Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Jun 2024
Closing Date8 Jul 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_652987_2Bid Award Id
ViewTender No
8133/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply only the following Items of DG Sets of capacity 160 KVA to incorporate against each Item of Schedule 'A' here-in-above (a) Engine Oil Filter Assembly.
10
-
-
(b) Fuel Filter Assembly
10
-
-
(c) Air Filter Assembly
10
-
-
(d) Engine Oil (15W20)
540
-
-
(e) Coolant
35
-
-
M & L for removing defective AVR from Alternator and replacing with new AVR upto 250 KVA DG sets of make as per existing complete all as specified and directed by Engr-in-Charge.
1
-
-
M & L for replacing the old unserviceable battery lead with copper terminals approximately 2.5 mtr length including applying jelly over the battery pole and terminals complete all as specified and as directed by Engr-in-Charge.
2
-
-
M & L for replacing the old unserviceable battery terminals (Positive & Negative ) including brazing work and applying jelly over the battery pole and terminals complete all as specified and as directed by Engr-in-Charge.
2
-
-
Taking down the existing worn out Fanbelt (V Belt) for DG of 250KVA capacity installed at various installation and replaced with new fan belt complete all as specified and directed by Engr-in-Charge.
3
-
-
S & F Battery 12 V 180 AH for DG set complete all as specified and directed by Engr-in-Charge.
Make : AMCO /EXIDE/TATA
1
-
-
Taking down the existing Volt meter /Ammeter /Frequency Meter of any capacity DG set from the panel board and replace with new digital Voltmeter/ Ammeter /Frequency Meter including necessary wiring and wiring material all as specified and directed by the Engineer-in-charge. Make: AE/MECO
1
-
-
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
124
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soil all as specified and as directed.
112
-
-
Removing excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed.
12
-
-
M & L XLPE, insulated, armoured, heavy duty, electric cable of cross sectional area of size 3.5 Core x 150 Sqmm with stranded aluminium conductors, 1100 volts grade, laid in tranches / fixing on wall /poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, including taking down existing unserviceable cable with GI protections pipes, complete all as specified and as directed by Engr-in-Charge. Make : Havells / Polycab / Finolex / Gloster
340
-
-
Description all as per Item No 14 above but of cross sectional area of size 3.5 Core x 70 Sq mm complete all as specified and as directed by Engr-in-Charge.
Make : Havells / Polycab / Finolex / Gloster
170
-
-
Description all as per Item No 14 above but of cross sectional area of size 2 Core x 16 Sq mm complete all as specified and as directed by Engr-in-Charge.
Make : Havells / Polycab / Finolex / Gloster
50
-
-
Description all as per Item No 14 above but of cross sectional area of size 2 Core x 6 Sq mm complete all as specified and as directed by Engr-in-Charge.
Make : Havells / Polycab / Finolex / Gloster
50
-
-
S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP protection of IP-67 having outer dia 120 mm and inner dia of 103 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
500
-
-
S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed.
215
-
-
S & F GI pipe 50mm bore light grade with all fittings laid in trenches /on wall / on poles etc/ for protection complete all as specified and as directed.
30
-
-
Supply and installation LED 45 W Street Light, IP-66 (Waterproof) Outdoor Light, Cool White with BIS approved driver, heat management with aluminum heat sink, with protections available -short circuit, open circuit, under voltage, over voltage, insolution, 6kv - internal surge protection complete all as specified and as directed. Make : - Philips / Wipro/ Havells/ CG/ Jaquar
10
-
-
Repair of bollard light fittings including replacement minor spare parts complete all as specified and as directed by Engr-in-Charge.
12
-
-
S & F driver for LED flood light fittings of capacity upto 150 watts complete all as specified and as directed.
4
-
-
S & F driver for LED street light fittings of capacity upto 70 watts complete all as specified and as directed.
10
-
-
Supply and installation LED 150 W Flood Light, IP-66 outdoor light, cool white with BIS approved driver, heat management with aluminum heat sink, with protections available -short circuit, open circuit, under voltage, over voltage, isolution, 6kv - internal surge protection complete all as specified and as directed. Make : - Philips / Wipro//Havells/ CG/ Jaquar
3
-
-
S & F post top lantern LED type 35 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Make : - Philips / Wipro//Havells/ CG/ Jaquar
2
-
-
S & F bollard type LED type, 10 watt, 300 lumens, warm white, 230 volts AC outdoor type with decorative bollard light IP 65, IK10 impact protection with impact and corrosion resistant with driver and lamp complete all as specified and as directed. Make : - Philips / Wipro//Havells/ CG/ Jaquar
8
-
-
S & F PVC junction box of size 140 x 140 x 95 mm, light weight pole mounting hinged type including necessary clamp for MCB mounting and mounting of box on pole /pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as specified and as directed. Make : Sintex / Hensel
8
-
-
S & F PVC junction box of size 270 x 225 x 135 mm, light weight pole mounting hinged type including necessary clamp for MCB mounting and mounting of box on pole /pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as specified and as directed Make : Sintex / Hensel
2
-
-
M & L for preparation of old painted surfaces of steel tubular / RCC pole upto 11 mtr and cleaning the surface etc. and applying two coats of synthetic enamel paint based paint white colour and in bottom black colour including applying two coats of synthetic enamel paint silver colour all details complete all as specified and as directed by Engr-in-Charge.
60
-
-
M & L for preparation of old painted surfaces of LT feeder piller box/HT & LT panels by scrapping with wire brush and cleaning etc. and applying two coats of synthetic enamel paint with use of spray gun of approved grey colour and writing the all details as per direction with white colour in back ground complete all as directed by Engr-in-Charge.
14
-
-
Dismantling unserviceable burnt out Timer by disconnecting the cable and S & F new three phase timer 32 Amps, street light control panel with digital type, control relay, contactor in the existing panel boards with new bolts, nuts, lugs & glands etc of the following capacities complete all as specified and directed.
2
-
-
S & F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) complete all as specifed & directed by Engr-in-Charge.
2
-
-
Supply and laying PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping of poles complete all as specified and as directed.
1
-
-
Supply and laying PCC(1:2:4) type B-2 (using 40mm graded stone aggregate) for foundation of poles complete all as specified and as directed.
1.08
-
-
Dismantling unserviceable burnt out MCCB by disconnecting the cable and S & F new MCCB's in the existing panel boards with new bolts, nuts, lugs & glands etc of capacity MCCB 63 to 100 A adjustable type, 4 pole 25 KA, 415 Volts complete all as specited and directed.
Make: L&T, Legrand, Havells
4
-
-
Description all as per Item No 33.00 above but of capacity MCCB 125 /160A adjustable type, 4 pole 25 KA, 415 Volts complete all as specified and as directed.
4
-
-
Description all as per Item No 33.00 above but of capacity MCCB 200 A adjustable type , 4 Pole 36 KA, 415 Volts complete all as specified and as directed.
1
-
-
Taking down old unserviceable point wiring, (light, fan, socket or power) complete including fittings & fixtures such as switch, ceiling rose, pendants, fan regulator, socket, etc., and making good the disturbed surface of wall, floors, ceiling etc to match with the existing including touch up of paint/white wash all as specified and directed by Engr-in-Charge.
142
-
-
M & L for point wiring with 1.5 Sq mm copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing/conduit surface type and accessories of suitable size ISI marked and PVC terminal boxes of 1.6 mm thick of suitable size including fixing/grouting sunken box both normal & modular type/ surface/ comcealed on wall & roof as per site requirement including provision of modular cover plates & normal hylum sheet, the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for One light/fan point controlled by one, one way switch 5 Amps complete all as specified and as directed.
80
-
-
Description all as per Item No 35.00 above but One call bell point controlled by one, one way switch 5 Amps complete all as specified and as directed.
4
-
-
Description all as per Item No 35.00 above but One 3/5 pin 5 Amp socket independent controlled by one, one way switch 5 Amps complete all as specified and as directed.
32
-
-
Description all as per Item No 35.00 above but One 3/5 pin 5 amp socket same board controlled by one, one way switch 5 Amps complete all as specified and as directed.
10
-
-
M & L for point wiring with 2.5 Sq mm copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing/conduit surface type and accessories of suitable size ISI marked and PVC terminal boxes of 1.6 mm thick of suitable size including fixing/grouting sunken/ surface/ comcealed on wall & roof as per site requirement including provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 2.5 Sq mm multistranded copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for One 3/5 pin 15 amp socket independent controlled by one, one way switch 15 Amps complete all as specified and as directed.
16
-
-
S & F switch piano single pole flush type 5 Amps, 230 volts complete all as specified and directed.
115
-
-
S & F switch socket combination flush type multipurpose 2/3 pin 5 Amps 2 in 1, 230 Volts complete all as specified and as directed.
47
-
-
S & F switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 Amps flush type universal complete all as specified and as directed.
18
-
-
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc., as required all as specified and as directed.
25
-
-
S & F Bell push, flush type, 5 Amps complete all as specified and as directed.
4
-
-
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
97
-
-
S & F in repairs Bell, Ding Dong AC 230 volts, single pole complete all as specified and as directed.
4
-
-
S & F Modular switch 1 way 6 A, 1 Module complete all as specified and as directed.
22
-
-
S & F Modular switch 1 way 16 A, 1 Module complete all as specified and as directed.
8
-
-
S & F Modular Socket 6A-2/3 pin combined 2 module complete all as specified and as directed.
10
-
-
S & F Modular Socket 6A/16-2/3 pin combined 2 module complete all as specified and as directed.
8
-
-
S & F Modular Fan step regulator, 120W-2 Module complete all as specified and as directed.
4
-
-
M & L for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2 x 4.0 Sqmm drawn into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete all as specified and as directed.
Note : (i) 3 Runs of 4 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
145
-
-
M & L for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2 x 6.0 Sqmm drawn into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete all as specified and as directed.
Note : (i) 3 Runs of 6 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
45
-
-
S & F in replacement sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed.
5
-
-
S & F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed.
5
-
-
S & F MCB SP 6 to 32 Amps 240V 10 KA. "C" Series complete all as specified and as directed.
40
-
-
S & F MCB SPN upto 32 Amps 240V 10 KA. "C" Series complete all as specified and as directed.
18
-
-
S & F MCB TP upto 32 Amps 415V 10 KA. "C" Series complete all as specified and as directed.
5
-
-
S & F MCB TPN upto 63 Amps 415V 16 KA. "C" Series complete all as specified and as directed.
Note for Item No 53.00 to 56.00 :- MCBs / MCCBs will have to suite upon with the base of the existing Panel / DB as per site requirement
4
-
-
S & F ultra bright LED tube rod 18/20 with out put of 1800 lumens (single side connection) with very high efficacy suitable for installation in existing tubelight G13 lamp holders to give glare free light with necessary wiring and removal old existing unsv tube from fitting complete all as specified and as directed. Make :- Philips/ Wipro/ Havells/ Jaquar
40
-
-
S & F LED bulb 9/10 Watt complete all as specified and as directed.
Make : - Philips/ Havells/ CG/ Wipro
25
-
-
S & F wall mounted LED 18/20 watts with out put of 1800 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium body heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 18/20 watts including removal old existing unsv tube light fitting complete all as specified and as directed.
Make : Philips/ Havells/ CG/ Wipro/ Jaquar
80
-
-
S & F surface mounting 10 Watt LED luminaries with epoxy white powder coated CRCA sheet steel housing with reeded translucent acrylic diffuser and 1 x 10 Watt LED fitting including taking down old unserviceable fittings any type complete all as specified and as directed . Make : Philips/ Havells/ CG/ Wipro/ Jaquar
22
-
-
Taking out the existing any type fittings on ceilings and S & F 36 Watt LED luminaire suitable for 600 x 600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 3600 total lumen. The 36 W system shall be operating at 220-240 volt AC supply having internal driver IP 20, surge protection 2KV, ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz. The system efficacy must be between 80-100 lumen /watt , with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than 0.95 , THD 10% . Indivisual LED's should not be visible for glare free output ,colour temperature 6500k all as specified and as directed.
Make : Philips/ Havells/ CG/ Wipro/ Jaquar
10
-
-
Taking down the ceiling / Exhaust fans of any model, size & sweep carefully from its original position and dismantling motor and over hauling complete by cleaning all dust / grease with kerosene or petrol, & replacement of unserviceable bearings, bushes, split pins and nut and bolts and applying new grease for bearings, reassembling the motor and fixing the blades, preparation old surfaces of fan of any sweep & model and painting the with synthetic enamelled paint by spraying including filling cavities and testing and refixing the same complete as directed by Engr in Charge.
Note for Item (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoted against this Item.
(ii). Any unforeseen minor repair and minor parts like Rubber bush, MS Clamps, split pins, base frames, nuts, bolts etc are also deemed to be included with unit rate.
48
-
-
Supply only following spares of ceiling / exhaust fan of any model, size & sweep to incorporate against each Item of Schedule 'A' here-in-above Item complete all as specifed & directed
(a) Supply only ball bearing suitable for ceiling fan upto 1400 mm sweep complete all as specified and as directed.
45
-
-
(b) Supply only ball bearing suitable for Exhaust fan upto 600 mm sweep complete all as specified and as directed.
9
-
-
(c) Supply only GM bush for C/fan and E/fan complete all as specified and as directed.
34
-
-
M & L for rewinding the motor of ceiling Fan upto 1400mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size complete including taking out burned unserviceable copper winding wire complete all as specified and as directed.
35
-
-
M&L for rewinding the motor of exhaust Fan upto 600mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size complete including taking out burned unserviceable copper winding wire complete all as specified and as directed.
10
-
-
S & F in repairs capacitor 2.5 MFD capacity including removal of unserviceable ones complete all as specified and directed.
80
-
-
S & F in repairs capacitor 4 MFD capacity including removal of unserviceable ones complete all as specified and directed.
8
-
-
Supply only the following Items of DG Sets of capacity from 62.5 KVA & 250 KVA to incorporate against each Item of Schedule 'A' here-in-above: (a) Spin-On Lub Oil Filter. Part No 06.436.01.0.00 complete all as specified and as directed.
14
-
-
(b) Spin-On Filter Assembly. Part No - F6.009.04.0.00 complete all as specified and as directed.
7
-
-
(c) Fuel Filter Pre. Part No 48.117.04.0.00 complete all as specified and as directed.
7
-
-
(d) Fuel Filter Micro. Part No 48.117.05.0.00 complete all as specified and as directed.
7
-
-
(e) Air Filter Safety. Part No - F6.404.28.0.00 complete all as specified and as directed.
4
-
-
(f) Air Filter Primary. Part No - F6.404.27.0.00 complete all as specified and as directed.
4
-
-
(g) Spin-On Lub Oil Filter. Part No 04.270.01.0.00 complete all as specified and as directed.
6
-
-
(h) Fuel Filter Pre. Part No 3H.132.01.0.00 complete all as specified and as directed.
3
-
-
(j) Fuel Filter Micro. Part No 3H.132.02.0.00 complete all as specified and as directed.
3
-
-
(k) Air Filter Safety. Part No - 6H.411.02.0.00 complete all as specified and as directed.
2
-
-
S & F for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SPN MCB including removal old unsv one complete all as specified and as directed.
2
-
-
M & L for taking out & servicing Split type air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5/ 2.0 TR of any make and any type by replacing unserviceable parts from the machine including charging of Refrigerant gas after vacuuming and leak testing. Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, checking of electrical circuit and replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning & refixing in same or new location complete all as specified and directed.
Note:- i) Compressor and major spare parts where ever is required shall be measured and paid separately under respective item. ii) During vacuming the machine existing Refrigerant shall be collected in cylinder and the same shall be reused while charging after carry out of repair and additional qty required for smooth functioning shall be measured and paid separately under respective item.
12
-
-
Supply only electric blower fan motor of split AC 230 volt 1340 RPM single shaft with ball bearing for any make split AC 2.0 Ton capacity complete all as specified and directed.
2
-
-
Supply only running capacitor upto 50 (+,- 6) MFD and complete all as specified and directed.
5
-
-
Supply only starting capacitor 100/120 MFD complete and complete all as specified and directed.
2
-
-
S & F for indoor unit Condenser coil of split type air conditioner 1.5 ton capacity wall mounted operation and performing on cooling system of make as per site requirement including removal of old existing unsv one complete all as specified and directed.
1
-
-
Taking down existing unserviceable outdoor Condenser coil unit and supply and fix new outdoor Condenser coil unit for 1.5 TR capacity Split AC working with compressor of make as per site requirement complete all as specified and directed.
1
-
-
S & F for flexible PVC/hose pipe 20 mm dia heavy duty from outdoor unit including removal of old existing unsv one complete all as specified and directed.
40
-
-
M & L for filling up & charging of R - 22, 32, 410a etc refrigerant or type of gas as per site requirement for window/spilt type air conditioner of any capacity refrigerator, deep freezer and water cooler of capacity 80/40 litres after leak testing of complete system and making good by bracing complete all as specified and directed.
6
-
-
S & F AC copper pipe 12.7 mm dia including removal of old existing unsv one complete all as specified and directed.
6
-
-
S & F AC copper pipe 6.35 mm dia including removal of old existing unsv one complete all as specified and directed.
5
-
-
S & F for PCB (Printed circuit board) of indoor unit suitable for existing upto 2.0 ton capacity split AC including removal of old existing unsv one complete all as specified and directed.
2
-
-
Removing the old unserviceable sealed compressor unit from split AC of any make, capacity 2.0 TR and supply and fixing new hermetically sealed compressor of same make as that of the existing for split AC of capacity 2.0 TR with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed.
1
-
-
S & F XLPE, insulated, armoured, heavy duty, electric cable size 16 Sqmm 2 core with stranded aluminium conductors, 1100 volts grade, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, including taking down existing unserviceable cable with GI protections pipes, complete all as specified and as directed.
130
-
-
S & F LED 100 W Flood Light, IP-66 Outdoor Light, Cool White with BIS approved driver, heat management with aluminum heat sink, with protections available -short circuit, open circuit, under voltage, over voltage, isolution, 6kv - internal surge protection complete all as specified and as directed. Make : - Philips / Wipro/ Luker/ Havells/ CG
2
-
-
M & L for preperation of old painted surfaces of two pole RCC structural and transformer and cleaning the surface etc. and applying two coats of synthetic enamel paint based paint white colour and in bottom black colour including applying two coats of synthetic enamel paint silver colour on bracket of street lights and on clamps, writing the all details as per direction complete all as specified and as directed.
4
-
-