Military Engineer Services Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jul 2024
Closing Date22 Jul 2024
Tender Amount₹ 46,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filtration of transformer oil of transformers / FRMUs installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the Engineer-in-Charge.

4600

-

-

... More
Supply and topping up of transformer oil with di-electric strength not less than 60 KV into the conservator tank / body tank of the transformer / OCB / FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. Make: Apar (Power Oil) / Savita (Transol) / Asian

420

-

-

... More
M&L for rewinding of distribution (HT/LT) transformers of capacity 500 to 800 KVA type by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials / bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.

90

-

-

... More
All as per Sl item No. 6.00 but transformers of capacity 100 to 400 KVA

90

-

-

... More
M&L for re-insulating windings of HT / LT distribution transformers of capacity 100 to 800 KVA by strip opening of HT / LT coils (i.e. Primary / secondary coils) from core assembly safely, unwinding the HT / LT coils (i.e. Primary / secondary coils) complete, removing the old defective insulation paper and replacing with new DPC insulation to the copper conductor, re-varnishing of the windings with super varnish including heating, drying, backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as directed by Engr-in- charge.

40

-

-

... More
Disconnection of the distrubution transformer of capacity 100 to 800 KVA from HT and LT supply mains, removing of Bus duct and Bus bar, leakage arresting by draining out of oil after arrangement of necessary empty oil drums, buckets etc.,dismantling of top cover and acessories, dismantling of LT bushings by disconnecting leads / jumpers from inside, replacement of gaskets and oil seals and re fixing of the LT bushings, making internal and external connections, replacement of cover gasket and acessories, reassembling of acessories and cover, filling back of existing transformer oil complete and making cable connections and assesting for energising the transformer complete all as specified and as directed. Note: (i) The rate quoted shall include cost of materials like gaskets and oil seals and labour etc. (ii) Bushing and bushing rods shall be measured and paid separately.

8

-

-

... More
Disconnecting the HT / LT connections of transformer of capacity 100 to 800 KVA i.e (Bus duct / Cable bunch) keeping all the cables out from the HT/LT sides, physically checking the transformer for healthiness, performing the transformer tests like HV/LV Meggar test, Ratio Test, Magnetic Balance test and short circuit tests for checking condition of transformer complete all as specified and as directed. Note:- (i) All testing shall be done in presence of Engr-in-Charge or his accredited rep and test reports shall be signed by contractor and Engr-in-Charge and kept on record. (ii) If the transsformer found satisfactory then HT/LT connections shall be done by the contractor and has to charge the transformer. (iii) If the transformer fails in these tests then the contractor has to shift the transsformer for winding /overhauling which will be measured and paid separately. (iv) Cost of winding / overhauling if required shall be measured and paid separately.

6

-

-

... More
Shifting the Transformer of capacity 100 to 800 KVA from existing site to another site within 3 Km distance range by Dismantling of HT and LT cable connections, jumpers and busbars including LT busbar cable boxes and closing the transformers for loading into transporting vehicle with the help of crane, transportation to another site, unloading, cable connections both HT and LT, testing and commissioning complete all as specified and as directed.

3

-

-

... More
M&L for replacement of silica gel breather assembly complete suitable for 200 to 800 KVA transformer as per existing with breather unit and silica gel including connecting with proper necessary gaskets if necessary & removing the unserviceable breather assembly complete all as specified and as directed.

6

-

-

... More
S&F in repair conservator tank assembly suitable for transformer of capacity 200 to 800 KVA as per existing and including connecting properly with gaskets if necessary & removing the unserviceable conservator tank complete all as specified and as directed.

3

-

-

... More
S&F in repair gun metal drain valves suitable for transformer of capacity 200 to 800 KVA including dismantling old one complete all as specified and as directed. Make :- Upadhyay / Leader / Zoloto

6

-

-

... More
S&F in repairs off load tap changer assembly suitable for transformer of capacity 400 to 800 KVA as per existing with 7 tapping position including opening top cover, conservator etc complete all as specified and as directed.

1

-

-

... More
S&F in repair WTI (Winding Temperature Indicator) suitable for distribution transformer of capacity 400 to 800 KVA as per existing complete all as specified and as directed.

2

-

-

... More
S&F in repair LT bushings made out of porcelain alongwith bushing rod, as per existing and suitable for distribution transformer of capacity 500 to 800 KVA complete all as specified and as directed. Make:- Pactil / BHEL / Jaipuria Brothers

8

-

-

... More
S&F in repair HT bushings made out of porcelain alongwith bushing rod, as per existing and suitable for distribution transformer of capacity 500 to 800 KVAcomplete all as specified and as directed. Make:- Pactil / BHEL / Jaipuria Brothers

6

-

-

... More
S&F in repair Oil gauge glass with gaskets as per existing suitable for distribution transformers of capacity 500 to 800 KVA complete all as specified and as directed.

2

-

-

... More
M&L for preparation of old exposed painted surfaces of indoor / outdoor type transformer of capacity 500 to 800 KVA and painting the same with two coats of synthetic enamel paint including writing details of transformer on transformer plinth / base with white synthetic enamel paint on black synthetic enamel paint back ground complete & including one coat of white wash on exposed surface of transfomer plinth / base complete all as specified and as directed. Note :- Colour of paint shall be as decided by Engr-in-Charge. Make:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)

2

-

-

... More
S&F in repair OTI (Oil Temperature indicator) as per existing suitable for distribution transformers of capacity 500 to 800 KVA complete all as specified and as directed.

2

-

-

... More
S&F in repair drain plug & valve of conservator tank of suitable sizes as per existing suitable for distribution transformers of capacity 100 to 800 KVA complete all as specified and as directed.

6

-

-

... More
Clearing away all bushes, small plants, grass, vegetation, saplings, shrubs, brushwood, undergrowth, roots upto root level including surface dressing n.exc 15 cm deep around and surroundings areas of E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards, pump house & Misc E/M installations etc) and removing rubbish / debris upto a distance of not less than 50 metres outside the periphery of the area under clearance complete all as directed.

400

-

-

... More
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.

78

-

-

... More
Supply and laying hardcore of aggregate using 20mm graded crushed stone aggregate, deposited, spread and leveled in layers watered and rolled / rammed to a true surface in sub-station yards complete all as specified and directed. Note:- Thickness of aggregate shall be measured after compaction.

36

-

-

... More
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.

110

-

-

... More
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.

27

-

-

... More
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.

75

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, of size 300mmx 180mm x 40mm, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.

944

-

-

... More
S&F in repairs 100 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd

12

-

-

... More
M&L cable jointing kit for 11 KV (Earthed) grade 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm for outoor termination, heat shrink type joint complete with jointing material and accessories including taking down existing joints complete all as specified and directed. Make:- 3M / Denson / Raychem

3

-

-

... More
All as per Sl. Item No. 31.00 but suitable for cable of size 240 to 300 Sqmm

3

-

-

... More
M&L cable jointing kit for 11 KV (Earthed) grade 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm for straight through, heat shrink type joint with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem

8

-

-

... More
All as per Sl. Item No. 33.00 but suitable for cable of size 240 to 300 Sqmm

6

-

-

... More
Supply & laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, Earthed, grade cross sectional area 185 Sqmm, 3 core, laid in trenches / duct / on pole including taking down existing cable complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex

120

-

-

... More
All as per Sl. Item No. 35.00 above but for cable of size 240 sqmm x 3 Core

105

-

-

... More
M&L for detecting HT 11KV UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes complete all as directed. Note:- The rate quoted deemed to be inclusive of arrangement of necessary fault locator equipment, transportation of equipment& charges for service engineer.

6

-

-

... More
M&L for repair and servicing of HT (11) KV four pole structure by replacing Aluminium PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation sleeve RYB of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc and pin insulators and applying silicon compound for prevention of arcing due to dust / salt deposits over surfaces including preparation of surfaces, applying zinc chromate primer on rusted surfaces and applying one coat of aluminum paint to the entire structure complete all as specified and as directed. Note : Rate quoted shall be inclusive of two coats of white wash on exposed concrete surfaces of structure. Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)

1

-

-

... More
All as per Sl. Item No. 38.00 above but for two pole structure

4

-

-

... More
Servicing, Inspecting, checking, cleaning by using of blower, lubrication, greasing and carrying out preventive maintanance of RMU of capacity 11 KV, 250 / 350 MVA including calibrating the relay by conducting secondary injection tests and RMU in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. Notes: Unit rate quoted shall be deemed to include cost for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of RMU panels with approved colour including lettering details all as per exisitng.

10

-

-

... More
Supply & fixing in repair Self powered relay with O/C, S/C, E/F protection, having front USB port for laptop interface, LCD display,10 event records, 5 fault records, min 2 setting group and keypad for setting parameters for the relay complete suitable for RMU of capacity 11 KV, 250 / 350 MVA all as specified and as directed. Make:- Schneider / Siemens / L&T / ABB

2

-

-

... More
S&F in repair current transformer, Ratio - 100-50/5, accuracy class 1.0, burden - 2.5VA suitable for RMU of capacity 630 Amp complete all as specified and directed.

3

-

-

... More
S&F in repair cable termination bushing suitable for upto 1 run 3 core x 185 Sq mm, XLPE cable suitable for RMU of capacity 630 Amp complete all as specified and directed.

2

-

-

... More
S&F in repair cable termination cover boots, push on type suitable for RMU of capacity 630 Amp complete all as specified and directed.

3

-

-

... More
S&F in repair phase indicator lamps (Red, Yellow and blue) suitable for RMU of capacity 630 Amp complete all as specified and directed.

5

-

-

... More
S&F in repair 11KV, 230V, AC, 1KVA control transformer suitable for RMU of capacity 11 KV, 250 / 350 MVA complete all as specified and directed.

2

-

-

... More
S&F in repair Battery with & including battery charger, 12Ah, (I/P-230V AC, O/P - 24V DC suitable for RMU of capacity 11 KV, 250 / 350 MVA complete all as specified and directed. Make : Exide / Amron / Luminous / Amco / Nitco

2

-

-

... More
S&F in repair Spring charging motor suitable for RMU of capacity 11 KV, 250 / 350 MVA complete all as specified and directed.

3

-

-

... More
S&F danger notice plate of size 25 x 20 cm & 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT including dismantling old one compete all as specified and as directed.

20

-

-

... More
M&L in repairs disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green, two-in-series assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed. Make:- BHEL / Jaipuria Brothers / Pactil / Southern Insulators

3

-

-

... More
M&L pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed. Make:- BHEL / Jaipuria Brothers / Pactil / Southern Insulators

3

-

-

... More
M&L switches air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 volts all as per clause no 19.69 of SSR part-I (2009) including taking down old one complete all as specified and directed. Make:- Pactil / BHEL / Jaipuria Brothers

1

-

-

... More
S&F in repair drop out lift OFF HT 11 KV, 200 Amp fuse link consisting of channel iron base having 2 Nos 11 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze conforming to IS 9385 complete all as specified and directed. Make:- Pactil / BHEL / Jaipuria Brothers

1

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:2:4 type B1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.

12

-

-

... More
Disconnect and taking out IDMT / Numeric / Microprocessor based relay of any type & make from 11 KV HT panel at P-5 Sub Station NAD & TRS-II, cleaning the contacts, calibrating the relay by conducting secondary injection tests, checking of current transformer, rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relay and tripping coils, adjustment / setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping, tune / synchronise upstream breaker relay settings, re-installation of relay, testing & commissioning etc complete all as specified and as directed. Note:- (i) Arrangement of necessary testing / calibration kits, testing equipments, tools etc. shall be done by contractor and cost of the same shalll deemed to be included in the unit rate quoted. (ii) Testing & tuning shall be carried out in the presence of representative of the accepting officer to the entire satisfaction of the rep of GE.

13

-

-

... More
Taking down HT switch gear (Vacuum circuit breaker ) at P-5 Sub Station, TRS-I, TRS-II & FRCS Sub Station at NAD of capacity 11 KV, 250/350 MVA comprising of repairs, complete overhauling / servicing, carrying out preventive maintenance alongwith testing of breakers by current injection test and refixing the same after repair / overhauling complete all as specified and as directed. Note:- (i) The servicing includes for busbar duct chamber, cable alleys and connecting accessories (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning. (iii) Major spares like Breaker bushings, vacuum interrupter assly, busbar spout, busbar spout connections, circuit spout, circuit spout connections, buffer fixed contacts, moving contacts, tank assembly, barriers, solenoid spares, dependent, spring mechanism / motor mechanism, trip unit etc will be measured and paid separately under relevant items. However the rate quoted shall be deemed to include for any other minor spares requiring replacement. (iv) The servicing shall be carried out by auhtorised service engineer of OEM and approval of the same shall be taken from Engr-in-Charge.

13

-

-

... More
Supply only following spares suitable for 250 to 450 MVA HT switch gear VCBs and 11 KV HT panel repair work:-

-

-

-

... More
CTs epoxy cast wound, primary CTs with minimum primary current 50 to 100 A, double ratio, double core (Protection core-5P10/10P10 & Metering core- Class 1.0), 25 KA for 1 sec of 15 VA minimum Burden. (existing size)

3

-

-

... More
1.5 sqmm flexible PVC insulated multistranded copper conductor cable, unsheathed, 1100 V grade for control wiring. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL

90

-

-

... More
2.5 sqmm flexible PVC insulated multistranded copper conductor cable, unsheathed, 1100 V grade for control wiring. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL

90

-

-

... More
LED Indication Lamps

12

-

-

... More
Shunt trip coil 110 V DC/220 V DC

3

-

-

... More
Shunt trip coil 110 V DC/220 V DC Assembly

3

-

-

... More
Breaker control switch

3

-

-

... More
Busbar Spout

6

-

-

... More
Circuit spout

6

-

-

... More
Control circuit fuses 2 to 63 A

6

-

-

... More
HRC fuse (PT HT side)

6

-

-

... More
PT plug contact

3

-

-

... More
S&F multifunction meter, digital type (displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc.) Class 1/0.5 with RS485 port for communication in Modbus protocol, accuracy class-1, e- navigator, including taking down old one complete all as specified and as directed. Make:- Elmeasure / L&T / Schneider / HPL / SOCOMEC

4

-

-

... More
VCB buffers

10

-

-

... More
110 Volt DC closing coil assembly

3

-

-

... More
Push to trip knob red assembly

4

-

-

... More
Push to trip knob green assembly

4

-

-

... More
Ratchet wheel

2

-

-

... More
Nylon release lever

3

-

-

... More
VCB charging powl

3

-

-

... More
Shutters for racking shaft

2

-

-

... More
Bus bar support insulator for VCB panel

12

-

-

... More
Vacuum Interrupter Bottle VG2 Make : Schneider / Areva

3

-

-

... More
Rectifier

6

-

-

... More
Thermostat

12

-

-

... More
M&L for replacement of damaged space heater in HT VCB of capacity 11 KV with new one, suitable to operate on 110 Volts DC supply complete with necessary wiring and control cable with toggle switch complete all as specified and as directed.

12

-

-

... More
M&L for applying silicone High Voltage Insulator coating (Si-COAT 570 RTV) solution using electric airless sprayer to the inside surface of cable chamber alongwith busbar chamber of 11 KV Indoor VCB panel including all disconnection & re-connection of cables etc. complete all as specified and directed.

45

-

-

... More
Supply, Install, Testing and commissioning of Mi-Com Feeder Protection and Control Relay, Measurement for KW, KVA, PF, Hz, Kwh, 12 DI + 10 DO, One front RJ45 POrt, One Rear RS485 POrt for Modbus Protocal, Draw out Type with CT shorting feature, small LCD Display feature including taking down old relay of any descpriton complete all as specified and directed by Engineer-in-Charge. Make: ABB/Siemens/Schneider

2

-

-

... More
S&F in repair lightning arresters expulsion type complete with all fittings, station class, discharge capacity 10 kilo amp suitable for 11000 volts complete all as specified and directed. Make:- Oblum / Elpro / BHEL / Areva T&D / Jaipuria Brothers

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.