To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date27 Aug 2024
Closing Date18 Sep 2024
Tender Amount₹ 88,02,044
Costs
EMD
₹ 1,76,041Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Construction Of 01 Arts Craft Room 01 Library Room At Gss Mus,car Nicobar Under Samagra Shiksha.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_APWD_15339_1Tender No
e-tender-DB/CD/CN/2024-25/1402Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://apwd.and.nic.in/APWD/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift
135.9
-
-
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
11.5
-
-
Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
-
-
-
All kinds of soil
200
-
-
CEMENT CONCRETE (CAST IN SITU)
-
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
10.8
-
-
1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
11.1
-
-
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
16
-
-
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
16
-
-
REINFORCED CEMENT CONCRETE
-
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
34
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fllets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
-
-
-
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
13.8
-
-
Reinforced cement concrete work in beams, suspended foors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to foor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
40.75
-
-
Centering and shuttering including strutting, propping etc. and removal of form for
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete.
52.4
-
-
Walls any thickness) including attached pilasters, butteresses, plinth and string courses etc.
74
-
-
Suspended floors, roofs, landings, balconies and access platform
98.3
-
-
Shelves (Cast in situ)
7
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
280.4
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts
172.5
-
-
Stairs, (excluding landings) except spiral-staircases
19.1
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more.
4158.74
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more.
8213.08
-
-
WOOD AND P. V. C. WORK
-
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
-
-
-
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
9.45
-
-
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
-
-
-
300x16 mm
4
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
-
-
-
200x10 mm
8
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
-
-
-
125 mm
16
-
-
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
-
-
-
Twin rubber stopper
8
-
-
STEEL WORK
-
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
686.2
-
-
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
-
-
-
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6(1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
1300
-
-
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
-
-
-
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
77.7
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
-
-
-
Electric resistance or induction butt welded tubes
3431
-
-
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
60
-
-
Providing and fixing bolts including nuts and washers complete.
88.4
-
-
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
-
-
-
G.I. pipes
571.14
-
-
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
-
-
-
4.0 mm thick glass panes (weights not less than 10 kg/ sqm)
67.27
-
-
FLOORING
-
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
-
-
-
40 mm thick with 20 mm nominal size stone aggregate
85.2
-
-
ROOFING
-
-
-
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
-
-
-
6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862:2000
88.4
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
136.5
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws cmplete:
-
-
-
Ridges plain (500 - 600mm)
40.7
-
-
Barge board (Upto 300 mm)
47.4
-
-
FINISHING
-
-
-
12 mm cement plaster of mix :
-
-
-
1:4 (1 cement: 4 fine sand)
659.8
-
-
6 mm cement plaster of mix :
-
-
-
1:3 (1 cement : 3 fine sand)
139.24
-
-
White washing with lime to give an even shade :
-
-
-
New work (three or more coats)
137.6
-
-
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete:
-
-
-
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 pram/litre
309.8
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade .
-
-
-
New work (Two or more coat applied @ 1.67 ILO 0 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sarM
350.03
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
-
-
-
Two or more coats on new work
31.2
-
-
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
-
-
-
Two or more coats on new work
69.5
-
-
ALUMINIUM WORK
-
-
-
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in- charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
456.14
-
-
Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge.
146
-
-
Non Schedule
-
-
-
Providing and laying hollow cement concrete blocks walling up to floor five level 200mm thick using hollow block of size 400mm x 200mm x 200mm of mix 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 12.50mm nominal size) having a crushing strength of 3.5 N/mm2 at 28 days as per I.S. 2185 (Part I) 1979 laid in cement mortar 1:6 (1 cement: 6 coarse sand) complete.
42.2
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:
(a) Water thinnable cement primer.
309.8
-
-
Applylying priming coat:
(a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
32
-
-
Making plinth protection 50mm thick if cement comncrete 1:3:6 (1cement:3 Coarse sand:6 graded stone aggregate 20mm nominal size) over 75mm bed by stone aggregate 40 mm nominal size well rammed and consolidated and grounted with fine sand including finishing the top smooth.
22.6
-
-
Providing cement concrete surface drain including earth excavation 10 cm thick base concrete and 15 cm thick side walling with 1:3:6 cement concrete ( 1: cement; 3 sand; 6: graded stone stone aggregate 40mm nominal size) cement concrete fininshing with 1:4 cement mortar (1 coment: 4 sand) cement plaster including floating coat of neat cement inside the drain surface including disposal of surplus earth work complete. (a) 15X15 cm
50.8
-
-
Extra for providing and fixing wind ties of 40x6 mm flat aluminium section etc complete as per the direction
63.4
-
-