power Lux Lamp or equivalent (Equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make).

140

-

-

... More
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS- 390 Deco Havells make)

118

-

-

... More
Supplying with fitting fixing of following Clean room luminaries of CFL either surface mounting or recessed mounted as specified and directed by the department. FCS 650 3 X PL-L 36 W EBP FOP GT Phillips make) CLARIA suitable for 3 x 36 PL-L lamps available in bottom opening options and also with toughened glass ( IP 65 from front ) clear acrylic versions( IP 54 from front) .or equivalent (Equivalent will be selected by the deptt considering the mother items rate) WIPRO/ JAQUAR make.

30

-

-

... More
Supply, installation, testing and commissioning of 11 KV Non Walk-in Type Outdoor type Package substation (100 KVA) with internal lighting, earthing, padlocks etc. connection between RMU and transformer with busbars, between transformer and LT breaker etc. and with the following:- 2 way Non-extensible unit with 1 nos. . Isolators / load breaking switches as incomers and 1 no. Vaccum circuit breaker as outgoing to the transformer with the following accessories:- IDMT relays for circuit creakers. SF6 Gas Pressure Indicator Padlocking facility 100 KVA Oil Cooled Transformer with copper windings and standard fittings and -5 to +5 % in steps of 2.5 % (4 steps, 5 Position) ON Load Tap Changer, 11 KV/433 V. 3 phase, 50 Hz, Vector Group Dyn-1 1 with all fittings and accessories, filtered oil, including bucholtz relay, Winding Temperature Indicator, Oil Temperature Indicator, Magnetic Oil GauQe etc. 250 Amp. Three Pole Manually operated MCCB (35 KA) with static release and with standard protection devices with provision for cable termination as required.

1

-

-

... More
2.1 Supply of following 11 KV grade multicore Aluminium conductor XLPE insulated cable, insulation screening with extruded semi conducting compound in combination with copper tape (0.3kA for 1 Sec., cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS : 7098 (Part - II) and complete with all latest amendments etc. complete as required 3 C x 35 Sq. mm

20

-

-

... More
Laying of one number XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of size not exceeding 50 Sq.mm in the existing masonary open duct as required.

20

-

-

... More
3.2.1 Supply & making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for the following sizes of 3 core, XLPE aluminium conductor cable of 1] KV grade as required. 3 C x 5 Sq.mm

2

-

-

... More
4.1 Supply, installation, testing and commissioning of LT Panel Boards of 2 mm thick sheet steel cubicle design for Indoor mounting factory fabricated suitable for operation on 440 V 3 phase, 50 Hz, A.C. supply with MCCBs/ DP MCB/Four Pole MCB and other accessories, all in compartmentalised, cubicle construction complete in all respects including internal wiring, labels, ferrules, cable termination gland plates, earth terminals, painting etc. conforming to specifications. All MCCB shall be with Rotary handle. There shall be locking and sealing arrangement for all the compartments of the panels / Incomer / Bus Bar Chamber. Main Panel - Incoming: One (1) No. 250 A TPN MCCB (25 KA). One (1) No. 150 A TPN MCCB (25 KA). Bus Bar: 400 A TPN Aluminium Bus bar with colour coded heat shrinkable PVC sleeves. Outgoings Comprising of: Five (5) Nos.63 A TPN MCCB (25 KA). Three (3) Nos.40 A TPN MCCB (25 KA). Six (6) Nos. 32 A DP MCB (10 KA)

1

-

-

... More
5.1 Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 complete with all amendments etc. as required. 4 C x 10 Sq.mm

60

-

-

... More
4 C x 16 Sq.mm

100

-

-

... More
4 C x 35 Sq.min

300

-

-

... More
3.5 C x 70 Sq.mm

50

-

-

... More
3.5 C x 120 Sq.mm

40

-

-

... More
6.1 Laying of one number PVC insulated and PVC sheathed /XLPE power cable 1.1 KV grade of following sizes direct in ground including excavation, sand cushoning protective covering and refilling the trench etc. as required:- Upto 35 sq. Mm

460

-

-

... More
35 sq. to 120 sq. mm

90

-

-

... More
7.2.1 Supply and making end termination with brass compression glands and aluminium lugs for PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade of the following sizes as required:- 4 C x 10 Sq.mm

10

-

-

... More
4 C x 16 Sq.mm

10

-

-

... More
4 C x 35 Sq.mm

10

-

-

... More
3.5 C x 50 Sq.mm

10

-

-

... More
3.5 C x 70 Sq.mm

4

-

-

... More
3.5 C x 120 Sq.mm

2

-

-

... More
2.28 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 2.28.1 All kinds of Soil

4000

-

-

... More
Raising low site with approved soil obtained from outside by truck carriage including breaking clods, dressing compacting etc. complete including paying necessary land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity etc. complete as directed and specified, including forest royality. (Forest royality shall be reimbrushed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned). Other than Guwahati City

1200

-

-

... More
4.1 (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material

40

-

-

... More
2) WBM Grading II 4.7 Using stone screening Type-B 11.2 mm for Gr.II Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. (A) By Manual Means

30

-

-

... More
(A) Interlocking pavement block (i) Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage. (a) Including Edge block/ Edge restraints

400

-

-

... More
2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 2.6.1 All kinds of soil

237.65

-

-

... More
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

189.57

-

-

... More
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.6 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)

24.11

-

-

... More
4.1 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate (12.5mm nominal size).

107.66

-

-

... More
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

27.27

-

-

... More
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :

4.13

-

-

... More
17.8 Supplying, fitting and fixing goat proof wire fencing 1070mm high with horizontal wire spacing at 130 mm, 130mm, 150mm, 150mm, 180mm and 180mm from bottom onwards and vertical wires at 100mm apart top and bottom wires should be of 8 S.W G. and intermediate and vertical wire should be of 10S.W.G.with angle iron posts specified in item no 17.7 above including supplying, fitting and fixing with necessary straining eye bolts and staples etc. and painting one coat to all iron posts etc. with anti-corrosive black paint etc. complete as directed and specified(intermediate and straining post should be placed not more than 4000mm and not less than 3000 mm apart and all posts embedded in C.C. pillars of size 300mm x 300mm x 600mm in prop 1:3:6).

469.8

-

-

... More
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete

42.28

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

239.25

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

105.6

-

-

... More
11.1 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 11.1.2 1:6 (1cement : 6 coarse sand)

118.24

-

-

... More
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

35.89

-

-

... More
6.13 Half Brick masonary with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor level V 6.13 .1 Cement mortar 1:3 (1 cement : 3 coarse sand)

179.44

-

-

... More
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand)

195.75

-

-

... More
13.1 12 mm cement plaster of mix : 13.1 .1 1:4 (1 cement: 4 fine sand)

495.57

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

691.32

-

-

... More
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade: 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).

691.32

-

-

... More
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

3768

-

-

... More
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.3 Electric resistance or induction butt welded tubes

737.31

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.