Tirumala Tirupati Devasthanams Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Tirumala Tirupati Devasthanams Tender
Opening Date18 Sep 2021
Closing Date4 Oct 2021
Tender Amount₹ 33,20,334 This is an estimated amount, exact amount may vary.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
444741Bid Award Id
ViewTender No
201/DE-II/(Elec.)/TTD/TPT/2021-22Tender Authority
Tirumala Tirupati Devasthanams ViewPurchaser Address
-Website
http://tender.apeprocurement.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SITC of (30 plus 30) KVA parallel UPS;Supply and Fixing of 125A 3 Pole MCCB, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25KA, with thermal magnetic release in the existing board including internal connections and Labour charges etc., complete. Grade-A: Makes: Legrand DPX3 / Schneider- Acti9 / Hager - Novello+ / Seimens / Havells STADx / L&T- Newrang / Indoasian (Opti pro).
2
-
17184.2
SITC of (30 plus 30) KVA parallel UPS;Supply of 16 Sq.mm 4 Core LT PVC Flexible, insulated and sheathed FRLS copper round cable for voltage up to 1100V as per IS 694/1990. Make: Finolex / Havells / Polycab / Gloster / KEI / RR Kabel.
100
-
61784
SITC of (30 plus 30) KVA parallel UPS;Supply of Single Core 25 Sqmm PVC insulated and sheathed FRLS copper round cable for voltage up to 1100V as per IS694/1990. Makes: V-Guard/Bonton /Finecab/ HPL / Million / Fortune Art/ Sudhakar/ Orbit/ Tamra/ Anchor/Plaza/Vihan/Spykaar/Ollvin/Laser/Beljin/ Rhino/ Standard/ Vimal
600
-
132636
SITC of (30 plus 30) KVA parallel UPS;Supply Installation Testing and commissioning of free standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be abricated from CPRI approved fabricator).
7.2
-
34689.67
SITC of (30 plus 30) KVA parallel UPS;Supply and fixing of 1 No of 200 Amp F.P. Changeover switch (ON-LOAD) as per IS:13947 open type with all accessories etc., complete In existing Panel Board. Grade-A: Make: L&T / Havells / Standard / Indo Asian / C&S / Socomec
1
-
12407.8
SITC of (30 plus 30) KVA parallel UPS;Supply and fixing of 4 Way VTPN D.Bs suitable for accommodating 125A / 160A 4 Pole MCCB as incomer and TP/SP MCBs as outgoing with IP-43 protection as per IS 8623; IS 13032; IEC 61439-3. (Metal door) firmly on the surface of the wall etc., complete. [Excluding Incomer & Outgoings] Grade-A: Make: Legrand (Ekinox 3) / Schneider-Acti9 / Hager - Novello+ / Seimens / Havells STADx / L&T-Newrang / Indoasian (Opti Pro)
1
-
10505.84
SITC of (30 plus 30) KVA parallel UPS;Supply of parallel maintenance bypass panel suitable for up to four units for capacity or redundancy for 20 KVA / 30 KVA UPS, 400V wall mount type.
1
-
49500
SITC of (30 plus 30) KVA parallel UPS;Supply of Parallel Communication kit in built in UPS / External with following features. The Ethernet Web/SNMP Adaptor shall allow one or more network management systems (NMS) to monitor and manage the UPS in TCP/IP network environments. The management information base (MIB) shall be provided in DOS and UNIX "tar" formats. The SNMP interface adaptor shall be connected to the UPS via the RS232 serial port on the standard communication interface board The UPS, in conjunction with a network interface card, shall be capable of gracefully shutting down one or more operating systems during when the UPS is on reserve mode. The UPS shall also be capable of using an RS232 port to communicate by means of serial communications to gracefully shut down one or more operating systems during on battery situation. Web Monitoring: Remote monitoring shall be available via a web browser such as Internet Explorer. RS232 Monitoring: Remote UPS monitoring shall be possible via either RS232 or contact closure signals from the UPS. Simple Network Management Protocol (SNMP): Remote UPS Monitoring shall be possible through a standard MIB II compliant platform. Make: Schneider / Emerson / Socomec
1
-
18000
SITC of (30 plus 30) KVA parallel UPS;Supply and fixing of 8 Way VTPN D.Bs suitable for accomodating 125A / 160A 4 Pole MCCB as incomer and TP/SP MCBs as outgoing with IP-43 protection as per IS 8623; IS 13032; IEC 61439-3. (Metal door) firmly on the surface of the wall etc., complete. [Excluding Incomer & Outgoings] Grade-A: Make: Legrand (Ekinox 3) / Schneider-Acti9 / Hager - Novello+ / Seimens / Havells STADx / L&T-Newrang / Indoasian (Opti Pro)
1
-
13124.57
SITC of (30 plus 30) KVA parallel UPS;Supply and fixing of 40 to 63 Amp TP MCBs 10 KA breaking capacity 'C'/ 'D' Curve ISI Mark as per IS:60898-1:2002 in the existing board and giving necessary connections. Grade-A: Makes: Legrand DX3 / Schneider- Acti9 / Hager - Novello+ / Seimens / Havells STADx / L&T- Newrang / Indoasian (Opti pro).
8
-
14049.52
SITC of (30 plus 30) KVA parallel UPS;Supply and transportation of 150 Sq.mm 3 1/2 core LT XLPE insulated, 1100V grade armoured Aluminium UG cable as per specification confirming to IS:7098 (Part-I) / 1554-1. Grade-A: Make: Torent / Universal / Unistar / Havells / KEI / Gloster / Polycab / RR Kabel / Finolex.
160
-
137851.2
SITC of (30 plus 30) KVA parallel UPS;Supply and transportation of 300 Sq.mm 3 1/2 core LT XLPE insulated, 1100V grade armoured Aluminium UG cable as per specification confirming to IS:7098 (Part-I) / 1554-1. Grade-A: Make: Torent / Universal / Unistar / Havells / KEI / Gloster / Polycab / RR Kabel / Finolex.
160
-
261193.6
SITC of (30 plus 30) KVA parallel UPS;Laying of U.G cables size from 70 Sq.mm to 150 sq.mm and back filling of trench including labour charges etc., complete.
60
-
3408
SITC of (30 plus 30) KVA parallel UPS;Laying of U.G cables size from 185 Sq.mm to 400 sq.mm and back filling of trench including labour charges etc., complete.
60
-
4039.2
SITC of (30 plus 30) KVA parallel UPS;Labour charges for run of U.G.Cable from 70 sq.mm to 150Sq.mm on wall through existing (PVC / G.I) pipe with necessary fixing arrangements such as saddles, clamps, wooden separator etc., if any with necessary connections (as directed by departmental official).
100
-
8932
SITC of (30 plus 30) KVA parallel UPS;Labour charges for run of U.G.Cable from 185 sq.mm to 400Sq.mm on wall through existing (PVC / G.I) pipe with necessary fixing arrangements such as saddles, clamps, wooden separator etc., if any with necessary connections (as directed by departmental official).
100
-
11117
SITC of (30 plus 30) KVA parallel UPS;Supply and making one end termination with heavy duty single compression brass gland as per BS 6121:2005, IP 66 complete, SIBG type, heavy duty Alluminium lugs duly crimped with crimping tool, PVC tape etc for 150 Sq.mm with brass washers of Armoured PVC insulated & PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade as required of size. Make: Dowels / Comet / SMI
6
-
3060.84
SITC of (30 plus 30) KVA parallel UPS;Supply and making one end termination with heavy duty single compression brass gland as per BS 6121:2005, IP 66 complete, SIBGtype, heavy duty Alluminium lugs duly crimped with crimping tool, PVC tape etc for 300 Sq.mm with brass washers of Armoured PVC insulated & PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade as required of size. Make: Dowels / Comet / SMI
2
-
2040.58
SITC of (30 plus 30) KVA parallel UPS;Supply and fixing of fabricated M.S clamps made out of 25mm x 6mm MS flat with necessary holes on either side with suitable 2" coach screws and painting 2 coats of enamel black paint over one coat of red oxide suitable for fixing of UG Cables of size 150 Sq.mm to 240 Sq.mm on walls etc., including all labour charges etc., complete.
200
-
17324
SITC of (30 plus 30) KVA parallel UPS;Supply and fixing of fabricated M.S clamps made out of 25mm x 6mm MS flat with necessary holes on either side with suitable 2" coach screws and painting 2 coats of enamel black paint over one coat of red oxide suitable for fixing of UG Cables of size 300 Sq.mm on walls etc., including all labour charges etc., complete.
200
-
19770
SITC of (30 plus 30) KVA parallel UPS;Providing of Independent Earthing as per IS 3043 of 1987 with Copper Plate of 600 mm X 600 mm X 3.15 mm thick of Electrolytic grade burried the top of the plate below 2 M from ground level after excavating an Earth pit of 1.5 x 0.9 x 2.55 m (Top 1.50m X 0.90m X 0.90m) and Bottom (1.20mX 0.90m X1.65 m) rigidly fixed to 40 mm dia GI pipe of 2 m long with 3 Nos. of 25 mm X 6 mm Clamps with suitable bolts, & nuts. 2 Nos. of 25 mm X 6 mm Copper Flats of 2 M long are to be fixed with brass bolts & nuts and brazed at bottom side to the copper plate on either side of the GI pipe. A concrete bed of size 0.8 M X 0.8 M X 0.10 M thick and an inspection chamber having inside measurements of 0.4m X0.4 m X 0.4 m with wall thickness of 100 mm with cement concrete CC (1:2.5:5) using 20 mm HBG Metal is to be constructed with side wall 100 mm above ground level and plastering the exposed walls neatly with CM (1:3) with 12 mm thick. The Top of the inspection chamber is to be provided with reinforced precasted RCC slab with 40 mm thick with lifiting hook. The top of the 40 mm dia GI pipe is welded with reducer and 0.3 M, 20 mm dia GI pipe. the top of the 20 mm GI pipe is to be fixed with funned & wiremesh. The top of the 25 X 6 mm copper flats are to be fixed with brass bolts, nuts, washers & brazed with 0.2 M of 50 X 6 mm copper flat across and the same is to be fixed with suitable GI strip to the 40 mm GI pipe. The Entire set is to be placed in the Earth pit, the mixture of 40 Kgs of Hardcoke / charcoal, 20 Kgs of salt, & sand is spread around the copper plate and around to the 40 mm GI pipe and the remaining is to be back filled. consilidation / settlement of filled eath pit is to be done by filling water. After giving earth connections to the 50 X 6 mm copper flat with brass bolts, nuts & washers. A pre- casted RCC slab cover with 50 mm thick with lifting hook is to be provided on top of the Earth pit. The rate includes cost and conveyance of all materials, labour charges, incidental charges etc., complete. (Note: Necessary meggaring testing is to be done in the presence of the concerned Engineers, and the reading should be as per IE standards)
2
-
34853.58
SITC of (30 plus 30) KVA parallel UPS;Supply and run of 25mm X 6mm Copper Strip for earth electrode to required places by Surface in walls, flooring including cost of all accessories and giving necessary connection with 3/8"x2" Brass Bolts, Nuts and Washers wherever joints has to be done. The strip has to be either riveted (or) bolted (or) gas welding neatly and all labour charges etc., complete.
150
-
152277
SITC of (30 plus 30) KVA parallel UPS;Design, fabrication, supply and errection of L.T indoor type cubical Lightning panel board made with 14 SWG CRCA sheet. The size of panel should be 1600(w)mm x 2000(H)mm x 600(D)mm should be mounted on suitable base MS channel and fixing firmly as directed execution. The following switch gears, bus bars etc. should be supply and fixing in the panel firmly, and the panel with necessary individual doors, separate chambers for bus bars, out going cables etc. All the doors shall be provided with rubber beading and door knobs. The Top of the box should have provision for Incoming and Outgoing cables / Wire, The entire panel should be powder coated with siemens grey color through 7 tank process. Incoming:- 1) 1 No. of Supply of 400A 3 Pole MCCB, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 36/35KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider-NS NSX/ Legrand -DPX3/ Siemens-3VL / Hager-h3/C&S -Winbreak2 Outgoing:- 1) 4 Nos of 125A 3 Pole MCCB, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider-NS NSX/Legrand -DPX3/ Siemens-3VL / Hager- h3/C&S -Winbreak2Makes: GE / ABB / Havells / HPL / Standard / Indo Asian. Metering:- 1) Supply and Fixing of energy analyser (multy function energy meter) with LCD/LED display capable of minimum 20 numbers electrical parameters display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc.c, omplete in all respect - 1No. 2) Supply and Fixing of 240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required - 1Set Copper Bus bar arrangement:- 1) The size of copper flat 50mm x 6mm shall be run from 400A MCCB unit to vertical bus bar chamberwith 400x12x50mm insulators supports and shall be run vertically and horrizontally in Bus bar chamber fix the bus bar with necessary insulators supports. 2) The size of copper flat 25mm x 6mm shall be provided to 125Amps MCCB connect to main bus bar and provide extension bits at out going side for cable connection with necessary bolts and nuts and using necessary 40x8mm insulator supports. 3) The size of copper flat 1" x 1/4" shall be run inside bottom width of the panel for earth bus bar. 4) Necessary heat shrinkable sleeve should be provided to the above copper bus bar except earth flat. 5) 2 Nos. of danger boards to be fixed to the board.
2
-
359593.78
SITC of (30 plus 30) KVA parallel UPS;Design, fabrication, supply and errection of L.T indoor type cubical Lightning panel board made with 14 SWG CRCA sheet. The size of panel should be1600(w)mm x 2000(H)mmx 600(D)mm should be mounted on suitable base MS channel and fixing firmly as directed execution. The following switch gears, bus bars etc. should be supply and fixing in the panel firmly, and the panel with necessary individual doors, separate chambers for bus bars, out going cables etc. All the doors shall be provided with rubber beading and door knobs. The Top of the box should have provision for Incoming and Outgoing cables / Wire, The entire panel should be powder coated with siemens grey color through 7 tank process. Incoming:- 1). 1No. of 630A 3 Pole MCCB, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 50KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider-NS NSX/Legrand -DPX3/ Siemens-3VL / Hager- h3/C&S -Winbreak2Makes: GE / ABB / Havells / HPL / Standard / Indo Asian. Outgoing:- 1) 3 Nos. of Supply of 250A 3 Pole MCCB, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 36/35KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider- NS NSX/Legrand -DPX3/ Siemens-3VL / Hager-h3/C&S -Winbreak2 2) 1 Nos. of Supply of 125A 3 Pole MCCB, Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 36/35KA with thermal magnetic release Panel Mounted. Makes: L&T- D shine / Schneider- NS NSX/Legrand -DPX3/ Siemens-3VL / Hager-h3/C&S -Winbreak2. Metering:- 1) Supply and Fixing of energy analyser (multy function energy meter) with LCD/LED display capable of minimum 20 numbers electrical parameters display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc.c, omplete in all respect - 1No.2) Supply and Fixing of 240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required - 1Set Copper Bus bar arrangement:- 1) The size of copper flat 2" x 3/8" shall be run from 630A MCCB unit to vertical bus bar chamberwith 400x12x50mm insulators supports and shall be run vertically and horrizontally in Bus bar chamber fix the busbar with necessary insulators supports. 2) The size of copper flat 32 x 6 mm shall be provided to 250Amps MCCB connect to main bus bar and provide extension bits at out going side for cable connection with necessary bolts and nuts and using necessary 40x8mm insulator supports. 3) The size of copper flat 1" x 1/4" shall be run inside bottom width of the panel for earth bus bar. 4) Necessary heat shrinkable sleeve should be provided to the above copper bus bar except earth flat. 5) 2 Nos. of danger boards to be fixed to the board.
1
-
245531.59
SITC of (30 plus 30) KVA parallel UPS;Supply of 4 core 6 Sqmm PVC insulated and sheathed FRLS copper round cable for voltage up to 1100V as per IS 694/1990. Makes: Finolex / RR kabel / Havells /KEI/Polycab/ Gloster/Goldmedal/GM
500
-
158710
SITC of (30 plus 30) KVA parallel UPS;Supply of 140/0.3mm (10.0 Sqmm) FRLS-H / HFFR PVC insulated 1100V grade as per IS : 694 / 1990 specification for Copper cable. Makes: Finolex / RR kabel / Havells /KEI/Polycab/Gloster/Goldmedal/GM
100
-
9976