To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date20 Feb 2024
Closing Date19 Mar 2024
Tender Amount₹ 43,00,000
Costs
EMD
₹ 86,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_643361_1Bid Award Id
ViewTender No
8375/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Demolition of precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer in charge
10
-
-
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer in charge
50
-
-
Removing loose and broken concrete/ masonary surface by chiseling/ mechanically etc from the roof slab, coloumn, beam and similar structural members cutting edges, cleaning the dismantled portion with wire brush etc to make the reinforcement naked and remove dust, dirt and other foreign particle etc and removig to debries 50 Mtr from site complete all as specified and as directed by Engineer in charge
20
-
-
M&L for applying IPH RB -107 polymer based rust-remover (pH value –12 ) and applying IPH RB -167 Polymer based rust preventive (pH value-9) to all exposed reinforced bars complete all as specified and as directed by Engineer in charge
20
-
-
M&L for applying one coat of epoxy bonding coat as per manufacture's instruction to bind with old concrete / wall surfaces of soffit of slab, coloumn, beam and similar structural members for new cement surface complete all as specified and as directed by Engineer in charge
20
-
-
M&L for applying polymer modified cement mortar rendering 15mm average thick in CM 1:3 on concrete surface duly mixing polymer modifier of make @ 10 Ltr per bag of cement or @ 5% by wt of cement finished even and smooth without using extra cement all as specified and as per manufacturer's instructions complete all as specified and as directed by Engineer in charge
20
-
-
M&L for double charge coloured vitrified tiles 10mm thick (square/rectangular) polished, area of each tile exc. 0.18 Sqm but not exc. 0.36 Sqm as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, laid over and including 20mm thick screed bed in cement mortar (1:6) complete all as specified and as directed by Engineer in charge
150
-
-
M&L for double charge coloured vitrified ceramic tiles of 10 mm thick as in vertical surface, pattern as approved by GE, set and jointed in neat cement slurry using grey cement and pointed in coloured cement to match the colour of tiles over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed by Engineer in charge
15
-
-
M&L for coloured Non-skid Ceramic tiles 7 to 8 mm thick exc. 0.11 sqm but n.exc 0.18 sqm area of each tiles in floor/ steps etc set and jointed in neat cement slurry and pointed in coloured cement to match as in floor over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed by Engineer in charge
10
-
-
M&L for coloured glazed ceramic tiles 450x300x 7mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing in cement mortar (1:4) complete all as specified and as directed by Engineer in charge
60
-
-
M&L for granite (of any type) 16 to 20 mm thick machine cut fixed on slab,window cill etc , bedded & jointed with grey cement slurry & pointed with white cement with admixure of pigment to match the shade of granite stone including cutting, moulding & polishing over and including 20 mm thick screed in CM (1:4) complete all as specified and as directed by Engineer in charge
25
-
-
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer in charge
30
-
-
M & L for 25 mm thick, PCC 1:2:4, Type B-0, (using 12.5mm graded aggregate) as in Sub base for flooring/levelling coarse etc complete all as specified and as directed by Engineer in charge
120
-
-
M&L for precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and as directed by Engineer in charge
2
-
-
M & L for rendering to concrete or block masonry surfaces or surfaces other than fair faces of brick surfaces, 10mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer in charge
50
-
-
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6(Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and fair complete all as specified and as directed by Engineer in charge
Note: Water proofing compound will be measured and paid separately.
50
-
-
M & L rendering 5mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer in charge
20
-
-
Supply only Integral water proofing compound complete all as specified and as directed by Engineer in charge
15
-
-
Material and labour for complete removal of existing treatment and applying one coat of white cementitious putty on wall and making the surfaces smooth by rubbing with sand paper to achieve finished surface complete all as specified and as directed by Engineer in charge
200
-
-
M&L for preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge
50
-
-
M&L for preparing newly plastered surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge
20
-
-
M & L for complete removel of existing treatment on ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge
20
-
-
Taking up or down 15mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge
30
-
-
Taking up or down 20 mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge
20
-
-
Taking up or down 25 mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge
5
-
-
Supply and laying of CPVC pipes 20 mm dia outer boreSDR 11 &plain CPVC SDR 11with all special fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in charge
50
-
-
Supply and laying of CPVC pipes 25mm dia outer boreSDR 11 &plain CPVC SDR 11 with all special fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in charge
5
-
-
Supply and fixing 20 mm outer dia CPVC Male Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge
5
-
-
Supply and fixing 25 mm outer dia CPVC Male Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge
1
-
-
Supply and fixing 20 mm outer dia CPVC pipes brass Elbow complete all as specified and as directed by Engineer in charge
9
-
-
Supply and fixing 20mm outer dia CPVC pipes brass Elbow (3/4 X1/2) complete all as specified and as directed by Engineer in charge
4
-
-
Supply and fixing 20mm outer dia CPVC female brass adaptor complete all as specified and as directed by Engineer in charge
7
-
-
Supply and fixing 25 mm outer dia CPVC female brass adaptor complete all as specified and as directed by Engineer in charge
2
-
-
Supply and fixing 25 mm outer dia tank Adaptor complete all as specified and as directed by Engineer in charge
1
-
-
Supply and fixing 20mm outer dia union complete all as specified and as directed by Engineer in charge
2
-
-
Supply and fixing 25 mm outer dia union complete all as specified and as directed by Engineer in charge
1
-
-
Supply and fixing 20 mm outer dia Brass Tee complete all as specified and as directed by Engineer in charge
10
-
-
S & F in repairs Pillar Taps, Chromium Plated,15 mm dia quarter turn fixed to pipe complete all as specified and as directed by Engineer in charge
8
-
-
S&F in repairs angular stop cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by Engineer in charge
2
-
-
S&F in repairs bib tap cast copper alloy fancy type chromium plated screwed for 15mm bore complete all as specified and as directed by Engineer in charge
5
-
-
S&F vitreous china counter top wash hand basin, white colour of size 500x435x180mm including fixing on granite slab 32 mm waste coupling brass chromium plated suitable for wash hand basin with long screw shank and fly nuts & PVC waste pipe & including 15mm chromium plated pillar tap complete all as specified and as directed by Engineer in charge
2
-
-
S&F Vitreous China wash down water closet pan (pedestal pattern) of size 380x610x805mm Rimless bowl with cistern for coupled, WC with UF soft close slim seat cover hinges, dual flush cistern fitting, conversion bend , fixing accessories and accessories set including 32 mm pvc waste pipe complete all as specified and as directed by Engineer in charge
1
-
-
S&F PVC flexible connection with PTMT nuts, of 15mm dia and 600mm long with brass unions and rubber washers on either side, for connecting water supply line to WHB, flushtank ,Geyser etc complete all as specified and as directed by Engineer in charge
2
-
-
S&F in repair stainless steel sink with drainage board made out of 1.00 mm thick sheet with plug, washers, Ms angle cantilever brackets for suitable size and connecting union to pipe of overall size 915mm x 460 mm and bowl size 410mm x 330 mm x 160 mm including 40 mm pvc waste pipe & waste coupling complete all as specified and as directed by Engineer in charge
1
-
-
Dismantling of cast iron or reinforced concrete / PVC (SWR) drain pipes of size 75/100 mm dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed by Engineer in charge
35
-
-
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in down pipes complete all as specified and as directed by Engineer in charge
15
-
-
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer in charge
10
-
-
S & F 75 in repairs mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed by Engineer in charge
5
-
-
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed by Engineer in charge
4
-
-
S&F PVC (SWR) bends with access door 75mm dia complete all as specified and as directed by Engineer in charge
2
-
-
S&F 75mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed by Engineer in charge
1
-
-
S & F 75mm dia out let, PVC (SWR) Floor Trap with SS grating including jointing to waste pipe fixed with solvent cement complete all as specified and as directed by Engineer in charge
3
-
-
S & F Grating doom 125 mm dia with chrome plate all as complete all as specified and as directed by Engineer in charge
3
-
-
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by Engineer in charge
20
-
-
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in floors complete all as specified and as directed by Engineer in charge
5
-
-
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed by Engineer in charge
10
-
-
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed by Engineer in charge
2
-
-
M &L for Stack clamps for 75mm dia bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts andsecuring ends of stays to wall or roof complete all as specified and as directed by Engineer in charge
10
-
-
M &L for Stack clamps for 110 mm dia bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts andsecuring ends of stays to wall or roof complete all as specified and as directed by Engineer in charge
10
-
-
S&F PVC (SWR) bends with access door 110mm dia complete all as specified and as directed by Engineer in charge
5
-
-
S&F 110mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed by Engineer in charge
2
-
-
Taking down chowkats or frames not exceeding 1.5 Sqm (with shutters & grill (if fixed) without taking off shutters from the frame) complete all as specified and as directed by Engineer in charge
5
-
-
Taking down chowkats or frames exc 1.5 Sqm and not exceeding 4 Sqm (with shutters and grill (if fixed) without taking off shutters from the frame) complete all as specified and as directed by Engineer in charge
6
-
-
Taking down shutters of any description opening exc 2 Sqm each and removing from site complete all as specified and as directed by Engineer in charge
5
-
-
S&F Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer in charge
300
-
-
S & F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed by Engineer in charge
90
-
-
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
120
-
-
Supply only 4 mm Plain sheet glass ordinary quality ,in square exc 0.5 sqm each complete all as specified and as directed by Engineer in charge
50
-
-
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer in charge
50
-
-
S & F in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer in charge
10
-
-
S & F only Figured glass 4 mm,pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and as directed by Engineer in charge
1.8
-
-
Refixing shutter of any description not exceeding 1 Sqm in the same location complete all as specified and as directed by Engineer in charge
5
-
-
S & F 4 mm Plain sheet glass ordinary quality ,in square exc 0.5 sqm each complete all as specified and as directed by Engineer in charge
30
-
-
Cutting holes in stone walls built in cement mortar for inserting hold fast/lugs & making good disturbed portion in CM 1:3 or cement congrete 1:2:4, type B-1 as required (Depth of embedded portion of hold fasts orings measured from the face of the jamb into wall exc half brick but no exc one brick complete all as specified and as directed by Engineer in charge
30
-
-
S & F Oral lay in plain aluminium ceiling system consisting of 600 x 600 mm ties of 0.6/0.7 mm thickness in white colour laid over pre-coated aluminium sections white colour 15mm wide T section flanges having sticthing on the main runner, 1200mm and 600mm cross T's with web height of 43mm and a load carrying capacity of 23.71 Kg/Sqm having galvanisation of 120gram/sqm, with ties having resistance (RH) of 100%, fire performances A2-S1, Do in module of size 600x600 with acoustic lining, suitable for green building applications with re-cycled content of 50% including 8mm PVC laminated board/ceiling tiles & including dismantling old ceiling board complete all as specified and as directed by Engineer in charge
150
-
-
S & F in repair 18 to 20mm thick prelaminated HDF panels of interior grade type-II with melamine finish of approved shade for kitchen cabin/wardrobe/wall panelling fixing with necessary fitting like keku fitting,spring clip,hanger plate,modular hinge/clip,push fix or stud fitting as per manufacturers instructions complete all as specified and as directed. Make:M/s Action TESA or equivalent as approved protected shutters,HDF board in kitchen bottom cubboard shelf complete including removal of old cup board/ kitchen shelves any type complete all as specified and as directed by Engineer in charge
50
-
-
S&F 30mm width continuous (piano) hinges mild steel finish or electrogalvanised complete all as specified and as directed by Engineer in charge
25
-
-
Supply and fix for brass locks, cupboard, grade 1, 75mm size, 4 levers with duplicate keys with brass key hole complete all as specified and as directed by Engineer in charge
10
-
-
S&F stainless steel auto closing heavy duty modular hinges of size 103 x 64mm for cupboard shutters complete all as specified and as directed by Engineer in charge
30
-
-
S&F 100mm stainless steel handles for cupboard shutters complete all as specified and as directed by Engineer in charge
20
-
-
M&L Mild steel work of angle, channel plates etc as in framed roof truss , purlins brackets etc including bending and welding angles,bolts as necessary, gusset plates, riveting, etc , conforming to Fe 290 Gde-E-165 complete all as specified and as directed by Engineer in charge
300
-
-
M & L for preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer in charge
20
-
-
M&L for taking down carefully existing aluminium point wiring (light, fan , socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etc complete all as specified and as directed by Engineer in charge
212
-
-
M&L for taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and as directed by Engineer in charge
215
-
-
M&L for taking down carefully existing old DBs and making good disturbed surfaces of walls to match the existing surfaces complete all as specified and as directed by Engineer in charge
8
-
-
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium grade/PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered GI metal flush box and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and as directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.)
Note: The quoted rate inclusive for the following :- (a) Modular cover plate with frame of any module complete.
(b) Proper colour coding is to be followed as per IS Specification. (c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement complete all as specified and as directed by Engineer in charge
-
-
-
One light point controlled by one switch.
54
-
-
One ceiling fan/exhaust fan/wall fan point controlled by one switch.
27
-
-
One 3 pin socket outlet 5 Amps on the same board with other switches
8
-
-
One 3 pin socket outlet 5 Amps independent.
46
-
-
All as per item No 89.00 above but cable with 2.5 sqmm for socket outlet 15 amps independent complete all as specified and as directed by Engineer in charge
68
-
-
All as per item No 89.00 above but cable with 4.0 sqmm for metal plug and socket complete all as specified and as directed by Engineer in charge
9
-
-
M & L for submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including takind down unserviceable submain wiring complete all as specified and as directed by Engineer in charge
Note : (i) Three run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length.
75
-
-
M & L for submain wiring with four single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and two single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including takind down unserviceable submain wiring complete all as specified and as directed.
Note : (i) Six run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length.
60
-
-
M & L for submain wiring with four single core PVC insulated unsheathed multistranded copper conductor cable of size 10 sqmm (FRLSH) and two single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 10 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including takind down unserviceable submain wiring complete all as specified and as directed.
Note : (i) Six run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length.
80
-
-
Supply & fixing modular switch one way, 6 Amps, 1 module, 240 volts complete all as specified and as directed by Engineer in charge
135
-
-
Supply & fixing modular switch one way, 16 Amps, 1 module, 240 volts complete all as specified and as directed by Engineer in charge
68
-
-
Supply & fixing modular socket, 2/3 pin, 6 amps, 2 module complete all as specified and as directed by Engineer in charge
54
-
-
Supply & fixing modular socket, 2/3 pin, 6/16 amps, 2 module complete all as specified and as directed by Engineer in charge
68
-
-
Supply & fixing modular metal flush box 3 module complete all as specified and as directed by Engineer in charge
122
-
-
Supply & fixing modular metal flush box 4 module complete all as specified and as directed by Engineer in charge
2
-
-
Supply & fixing modular metal flush box 6 module complete all as specified and as directed by Engineer in charge
10
-
-
Supply & fixing modular metal flush box 8 module complete all as specified and as directed by Engineer in charge
10
-
-
Supply & fixing modular cover plate with frame 3 module complete all as specified and as directed by Engineer in charge
122
-
-
Supply & fixing modular cover plate with frame 4 module complete all as specified and as directed by Engineer in charge
2
-
-
Supply & fixing modular cover plate with frame 6 module complete all as specified and as directed by Engineer in charge
10
-
-
Supply & fixing modular cover plate with frame 8 module complete all as specified and as directed by Engineer in charge
10
-
-
Supply & fixing ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engineer in charge
81
-
-
Supply & fixing in repair LED lights fitting 1x 20W, 2000lm, CDL, surge protection of 2 KV, 4 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer in charge
26
-
-
Supply & fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 1000lm, CDL, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer in charge
2
-
-
Supply and fixing in repair LED luminaire 600 mm x 600 mm 40 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer in charge
Notes for item No 112 to 114 : (i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C
(xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more
( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .
(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .
(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
26
-
-
Supply & fixing exhaust fan metal body, AC, single phase, 230V, 300mm sweep complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan including making good disturbed surface with existing wall colour and provision of cable from ceiling rose/connector to fan including taking down old unserviceable exhaut fan and deposited to MES store yard complete all as specified and as directed by Engineer in charge
2
-
-
Supply & fixing ceiling fan 1200mm sweep with blades, suitable BLDC remote electronic regulator as per OEM design, down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated, equipped with brushless direct current motor (BLDC) of wattage 28W including provision of cable from ceiling rose/connector to fan including taking down old unserviceable exhaust fan and deposited to MES store yard complete all as specified and as directed by Engineer in charge
15
-
-
Supply & fixing Wall mounted fan 400mm sweep with blades, mounting accessories kit, blade guard set, guard ring, AC 230V complete all as specified and as directed by Engineer in charge
10
-
-
Supply and fixing MCCB DB VTPN 4 way IP-54, IK-09 made of sheet steel phos phatised, powder painted with copper bus bar 250A, neutral link, earth bar and Din rail 415 Volts with double door, suitable for MCCB 4 Pole 200 Amps as incomer and MCB Single Pole as outgoing complete all as specified and as directed by Engineer in charge
2
-
-
Supply & fixing in replacement sheet metal enclosure with TPN MCB DB's 4 way (grouted in walls) double door type IP-54, IK-09 Protection. Isolated Neutral,Door earthing, cement spill protector complete including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and as directed by Engineer in charge
3
-
-
Supply & fixing MCB DB's SPN 8 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 200 amps rated copper busbar including suitable size of copper ferrules for fixing of cable complete all as specified and as directed by Engineer in charge
Note for item srl No 118 to 120 : (i) MCCB and MCB will be measured and paid separately.
(ii) The cost for flushing of Distribution box in any type of wall and making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate
3
-
-
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and as directed by Engineer in charge
9
-
-
Supply and fixing in repair MCCB 4 Pole, 415V, thermal adjustable type, 160 Amps with breaking capacity 25 KA, ICS = 100% ICU, complete all as specified and as directed by Engineer in charge
2
-
-
Supply and fixing MCCB 4 pole, thermal adjustable type, 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA ICS = 100% ICU, complete all as specified and as directed by Engineer in charge
1
-
-
Supply & fix in repair MCB TPN 40 to 63 Amp, C series, 415V, 10 KA complete all as specified and as directed by Engineer in charge
4
-
-
Supply and fixing in repair MCB SPN 40 to 63 Amps ,10 KA, C Curve, 230 Volts, 50 HZ complete all as specified and as directed by Engineer in charge
4
-
-
Supply and fixing in repair MCB SP 6-32 Amps ,10 KA, B Curve, 230 Volts, 50 HZ complete all as specified and as directed by Engineer in charge
84
-
-
Supply and fixing PVC insulated, sheathed two core aluminium conductor 16 sqmm complete all as specified and as directed by Engineer in charge
50
-
-
M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers etc connected to DBs all as shown in electrical plate No.5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation / earth work in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade,including GI earth strip 32 x 6mm size with GI protection pipe of 15 mm medium grade up to 7.5 meter length etc complete all as specified and as directed by Engineer in Charge Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item
(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete
2
-
-
Supply and install hi wall split AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2.0 TR complete all as specified and as directed by Engineer in charge
3
-
-
Supply and install hi wall split AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.5 TR complete all as specified and as directed by Engineer in charge
Note for item Nos 125 & 126 : (a) The cost of copper tubing of any length from indoor to outdoor unit, remote with batteries, refrigerant gas, compressor oil, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate.
(b) Drilling of the wall should be done by core cutting machine.
2
-
-
M&L for air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete all as specified and as directed by Engineer in charge
5
-
-
Supply and fixing Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed by Engineer in charge
5
-
-
Supply, install, testing and commissioning of voltage stabilizer copper wound of capacity 5 KVA, automatic operation, single phase naturally air cooled indoor type, wall mounted triple boost type and designed for input variation between 170 volt to 270 volt AC with output voltage stabilised at 230 volt AC, 50 HZ with accuracy +/- 2.5% and with inbuilt digital display for showing voltage/amps of incoming and outgoing with selector switch with TDR of 2 to 3 minutes and high and low voltage cutoff complete all as specified and as directed by Engineer in charge
2
-
-
All as per item No 133.00 above but voltage stabilizer copper wound of capacity 4 KVA complete all as specified and as directed by Engineer in charge
3
-
-
Supply and fixing Rigid non-metallic PVC conduit 25 mm dia heavy duty inclusive of all fittings and fixing accessories complete all as specified and as directed by Engineer in charge
70
-
-
M&L for taking down existing Split AC unit 1.5/2/ ton capacity carefully by disconnecting existing electrical connection, removing aside, servicing by using blower/soap water for making dust free to the complete unit and applying lubricants to all the moveable parts and replacement of worn out bolts, nuts washers, split pin,remote battries etc at site and reassembling & fixing back their original position including testing complete all as specified and as directed by Engineer in charge
7
-
-
Supply only Regrigerant gas R-32 in manufacturer's sealed cylinder complete all as specified and as directed by Engineer in charge
(i) Empty cylinder shall be returned to the contractor.
(ii) Payment shall be made for net weight of gas.
7
-
-
Evaluation Notes How It Works ?