Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date24 Apr 2024
Closing Date6 Jun 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_651006_1Bid Award Id
ViewTender No
8469ATender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per item No 3.00 herein before but two coat of oil bound distemper on ceiling.
1250
-
-
M & L for two coats of weather proof exterior acrylic emulsion paint with anti fungal property over a coat of primer on old painted wall surfaces including preparation of surfaces by complete removal of existing treatment of any description complete all as specified and as directed.
6000
-
-
M & L for one coat of wheather proof exterior acrylic emulsion paint with anti fungal property on old painted wall surfaces including preperation of surfaces all as specified and directed.
6000
-
-
M & L for one coat of synthetic enamel paint of old painted wood/wooden based surfaces exceeding 10 cm width or girth including preparation of surfaces complete all as specified and directed.
1150
-
-
M & L for one coat of synthetic enamel paint of old painted steel surfaces over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
700
-
-
M & L Writing letters or figurs (Block, Roman, Italic or Indian) n exc 30 cm high including stops, commas, short lines, dashes, hyphens, brackets including preparation of surfaces complete all as specified and as directed.
55
-
-
M & L for preparation of old wall surfaces and applying one layer of internal wall putty, complete all as specified and as directed. (Make: Birla / JK wall putty or equivalent)
690
-
-
Complete removal of existing treatment by scrapping with mechanical wall sander (having Mechanical vaccum mechanism) having RPM not less than1500, sanding pad of 80 grit haning dia of 7"/9" to make the surface free from dust, loose paint etc by skilled labour complete all as specified and directed.
500
-
-
M&L for single component polymer modified repair mortar with compressive strength minimum 38 MPA at 28 days (ASTM C 109:99) and tensile strength minimum 2.5 Mpa (ASTM C 307) up to 15mm in a single coat @ 34 kg per sqm for 15mm thickness as per manufacturer instructions complete all as directed.
50
-
-
M&L for waterproof cement based putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface.
200
-
-
M&L for one coat of acrylic waterbased interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface for painting of subbsequent coats.
200
-
-
M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
150
-
-
M&L for two coats of smooth interior acrylic emulsion with rich matt finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 ltrs(unndiluted) /10 sq mtrs diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint as per manufacturer instructions complete all as directed.
50
-
-
M&L for two coats of smooth interior acrylic emulsion with Texture finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 ltrs(unndiluted) /10 sq mtrs diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint as per manufacturer instructions complete all as directed.
50
-
-
M&L for one coat of acrylic water based exterior grade primer @0.9 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.
50
-
-
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
50
-
-
M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.
500
-
-
Material and labour for Washing, rubbing down and stopping of old distemper and painted surfaces of walls complete and applying one coat of cement base paint including preparation of old surface of walls all as specified and directed.
500
-
-
All as per item No 21.00 herein before but one coat of cement base paint on ceiling.
100
-
-
M & L for one coat of synthetic enamel paint of old painted steel surfaces n.exc 10cm in width or including preparation of surfaces complete all as specified and directed.
35
-
-
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water, etc all as specified and as directed.
400
-
-
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finishing the surface even and smooth without using extra cement, complete all as specificed and as directed.
150
-
-
M & L for rendering 5mm thick in CM (1:3) on fair faces of brick or concrete surfacesas in soffits of slabs, ceilings finished smooth and even without using extra cement complete all as specified and as directed
100
-
-
M&L for rendering 5mm thick in CM (1:4) mixed with water proofing compound over 10mm thick in CM (1:6) on external surfaces of block masonry and finishing the surface even and smooth without using extra cement, complete all as specificed and as directed. (Note : Supply only WPC shall be measured & paid separately)
150
-
-
Supply only water proofing compound, conforming to IS-2645 1975.
30
-
-
M & L for two coats of oil bound distember over one coat of alkali resistant primer including preparation of newly plastered surfaces of wall complete all as specified and as directed
150
-
-
All as per item No.29 above but as in ceilings/soffits of slab
120
-
-
M& L for two coat of wheather proof exterior acrylic emulsion paint with anti fungal property over a coat of primer on newly plastered wall surfacesincluding preperation of surface etc complete all as specified and directed by Engineer-in-Charge.(Make Apex Ultima)
150
-
-
Cutting of small trees/plants at the stem and removal of the roots of plants by using acids, chemical/Burning with blow lamp, cutting around the sport for removing the roots of any size and making good with Cement mortar 1:3 including two coats of cement base paint/acrylic emulsion up to height 4 story complete all as directed.
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements