Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date24 Feb 2024
Closing Date20 Mar 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_639451_1Bid Award Id
ViewTender No
8109/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for providing 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed.
79.8
-
-
M & L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundation, fillings and mass concrete complete all as specified and as directed.
12.5
-
-
M & L for providing 75mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection complete all as specified and as directed.
27
-
-
S & F MS sections as in ISMC, ISMB, angle, main and cross beams, hip and jack rafters; purlins, rolled section where connected to common rafters and running rails and guides for truss/ column/ staircase/ ladder/ high strength friction grip bolt grade 10.9s for columns, beam etc., base plates/ gusset plates, wind tie, doors etc., including cutting, welding etc., fixed with angle cleats or other connecting plates complete all as specified and as directed.
5490
-
-
S & F mild steel framed work such as grills, gratings etc, with end of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, waterways, railing and similar work conforming to Fe-410-O or Fe-310-O complete all as specified and as directed.
1000
-
-
S & F pre-painted galvalume aluminium zinc coating GI based corrugated mild steel sheet 0.50mm thick of any colour with two corrugations side lap having tensile strength of minimum 550 MPa as in roof covering/ cladding to wall, fixed with L-type or J-type or cranked hook bolts in lieu of screws complete all as specified and as directed.
112
-
-
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
40
-
-
S & F for 1.00mm thick galvanised steel sheet as in valley gutters fixed with rivets or other suitable arrangements over MS brackets, trapezoidal shape of required profile with desired slope etc., complete all as specified and as directed.
29
-
-
S & F 160mm dia PVC (SWR) pipes double socketed in any length with rubber ring joints fixed with wall including all connecting accessories complete all as specified and as directed
18
-
-
S & F for PVC (SWR) bends any radius 160mm bore complete all as specified and as directed.
20
-
-
M & L for Precast cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and set in CM (1:4) complete all as specified and directed.
6
-
-
M & L for rendering 15mm thick plaster in CM(1:4) on walls, finish the surfaces even and smooth (without using extra lime or cement) complete all as specified and as directed.
30
-
-
M & L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of approved primer on plastered surfaces complete all as specified and as directed.
30
-
-
M & L for rendering 20mm thick plaster on walls in CM(1:6), in two coats (15mm thick backing coat + 5mm thick finishing coat) on fair faces of brick work/ PCC cement block, finish the surfaces even and smooth complete all as specified and as directed.
30
-
-
M & L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10Sqm over new surfaces and applying plaster of paris putty of 1mm thick over plastered surfaces to prepare the surface even and smooth complete all as specified and as directed.
30
-
-
M & L for preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
190
-
-
Removing excavated material (surplus soil) to a distance exc 250m and n.exc 500m depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed.
26
-
-
M & L for providing 125mm thick PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed.
3
-
-
M & L for 1.25mm thick galvanised steel sheet as in valley gutters fixed with rivets or other suitable arrangements over MS brackets trapezoidal shape of required profile with desired slope etc ., complete all as specified and as directed.
25
-
-
S & F 160mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed.
24
-
-
S & F false ceiling with powder coated exposed GI grid suspension system a grid of 600mm x 600mm, grid of modular size 600mm x 600mm shall be supported by 4mm dia GI wire from purlins/ soffit with and including 8mm thick high pressure steam cured non asbestos fibre cement designer ceiling board (of density 1200 Kg/Cum) of size 595mm x 595mm complete all as specified and as directed.
30
-
-
E/M PORTION
M & L for point wiring complete with 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor 1100V grade drawn through in and including 20mm dia PVC conduit on wall/ ceiling and terminated to MS box of 1.6mm thick and 3mm thick hylam sheet for mounting switches, sockets etc, including 1.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly for one light/ fan point controlled by one way 5 Amps switch complete all as specified and as directed.
10
-
-
M & L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduit of suitable size and connecting terminal ends to plug sockets and DB's including provision of 1 run of 6 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly complete all as specified and as directed.
Note : (i) 3 Runs of 6 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
20
-
-
S & F switch piano type 1 way 6 Amps complete all as specified and as directed.
10
-
-
S & F sheet metal enclosure DB 230 Volts single phase 50 Hz, 200 Amps bus bar 4 way double door complete all as specified and as directed.
1
-
-
S & F MCB SP 230 Volts, 50 Hz current rating upto 6 to 32 Amps, C Series with breaking capacity of 10KA complete all as specified and as directed.
8
-
-
S & F two pole Isolator 230 volts, 50 Hz current rating upto 40 Amps complete all as specified and as directed.
1
-
-
S & F LED light fitting 1 x 18W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
10
-
-
S & F of ceiling rose two/ three terminal surface backelite type complete all as specified and as directed.
10
-
-
M & L for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth of not less than 2.25mtr below ground level than 1.5mtr below ground level connected to GI earth wire 4mm dia by means of bolts washers etc., made out of GI earth wire protected by galvanized iron pipe medium grade 15mm bore up to main distribution board/main switch including necessary excavation and earth work PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) RCC cover 1:2:4 type B-1 including necessary reinforcement etc complete all as shown in electric plate No.3 of MES schedule Part-I., taking down old earthing items in any type of soil complete all as specified and as directed.
Note:- (i) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost (ii) Earth work is deemed to be included in the quoted rate.
2
-
-
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures stay rods, laying of underground cable etc all as specified and as directed.
30
-
-
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each n.exc 25cm thick complete all as specified and as directed.
27
-
-
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
3
-
-
Supply and lay GI tubing 50 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and as directed.
6
-
-
Supply,testing,laying and commissioning of XLPE insulated, armoured heavy duty underground electric cable with stranded aluminium conductor, 1100 volts grade of cross sectional area 6 Sqmm 2 core laid in trenches / fixing on walls / poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required complete all as specified and directed.
130
-
-
M & L HDPE Double Wall Corrugated (DWC)pipes conforming to IS-14930 Part with IP protection IP-67 having inner dia 50mm including necessary pipe fittings such as couplers,end caps,bends,clamps etc laid in trenches/on wall for cable protection complete for cable protection complete all as specified and directed by Engr-in-charge. Make : Gemini/ Telerex/ Prince
120
-
-
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
6
-
-
Supply & install hi-wall split AC units indoor / outdoor complete with cordless remote control unit and with in built cooling arrangements and digital invertor twin rotary of capacity 1.5 TR 5 star rating complete all as specifed and as directed.
4
-
-
Supply, install, testing and commissioning of Voltage Stabilizer for automatic correction and operation single phase neutral air cooled split type and designed for input various between 170 to 250 V with output stabilizer at 230V with necessary +/- 2.5% and of capacity 4 KVA complete all as specified and as directed.
4
-
-
S & F DB with metal clad plug and socket control by MCB 20 Amps capacity operating on 230 AC 50 Hz electric supply complete all as specified and as directed.
4
-
-
M & L for point wiring complete with 4 Sqmm PVC insulated unsheathed single core multi stranded copper conductor 1100 V grade drawn through in and including 25mm dia PVC conduit on wall/ ceiling and terminated to MS box of 1.6mm thick and 3mm thick laminated hylam sheet top cover for fixing switches/ sockets etc including 4 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly for power point 3/5 pin AC point complete all as specified and as directed.
4
-
-
M & L for sub main wiring complete with 2 runs of 10 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduit of suitable size and connecting terminal ends to plug sockets and DB's including provision of 1 run of 10 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly complete all as specified and as directed.
Note : (i) 3 Runs of 10 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
30
-
-
S & F sheet metal enclosure SPN DB 8 way double door with 100 Amps rated bus bar 240 volts 50 Hz complete all as specified and as directed.
1
-
-
S & F MCB SPN 240 Volts, 50 Hz current rating upto 40 to 63 Amps, C Series with breaking capacity of 10KA complete all as specified and as directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements