Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date28 Mar 2024
Closing Date11 Apr 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_639167_2Bid Award Id
ViewTender No
8048/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in flooring and rounded or chamfered on edges complete all as specified and as directed.
2
-
-
Dismantling posts or struts (wood, steel or RCC) any section including taking out embedded portion and making good disturbed ground, posts embedded in natural ground all as specified and as directed.
16
-
-
Dismantling of barbed wire fencing coiled on drum for reuse complete all as specified and as directed.
7
-
-
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, pier hole etc., n.exc 10 Sqm on plan and getting out in any type of soil all as specified and as directed.
10
-
-
M & L for providing cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation, filling, plinth protection and mass concrete all as specified and as directed.
3
-
-
M & L for pre-cast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in posts, fencing posts, straining or terminal posts, struts etc., for fencing average sectional area exc 100 and n.exc 250 Sqcm with or without chamfered angles and flat, splayed, rounded or mitered tops all as specified and as directed. Note : Reinforcement shall be measured and paid separately.
0.8
-
-
M & L for mild steel TMT bars 10mm dia and over cut to length bent to shape required for fixing including cranking bending spirally for hooping ends and binding with and including mild steel wire (ammended) not less than 0.9mm dia all as specified and as directed.
430
-
-
Description all as per Item No 10 above but 6 to 8 mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc., complete all as specified and as directed.
100
-
-
S & F wind ties format including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessay drilling, bolting or riveting etc, and similar work confirming to Fe 290 Gde E-165 all as specified and as directed.
300
-
-
S & F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc., all as specified and as directed.
Note :Each line wire to be measured.
5
-
-
Fixing only 2 strand steel barbed wire 2.24 mm dia barbed wire with 2 mm barbs at 75 to 100 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized MS wire staples or steel pins etc., all as specified and as directed.
Note : Each line wire to be measured.
2
-
-
S & F framed works as in doors or gates or fencing post of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks or hinges or steel hanging door fittings and similar works confirming to Fe-290 Gde-E-165 all as specified and as directed.
800
-
-
M & L for preparation of new or previously untreated steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
60
-
-
M & L for painting on new steel surfaces n.exc, 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
12
-
-
Demolition of precast cement concrete block walling as in manhole, septic tank and drains etc built in cement mortor, including all quoins, arches pillars etc but excluding ashlar facings, dressed stone work etc and removing unserviceable debris off the premises all as specified and as directed.
4
-
-
Taking down of cement plaster of any description or thickness /chipping of cement concrete in any situation from brick or concrete surface including raking out of joints, hacking for key scrubbing down with water to receive new plaster complete all as specified and as directed.
160
-
-
M & L for precast cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and set in CM (1:4) complete all as specified and directed.
4
-
-
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished even and smooth (without using extra cement) on walls complete all as specified and as directed.
100
-
-
M & L for preparing new plastered surfaces of wall and applying two coats of cement based paint all as specified and as directed.
100
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any kind of soil depth all as specified and as directed.
6
-
-
Removing excavated material (soil) to a distance exc. 250m but n.exc 500m and depositing where directed at a level n exc 1.5m above the starting point all as specified and as directed.
4
-
-
M & L for rendering 15mm thick in CM (1:6) on brick work or concrete surfaces, finished even and smooth on walls complete all as specified and as directed.
80
-
-
M & L for cleaning the chocked soakage of manholes of any size and depth and removing scum /sludges to a distance exc 250m and n.exc 500m and cleaning with fresh water by taking out carefully cover slab placing in position including setting the cover slab in CM (1:6) complete all as specified and as directed
30
-
-
M & L for cleaning of blocked CI pipe line 100 mm bore, carefully in between manholes using spllited bamboo, cleaning rod, binding wire etc and flush with fresh water and disposed off the sludge complete all as specified and as directed.
60
-
-
M & L for cleaning of blocked CI pipe line 150mm bore, carefully in between manholes using splited bamboo cleaning rod, binding wire etc and flush with fresh water and disposed off the sludge complete all as specified and as directed.
60
-
-
M & L for removing RCC cover slab of septic tanks of various capacities and taking out scum/sludges including foul water and collect the same in closed container and depositing in earth pit of sufficient size and depth in any type of soil within the defence land where directed by Engr-in-Charge to a distance exc 250m and n.exc 500m, returning and filling in earth in excavated pit after complete disposal of scum /sludges chamber inlet and outlet pipe, MS rungs, septic tank cleaning with fresh water and applying one coat of bituminous paint on steel surfaces such as MS rungs handle, inlet and outlet pipes etc, and filling tank with fresh water upto level as directed, placing the RCC cover slab in position and set in CM (1:6) including cleaning the sewage line from last manholes to septic tank complete all as specified and as directed
2
-
-
M & L for cleaning of filter bed/ soakage well etc by removing the filter media into scum /sludges in foul position n.exc 1.6m deep and getting out complete all as specified and as directed.
1
-
-
M & L for loose filling with filter media aggregate (stone) of guage 40mm to 80mm in filter bed soakage pit/ well etc. complete all as specified and as directed.
1
-
-
M & L for cleaning the old serviceable filter bed media obtained from above and refilling in filter bed/ soakage pit well etc. with suitable filter media complete all as specified and as directed.
1
-
-
Cleaning of blockage manually by rodding, pumping, etc. and removing the deposited sludge/solid/liquid material, outside MD land, complete all as directed from the following: - (a) Water closet any description including trap and CI pipe line upto first manhole complete all as specified and as directed.
40
-
-
Description all as per Item No 33 above but:
(b) Floor trap/Nahani trap upto & including gully trap complete all as specified and as directed.
40
-
-
Description all as per Item No 33 above but :
(c) Pipe from gully trap upto first manhole (excluding gully trap) complete all as specified and as directed.
50
-
-
Demolition of concrete of any description and in any position not otherwise specifically provided for unreinforced concrete complete all as specified and directed.
3
-
-
Demolition of concrete of any description and in any position not otherwise specifically provided for reinforced concrete complete all as specified and directed.
1
-
-
Dismantling of cast iron or reinforced concrete drain pipes jointed in CM and taking out of trenches /walls of 100 mm (internal dia) if required all as specified and as directed.
16
-
-
Dismantling of cast iron or reinforced concrete drain pipes jointed in CM and taking out of trenches /walls of 150 mm (internal dia) if required all as specified and directed
16
-
-
M & L providing cement concrete (1:3:6) type C-1, (using 20mm graded stone aggregate) as in coping, benching, bed plate, including necessary form work complete all as specified and as directed.
2
-
-
M & L for precast RCC (1:2:4) type B-1,(using 20mm graded stone aggregate) as in cover slabs, manholes covers and similar article including necessary form work complete set in CM (1:4) all as specified and as directed.
Note : Reinforcement shall be measured and paid separately.
1
-
-
M & L for mild steel TMT bars 6 to 8mm dia in reinforcement, cut to length, bent to shape required including cranking and bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips all as specified and as directed.
60
-
-
Taking up or down old cast iron manhole cover and frame complete all as specified and directed.
2
-
-
S & F for cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing frames, manhole covers, fire and soot doors dampers, stop valve boxes, gate stops parts of ranges, balusters and similar articles n.exc.5 Kg each complete all as specified and as directed.
12
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles away site and rubbish off the premises complete all as specified and as directed.
40
-
-
M & L for non skid coloured ceramic tiles 300mm x 300mm x 7 to 8mm thick in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
25
-
-
M & L for glazed ceramic tiles 300mm x 200mm x 6 to 7mm thick in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including rendering / backing coat of 10mm thick cement plastered as bedding layer / screed bed on fair surfaces of brick in CM (1:3) to receive wall tiles all as specified and as directed.
13
-
-
S & F 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
15
-
-
S & F in repairs vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, chain and plug and porcelain stopper but including brackets, waste couplings 32mm dia, cutting for and pinning in ends of brackets or errecting stand complete all as specified and as directed.
8
-
-
S & F in repair, vitreous china squatting pan, orissa pattern, size 580 x 440mm white, with integral foot rests (excluding flushing cistern and flush type) with and including connection to trap, set in and including concrete but connection to flushing pipe, anti syphonage pipe etc., complete inlcuding making good to floor, connection to drain (or out going pipe) etc., complete all as specified and as directed.
3
-
-
S & F in repair European type WC (Pedestal Pattern) complete inlcuding pedestal pan and trap inlcuding connection to drain, flushing pipe, seat cover (excluding fixing bolt, flushing cistern complete all as spefcified and as directed.
3
-
-
S & F in repairs PVC valveless, syphonic action type flushing cistern, 10 litres, low level, white with inlet ball valve, float and handle including brackets complete all as specified and as directed.
10
-
-
Taking up or down steel water tubing and connection 15mm bore complete all as specified and as directed.
12
-
-
S & F steel tubes, medium grade 15mm bore galvanized with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed.
8
-
-
Refixing of old steel tubing obtaining from taking down and connections new or old position (walls, ceiling, floors etc.,) of 15mm bore complete all as specified and directed.
4
-
-
Taking up or down steel water tubing and connection 20mm bore complete all as specified and as directed.
12
-
-
S & F steel tubes, medium grade 20mm bore galvanized with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
8
-
-
Refixing of old steel tubing obtaining from taking down and connections in new or old position (wall, ceiling floors etc.,) of 20mm bore complete all as specified and directed.
4
-
-
S & F 32mm bore low density polythylene pipes (LDPE) of pressure rating 6 Kgf/cm2 laid in trenches complete all as specified and as directed.
6
-
-
S & F in repairs angle stop cock 15mm bore, fancy type, chromium plated (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or unions and fixed complete all as specified and as directed.
30
-
-
S & F in repairs bib tap 15mm bore, fancy type, cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly screwed for iron and fixed complete all as specified and directed.
30
-
-
S & F in repairs pillar taps fancy type, cast copper alloy, with capstan head as chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipes and fixed complete all as specified and directed.
20
-
-
S & F in repairs 32mm size waste couplings of PTMT (half or full threaded) minimum weight 32mm 45gms complete all as specified and directed.
20
-
-
S & F in repairs towel rail 450mm long of stainless steel fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 170gms) complete all as specified and as directed.
20
-
-
S & F in repairs swivel shower of PTMT any coloured for fixing with 15mm pipe (minimum weight 40gms) complete all as specified and as directed.
20
-
-
S & F in repairs shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour complete all as specified and as directed.
10
-
-
S & F PVC connections 15mm size 600mm long with PTMT nuts complete all as specified and as directed.
30
-
-
Taking down chowkats or frame with shutters (without taking off shutters from the frame), n.exc 1.5 Sqm each complete all as specified and as directed.
4
-
-
Taking down chowkats or frame with shutters (without taking off shutters from the frame), exc 1.5 Sqm but n.exc 4.0 Sqm each complete all as specified and as directed.
4
-
-
Taking down shutters of any description n.exc 1 Sqm each all as specified and as directed.
4
-
-
Taking down shutters of any description exc 1 Sqm and n.exc 2.0 Sqm each all as specified and as directed.
10
-
-
S & F for second class HW plain, straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed.
0.16
-
-
S & F 35mm thick, second class HW plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial veneers ; supplied and fitted to chowkat complete all as specified and as directed.
4
-
-
S & F for flush shutters, 25 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
4
-
-
S & F second class HW, 35mm thick glazed and skeleton shutters, open rebated and rebated and prepared to receive glass or gauge etc., without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for screwing glass / gauge etc., sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.24 (a) complete all as specified and directed.
4
-
-
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with 19 x 19mm MS square tube and 1.2mm wall thickness complete all as specified and as directed.
16
-
-
S & F solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with a solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either sides and as gap inserts for top and bottom rail paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as per specification and drawing complete all as specified and as directed.
6
-
-
S & F Stainless Steel butt hinges 100mm long, medium weight cold rolled, fixed to timber frame work of doors complete all as specified and as directed.
16
-
-
S & F Stainless Steel butt hinges 75mm long, medium weight cold rolled, fixed to timber frame work of doors complete all as specified and as directed.
16
-
-
S & F in repairs 150mm length mild steel ordinary rat tail rod of pattern helical springs including roller and roller plate complete all as specified and as directed.
6
-
-
S & F extruded aluminium alloy handles 150mm, fabricated type, anodized complete all as specified and as directed.
8
-
-
S & F extruded aluminium alloy handles 100mm, fabricated type, anodized complete all as specified and as directed.
4
-
-
S & F aluminium anodized barrel tower bolt of extruded section length of bolt 150mm complete all as specified and as directed.
8
-
-
S & F aluminium anodized barrel tower bolt of extruded section length of bolt 100mm complete all as specified and as directed.
4
-
-
S & F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of operature 1.40mm and fixed with aluminium wire staples all as specified and as directed.
16
-
-
S & F in repairs 12mm dia stainless steel curtain rail 12 mm dia fixing with all types of bracket to required length complete all as specified and directed. Note : Rate included for side bracket for fixing complete.
6
-
-
Hacking out old broken unserviceable glass panes (any thickness size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new one complete all as specified and as directed.
4.75
-
-
S & F 3mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 Sqm in each pane complete all as specified and as directed.
4.75
-
-
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed.
400
-
-
S & F 0.71 mm thick aluminium corrugated sheeting Alloy 31000 H4, STUCCO embossed finish with two corrugations side lap fixed with L-type or J-type hook and aluminium washer in roof with end laps complete all as specified and as directed.
40
-
-
S & F pre-painted corrugated galvalume (55% aluminium + 43.5% Zinc+ 1.5% Silicon) steel sheets as in roofing /wall cladding, 0.50mm thick (total coated thickness), conforming to AS-1397/ ASTM A-792 and having yield strength minimum 550 Mpa fixed with self drilling metal coated screw of appropriate size, self taping bolts and fixed as per manufacturers instructions complete all as specified and directed. (Note: The sheet shall be laid with one corrugation side lap and one end lap minimum 150mm all as per manufacturers instructions alongwith wind ties).
340
-
-
Description all as per Item No 91 above but plain galvalume sheet complete all as specified and as directed.
20
-
-
M & L for preparation of old painted surfaces of steel of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint to top exposed steel roofing sheets, complete all as specified and as directed.
590
-
-
Dismantling of wall panelling/ceiling (fibre, pulp, insulation etc) of any description of any thickness including cover fillets complete all as specified and as directed.
40
-
-
S & F aluminium anodised snap grid frame (with minimum 15 micron uniform anodic coating) size of 600 x 600 mm consisting of Tee / Angle section, size 40x40x2 mm thick as approved make conforming to IS-733 in frames of false ceiling including aluminium cleats with necessary CP brass / stainless shunk screws, aluminium perimeter angles fixed to wall wooden frame at centre to centre and fixing frame to level adjusting anchors 6 mm dia GI wire hook in Tee members at 1.5 m centre to centre fixed to steel truss or roof complete all as specified and as directed.
40
-
-
M & L for fixing in position 4 mm thick Non Asbestos designer ceiling board of size 595 x 595 mm as per manufacturer's specification complete all as specified and directed. Make: Everest /Ramco /Charminar ; Texture : Oceanic, Lake and Hill, Electra
40
-
-
S & F 12 mm thick prelaminated particle board interior grade both sides laminated complete all as specified and as directed.
10
-
-
M & L for RCC (1:2:4) (Nominal Mix) type B-1 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, platforms, lintels over and roof slab complete all as specified and as directed.
1
-
-
M & L for use and waste of timber as in form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for rough finished surfaces of concrete flat all as specified and as directed.
10
-
-
M & L for preparing old decorated ceiling surfaces of any description, complete all as specified and as directed.
200
-
-
M & L for complete removal of existing treatment and preparation of wall surfaces of any description, complete all as specified and as directed.
200
-
-
M & L for one coat of white washing on decorated wall surfaces of any description, complete all as specified and as directed.
500
-
-
M & L for one coat of white washing on decorated ceiling surfaces of any description, complete all as specified and as directed.
50
-
-
M & L for applying one coat of dry distemper on decorated wall surfaces of any description, complete all as specified and as directed.
600
-
-
M & L for applying one coat of distemper oil emulsion on decorated wall surfaces of any description, complete all as specified and as directed.
500
-
-
M & L for applying two coats of distemper oil emulsion on wall surfaces of any description complete all as specified and as directed.
60
-
-
M & L for applying one coat of cement based paint on decorated wall surfaces of any description complete all as specified and as directed.
5050
-
-
M & L for applying one coat of anti fungal acrylic emulsion on internal wall surfaces of any description complete all as specified and as directed.
1200
-
-
M & L for applying one coat of anti fungal exterior acrylic emulsion on wall surfaces of any description complete all as specified and as directed.
1200
-
-
M & L for applying one coat of synthetic enamel paint over old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including preparation of surfaces, complete all as specified and as directed.
350
-
-
M & L for applying one coat of synthetic enamel paint over old painted steel & iron surfaces including roof sheets and trusses etc of any description, not otherwise described over 10 cm width or girth, including preparation of surfaces, complete all as specified and as directed.
600
-
-
M & L for applying wall care putty, in two coats over a coat of alkali resistant cement based primer on wall surfaces & smoothening the surfaces with sand papers etc., complete all as specified and as directed.
600
-
-
Dismantling fencing wire mesh of any type complete all as specified and as directed.
8
-
-
Excavating soft/loose soil in post holes (or similar holes) each n.exc 0.5 Cu.m getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm watering and removing surplus soil to a distance exc 50m and making good the disturbed surface all as specified and as directed.
5
-
-
Supply only PVC vinyl coated GI chain link mesh of size 50mm x 50mm, 3.6mm GI wire with 1mm thick PVC vinyl coated all around complete all as specified and as directed.
15
-
-
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and as directed.
8
-
-
M & L mild steel TMT round bar 10 mm dia and over as in tightening of chain link fencing including cutting to shape, necessary drilling, bolting etc complete all as specified and as directed.
50
-
-
S & F 12mm dia mild steel rag or lewis bolts screwed one end with hexagonal or square nuts and washers at one end and secured the other or screwed the both ends each screwed ends to be fitted exc 10 cm and n.exc 15cm long all as specified and as directed.
4
-
-
S & F for CI soil/waste/vent pipes (sand cast) in any length with or without ears with cement joints, laid in trenches or in floor of 100mm dia complete all as specified and directed.
5
-
-
S & F for CI soil/waste/vent pipes (sand cast) in any length with or without ears with cement joints, laid in trenches or in floor of 150mm dia complete all as specified and directed.
5
-
-
S & F for CI soil/waste/vent pipes (sand cast) in any length with or without ears with cement joints, fixed with wall of 100 dia complete all as specified and directed.
3
-
-
S & F for CI soil/waste/vent pipes (sand cast) in any length with or without ears with cement joints, , laid in trenches or in floor of 100 dia but except pipe complete all as specified and directed.
3
-
-
S & F for CI soil/waste/vent pipes (sand cast) in any length with or without ears with cement joints, laid in trenches or in floor of 150 dia but except pipe complete all as specified and directed.
3
-
-
M & L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and completely surrounding pipes after they are laid and tested for 100 mm bore pipes complete all as specified and as directed.
7
-
-
M & L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and completely surrounding pipes after they are laid and tested for 150 mm bore pipes complete all as specified and as directed.
7
-
-
S & F CI cowls for bore of pipe 100mm complete all as specified and as directed.
3
-
-
S & F for CI bends (any radius) diminishing or tappers of 100mm bore pie (larger bore measured) complete all as specified and as directed.
3
-
-
M & L for non skid ceramic tiles 7 to 8mm thick (square/rectangular) area each tiles exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed or bedding layer of mortar in cement plaster 1:4 for laying finishes as specified and as directed.
5
-
-
M & L for non skid ceramic tiles 7 to 8mm thick (square/rectangular) area each tiles exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match as in vertical surface/skirting etc., laid over and including rendering 10mm thick cement plastered as bedding layer / screed bed on fair surfaces of brick in cement mortar (1:3) to receive wall tiles all as specified and as directed.
2
-
-
M & L for preparation of new or previously untreated wood surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (ordinary tint) over one coat of pink primer complete all as specified and as directed.
40
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements